A comparison of pullout strength for pedicle screws of different designs - A study using tapped and untapped pilot holes

被引:57
作者
Pfeiffer, Ferris M.
Abernathie, Dennis L.
机构
[1] Columbia Orthopaed Grp, Columbia, MO USA
[2] Brenoak Labs LLC, Columbia, MO USA
关键词
pedicle screw; pullout strength; tapped; untapped; pilot hole; fixation; thread form;
D O I
10.1097/01.brs.0000244658.35865.59
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. The pullout strengths of various pedicle screw designs are compared using tapped and untapped pilot holes. Objective. The objective of this study is to compare the pullout strength of various pedicle screw designs. The designs are compared using tapped and untapped pilot holes. By using several different screw designs, it is possible to gain an understanding of whether there is a correlation between tapping a pilot hole and the ultimate pullout strength. Summary of Background Data. Most bone screws originally developed were intended to be installed in a pretapped pilot hole. This same technology has been carried over to the development of more modern bone screws for use in spinal fixation applications. Many pedicle screws in use today are still intended to be installed in a tapped hole. Preparing the vertebrae and tapping of a pilot hole involve additional trauma to the patient as well as increased operating time. Methods. Pedicle screws from various manufacturers are installed in tapped and untapped pilot holes and then loaded to failure. A uniform synthetic material was used to provide a consistent test of each screw design by eliminating variability seen in bone. Results. Tapping pilot holes did not increase the pullout strength of the screws tested in this study. It was observed during testing that tapping some of the holes degraded the material. This degradation led to pullout strengths that were lower than in the untapped case, and generally larger standard deviations. Conclusions. The pullout strength was not increased by tapping for the screws in this study. Screws placed in untapped holes generally had higher pullout strengths and lower standard deviations. The results of this study suggest that tapping does not increase pullout strength in bone with densities near 20 lb/ft(3), which correlates with low density cancellous or osteoporotic bone.
引用
收藏
页码:E867 / E870
页数:4
相关论文
共 19 条
[1]   IMPLANT HOLDING POWER OF THE FEMORAL-HEAD - A CADAVER STUDY OF FRACTURE SCREWS [J].
BENTERUD, JG ;
HUSBY, T ;
GRAADAHL, O ;
ALHO, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01) :47-49
[2]   SCREW FIXATION IN THE HUMAN SACRUM - AN INVITRO STUDY OF THE BIOMECHANICS OF FIXATION [J].
CARLSON, GD ;
ABITBOL, JJ ;
ANDERSON, DR ;
KRAG, MH ;
KOSTUIK, JP ;
WOO, SLY ;
GARFIN, SR .
SPINE, 1992, 17 (06) :S196-S203
[3]   Factors affecting the pullout strength of cancellous bone screws [J].
Chapman, JR ;
Harrington, RM ;
Lee, KM ;
Anderson, PA ;
Tencer, AF ;
Kowalski, D .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03) :391-398
[4]  
DeCoster T A, 1990, J Orthop Trauma, V4, P169, DOI 10.1097/00005131-199004020-00012
[5]  
FINLAY JB, 1989, CLIN ORTHOP RELAT R, P220
[6]  
GEORGE DC, 1991, SPINE, V16, P181, DOI 10.1097/00007632-199116020-00015
[7]  
Gibson L.J., 1988, Cellular Solids, P316
[8]   Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses [J].
Hsu, CC ;
Chao, CK ;
Wang, JL ;
Hou, SM ;
Tsai, YT ;
Lin, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (04) :788-794
[9]   MECHANICAL PROPERTIES OF SURGICAL BONE SCREWS AND SOME ASPECTS OF INSERTION PRACTICE [J].
HUGHES, AN ;
JORDAN, BA .
INJURY-THE BRITISH JOURNAL OF ACCIDENT SURGERY, 1972, 4 (01) :25-&
[10]  
KRAG MH, 1986, CLIN ORTHOP RELAT R, V203, P75