Commissural Alignment With New-Generation Self-Expanding Transcatheter Heart Valves During Aortic Replacement

被引:7
作者
Buono, Andrea [1 ]
Morello, Alberto [2 ]
Pero, Gaetano [1 ]
Corcione, Nicola [2 ]
Bettari, Luca [1 ]
Saccocci, Matteo [3 ]
Villa, Emmanuel [3 ]
Biondi-Zoccai, Giuseppe [4 ,5 ]
Giordano, Arturo [2 ]
Maffeo, Diego [1 ]
机构
[1] Fdn Poliambulanza Ist Osped, Cardiovasc Dept, Intervent Cardiol Unit, Via Bissolati 57, I-25124 Brescia, Italy
[2] Pineta Grande Hosp, Unita Operat Interventist Cardiovasc, Via Domitiana Km 30-00, I-81030 Castel Volturno, Italy
[3] Fdn Poliambulanza Ist Osped, Dept Cardiothorac Surg, Brescia, Italy
[4] Sapienza Univ Rome, Dept Med Surg Sci & Biotechnol, Latina, Italy
[5] Mediterranea Cardioctr, Naples, Italy
关键词
Transcatheter aortic valve replacement; Self-expanding transcatheter heart valve; Commissural alignment; Coronary obstruction; IMPLANTATION;
D O I
10.1016/j.carrev.2021.07.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Preserving coronary artery access is a crucial goal during transcatheter aortic valve replacement (TAVR) procedures, especially in case of self-expandable transcatheter heart valve (SE-THV) implantation. In this light, a proper commissural alignment is needed to avoid the risk of coronary obstruction and to permit easy vessels re-cannulation for diagnostic and interventional purposes. New-generation SE-THVs have been furnished of different markers, able to guide operators to perform a correct commissural alignment. In this case series, we describe key procedural aspects of commissural alignment for the different available SE-THVs, providing a stepby-step tutorial for each device. Lastly, we illustrate a commissural alignment in a contrast-zero TAVR. (c) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:S139 / S143
页数:5
相关论文
共 12 条
[1]   Coronary Cannulation After Transcatheter Aortic Valve Replacement The RE-ACCESS Study [J].
Barbanti, Marco ;
Costa, Giuliano ;
Picci, Andrea ;
Criscione, Enrico ;
Reddavid, Claudia ;
Valvo, Roberto ;
Todaro, Denise ;
Deste, Wanda ;
Condorelli, Antonio ;
Scalia, Matteo ;
Licciardello, Alessandra ;
Politi, Giorgia ;
De Luca, Giuseppe ;
Strazzieri, Orazio ;
Motta, Silvia ;
Garretto, Valeria ;
Veroux, Pierfrancesco ;
Giaquinta, Alessia ;
Giuffrida, Angelo ;
Sgroi, Carmelo ;
Leon, Martin B. ;
Webb, John G. ;
Tamburino, Corrado .
JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (21) :2542-2555
[2]   Baseline, procedural and outcome features of patients undergoing transcatheter aortic valve implantation according to different body mass index categories [J].
Corcione, Nicola ;
Testa, Alberto ;
Ferraro, Paolo ;
Morello, Alberto ;
Cimmino, Michele ;
Albanese, Michele ;
Giordano, Salvatore ;
Bedogni, Francesco ;
Iadanza, Alessandro ;
Berti, Sergio ;
Regazzoli, Damiano ;
Trani, Carlo ;
Pepe, Martino ;
Frati, Giacomo ;
Biondi Zoccai, Giuseppe ;
Giordano, Arturo .
MINERVA MEDICA, 2021, 112 (04) :474-482
[3]   A patient-specific algorithm to achieve commissural alignment with Acurate Neo: The sextant technique [J].
De Marco, Federico ;
Casenghi, Matteo ;
Spagnolo, Pietro ;
Popolo Rubbio, Antonio ;
Brambilla, Nedy ;
Testa, Luca ;
Bedogni, Francesco .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (06) :E847-E854
[4]   Comparison of ProGlide vs. Prostar in patients undergoing transcatheter aortic valve implantation [J].
Giordano, Arturo ;
Corcione, Nicola ;
Ferraro, Paolo ;
Morello, Alberto ;
Conte, Sirio ;
Testa, Luca ;
Iadanza, Alessandro ;
Sardella, Gennaro ;
Mancone, Massimo ;
Berti, Sergio ;
Petronio, Anna S. ;
Romagnoli, Enrico ;
Pepe, Martino ;
Frati, Giacomo ;
BIONDI-ZOCCAI, Giuseppe .
