Cerebral oxygen saturation monitoring in preeclamptic pregnant women undergoing cesarean section with spinal anesthesia: a prospective, observational study

被引:2
作者
Karademir, Ali [1 ]
Kayhan, Gulay Erdogan [2 ]
机构
[1] Silopi Publ Hosp, Dept Anesthesiol & Reanimat, Sirnak, Turkey
[2] Eskisehir Osmangazi Univ, Fac Med, Dept Anesthesiol & Reanimat, TR-26480 Meselik Yerleskesi, Eskisehir, Turkey
关键词
Cesarean section; Anesthesia; Spinal; Pre-eclampsia; Spectroscopy; Near-infrared; TRANSCRANIAL DOPPLER; PERFUSION; PRESSURE;
D O I
10.1007/s10877-018-00237-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
It has been suggested that cerebral oximetry can detect acute and chronic changes in cerebral oxygen saturation due to pregnancy related complications. Furthermore, regional cerebral oxygenation saturation (rcSO(2)) decreases were obtained during spinal anesthesia for cesarean section. The aim of this prospective observational study is to compare the effects of spinal anesthesia on rcSO(2) in preeclamptic and normotensive pregnant women. Preeclamptic (Group P, n = 24) and normotensive (Group N, n = 25) women with gestational week 32 and above, and scheduled for cesarean section under spinal anesthesia were included in this study. In addition to routine monitoring, rcSO(2) values obtained with right and left frontal cerebral sensors (rcSO(2)right and rcSO(2)left) were recorded before (baseline) spinal injection and during the surgery. The baseline rcSO(2) values were similar in both groups. In Group P, rcSO(2)left values were higher than Group N only 3 and 5 min after spinal injection. In Group N, rcSO(2) values decreased from baseline 1, 3, 5, and 10 min after spinal injection. In Group P, rcSO(2) values decreased from baseline 1, 3, 5, 10, 30 and 35 min after spinal injection and at the end of the operation. There was no difference between the number of declines and the patients with rScO(2) below the cerebral hypoxic threshold. There was a positive correlation between rcSO(2) and blood pressure only 5 min after spinal injection, but no correlation with peripheral oxygen saturation was detected during the operation. There is decrease in rcSO(2) values after spinal anesthesia correlating with hypotension in preeclamptic women. However, the decrease is less than that of normotensive pregnant women, especially the first 5 min after spinal injection when the blood pressure is lowest. The clinical impact of these results and the relationship between cerebral desaturation and neurological complications remain to be determined.
引用
收藏
页码:833 / 841
页数:9
相关论文
共 50 条
  • [41] Changes of cerebral regional oxygen saturation during pneumoperitoneum and Trendelenburg position under propofol anesthesia: a prospective observational study
    Matsuoka, Toru
    Ishiyama, Tadahiko
    Shintani, Noriyuki
    Kotoda, Masakazu
    Mitsui, Kazuha
    Matsukawa, Takashi
    BMC ANESTHESIOLOGY, 2019, 19
  • [42] Effect of spinal anesthesia on the QT interval in term and post-term pregnancies scheduled for elective cesarean section: a prospective study
    Karahan, Mahmut Alp
    Incebiyik, Adnan
    Buyukfirat, Evren
    Altay, Nuray
    Binici, Orhan
    Besli, Feyzullah
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2020, 33 (18) : 3147 - 3151
  • [43] Exploring the predictive value of combined ultrasound parameters for spinal anesthesia-induced hypotension in cesarean section: a prospective observational study
    Shimiao Feng
    Juan Gu
    Chao Yu
    Jin Liu
    Juan Ni
    BMC Anesthesiology, 23
  • [44] Fear of anesthesia for cesarean section among pregnant women: a multicenter cross-sectional study
    Ramzi Shawahna
    Mohammad Jaber
    Iyad Maqboul
    Hatim Hijaz
    Eman Arjan
    Maisa Karaki
    Keen Nasser
    Perioperative Medicine, 12
  • [45] Fear of anesthesia for cesarean section among pregnant women: a multicenter cross-sectional study
    Shawahna, Ramzi
    Jaber, Mohammad
    Maqboul, Iyad
    Hijaz, Hatim
    Arjan, Eman
    Karaki, Maisa
    Nasser, Keen
    PERIOPERATIVE MEDICINE, 2023, 12 (01)
  • [46] Effect of preoperative Mg sulfate infusion on serum cardiac troponin (cTn) in moderate preeclamptic undergoing elective cesarean section under spinal anesthesia
    Elzayyat, Nashwa S.
    Yacoub, Marium H.
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2014, 30 (03) : 299 - 303
  • [47] The effects of general vs spinal anesthesia on frontal cerebral oxygen saturation in geriatric patients undergoing emergency surgical fixation of the neck of femur
    Hoppenstein, D
    Zohar, E
    Ramaty, E
    Shabat, S
    Fredman, B
    JOURNAL OF CLINICAL ANESTHESIA, 2005, 17 (06) : 431 - 438
  • [48] Type, management, and associated factors of failed spinal anesthesia in cesarean section. Prospective cohort study
    Bekele, Zenebe
    Jisha, Hunduma
    ANNALS OF MEDICINE AND SURGERY, 2022, 77
  • [49] Virtual reality treatment could reduce anxiety for women undergoing cesarean section with spinal anesthesia: a randomized controlled trial
    Xu, Yang
    Shou, Yunfeng
    Li, Yilu
    Chen, Daili
    Wen, Yajie
    Huang, Xiaolei
    Li, Yuantao
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2024, 310 (03) : 1509 - 1516
  • [50] Risk factors for postpartum depression in women undergoing elective cesarean section: A prospective cohort study
    Lin, Rong
    Lu, Yan
    Luo, Wei
    Zhang, Bing
    Liu, Zhiqiang
    Xu, Zhendong
    FRONTIERS IN MEDICINE, 2022, 9