Myocardial fiber length mapping with MR diffusion tensor imaging

被引:1
|
作者
Wu, Y. [1 ]
Wu, E. X. [1 ]
Wong, K. K. [1 ]
Tang, H. [1 ]
Tse, H. F. [1 ]
Lau, C. P. [1 ]
Yang, E. S. [1 ]
机构
[1] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Hong Kong, Peoples R China
来源
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7 | 2005年
关键词
D O I
10.1109/IEMBS.2005.1616118
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diffusion tensor MRI is emerging as a rapid, nondestructive method to map myocardial fiber organization. A precise biological description of myocardial fiber performance requires knowledge of four variables: length, force, velocity and time. However, study of quantification of myocardial fiber length is lacking. The current study aims to show myocardial fiber length maps of formalin-fixed heats. Diffusion tensor MRI with medium diffusion resolution (15 directions) was performed in one isolated pig heart. Fiber length maps were investigated in multiple short-axis slices. The results provide supplementary information of myocardial fiber organization. To our knowledge, the present study is the first report of the myocardial fiber length mapping.
引用
收藏
页码:7004 / 7007
页数:4
相关论文
共 50 条
  • [1] Myocardial fiber orientation mapping via MR diffusion tensor imaging
    Hsu, EW
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1169 - 1170
  • [2] MR Study of Myocardial Fiber Structure Using Diffusion Tensor Imaging
    Wu, Yin
    Wu, Ed X.
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 271 - 275
  • [3] Myocardial fiber orientation mapping using reduced encoding diffusion tensor imaging
    Hsu, EW
    Henriquez, CS
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2001, 3 (04) : 339 - 347
  • [4] Measuring and mapping cardiac fiber and laminar architecture using diffusion tensor MR imaging
    Helm, P
    Beg, MF
    Miller, MI
    Winslow, RL
    COMMUNICATIVE CARDIAC CELL, 2005, 1047 : 296 - 307
  • [5] Diffusion tensor MR imaging and fiber tractography: Technical considerations
    Mukherjee, P.
    Chung, S. W.
    Berman, J. I.
    Hess, C. P.
    Henry, R. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (05) : 843 - 852
  • [6] Diffusion tensor MR imaging and fiber tractography: Theoretic underpinnings
    Mukherjee, P.
    Berman, J. I.
    Chung, S. W.
    Hess, C. P.
    Henry, R. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (04) : 632 - 641
  • [7] MR diffusion tensor imaging
    Secca, M. Forjaz
    COMPUTATIONAL MODELLING OF OBJECTS REPRESENTED IN IMAGES: FUNDAMENTALS, METHODS AND APPLICATIONS, 2007, : 39 - 43
  • [8] Diffusion Tensor MR Imaging
    Rovaris, Marco
    Agosta, Federica
    Pagani, Elisabetta
    Filippi, Massimo
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2009, 19 (01) : 37 - +
  • [9] Fiber orientation mapping using generalized diffusion tensor imaging
    Özarslan, E
    Vemuri, BC
    Mareci, TH
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, 2004, : 1036 - 1039
  • [10] Basic Concepts of MR Imaging, Diffusion MR Imaging, and Diffusion Tensor Imaging
    de Figueiredo, Eduardo H. M. S. G.
    Borgonovi, Arthur F. N. G.
    Doring, Thomas M.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2011, 19 (01) : 1 - +