MINERVA CARDIOANGIOLOGICA, 2019, 67 (06) :443-449
[5]   Comparative one-month safety and effectiveness of five leading new-generation devices for transcatheter aortic valve implantation [J].
Giordano, Arturo ;
Corcione, Nicola ;
Ferraro, Paolo ;
Morello, Alberto ;
Conte, Sirio ;
Testa, Luca ;
Bedogni, Francesco ;
Iadanza, Alessandro ;
Berti, Sergio ;
Regazzoli, Damiano ;
Romagnoli, Enrico ;
Trani, Carlo ;
Burzotta, Francesco ;
Pepe, Martino ;
Frati, Giacomo ;
Biondi-Zoccai, Giuseppe ;
Tamburino, Corrado ;
Ettori, Federica ;
Petronio, Anna Sonia ;
Rinaldi, Mauro ;
Klugmann, Silvio ;
Rubino, Paolo ;
Tremoli, Elena ;
Marchese, Alfredo ;
Sardella, Gennaro ;
Pistis, Gianfranco ;
Brscic, Elvis ;
Giudice, Pietro ;
Piatti, Luigi ;
Ardissino, Diego ;
Indolfi, Ciro ;
Chiarella, Francesco ;
Tespili, Maurizio ;
De Servi, Stefano ;
Bonmassari, Roberto ;
Fappani, Antonio ;
Cuccia, Claudio ;
Cremonesi, Alberto ;
Tomai, Fabrizio .
SCIENTIFIC REPORTS, 2019, 9 (1)
[6]   Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients [J].
Mack, M. J. ;
Leon, M. B. ;
Thourani, V. H. ;
Makkar, R. ;
Kodali, S. K. ;
Russo, M. ;
Kapadia, S. R. ;
Malaisrie, S. C. ;
Cohen, D. J. ;
Pibarot, P. ;
Leipsic, J. ;
Hahn, R. T. ;
Blanke, P. ;
Williams, M. R. ;
McCabe, J. M. ;
Brown, D. L. ;
Babaliaros, V. ;
Goldman, S. ;
Szeto, W. Y. ;
Genereux, P. ;
Pershad, A. ;
Pocock, S. J. ;
Alu, M. C. ;
Webb, J. G. ;
Smith, C. R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (18) :1695-1705
[7]   Transfemoral transcatheter aortic valve replacement without contrast medium using the Medtronic CoreValve system: a single center experience [J].
Maffeo, Diego ;
Bettari, Luca ;
Latib, Azeem ;
Maiandi, Cristian ;
Villa, Emmanuel ;
Messina, Antonio ;
Saccocci, Matteo ;
Arneri, Andrea ;
Cuccia, Claudio ;
Troise, Giovanni .
JOURNAL OF CARDIOVASCULAR SURGERY, 2020, 61 (04) :489-495
[8]   The best way to transcatheter aortic valve implantation: From standard to new approaches [J].
Morello, Alberto ;
Corcione, Nicola ;
Ferraro, Paolo ;
Cimmino, Michele ;
Pepe, Martino ;
Cassese, Mauro ;
Frati, Giacomo ;
Biondi-Zoccai, Giuseppe ;
Giordano, Arturo .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 322 :86-94
[9]   Accurate commissural alignment during ACURATE neo TAVI procedure. Proof of concept [J].
Redondo, Alfredo ;
Valencia-Serrano, Felix ;
Santos-Martinez, Sandra ;
Raul Delgado-Arana, Jose ;
Barrero, Alejandro ;
Serrador, Ana ;
Gutierrez, Hipolito ;
Sanchez-Lite, Israel ;
Sevilla, Teresa ;
Revilla, Ana ;
Baladron, Carlos ;
Kim, Won-Keun ;
Carrasco-Moraleja, Manuel ;
Alberto San Roman, J. ;
Amat-Santos, Ignacio J. .
REVISTA ESPANOLA DE CARDIOLOGIA, 2022, 75 (03) :203-212
[10]   Transcatheter aortic valve neo-commissure alignment with the Portico system [J].
Tagliari, Ana Paula ;
Vicentini, Luca ;
Zimmermann, Jan Michael ;
Miura, Mizuki ;
Ferrari, Enrico ;
Perez, Daniel ;
Haager, Philipp K. ;
Jorg, Lucas ;
Maisano, Francesco ;
Taramasso, Maurizio .
EUROINTERVENTION, 2021, 17 (02) :E152-+