Diffusion-Weighted Imaging in Patients With Acute Brain Ischemia at 3 T Current Possibilities and Future Perspectives Comparing Conventional Echoplanar Diffusion-Weighted Imaging and Fast Spin Echo Diffusion-Weighted Imaging Sequences Using BLADE (PROPELLER)

被引:30
|
作者
Fries, Peter [1 ]
Runge, Val M. [2 ]
Kirchin, Miles A. [3 ]
Stemmer, Alto [4 ]
Naul, L. Gill [2 ]
Williams, Kenneth D. [2 ]
Reith, Wolfgang [5 ]
Buecker, Arno [1 ]
Schneider, Guenther [1 ]
机构
[1] Saarland Univ Hosp, Clin Diagnost & Intervent Radiol, D-66421 Homburg, Germany
[2] Texas A&M Univ, Scott & White Clin & Hosp, Dept Radiol, Temple, TX USA
[3] Bracco Imaging SpA, World Wide Med & Regulatory Affairs, Milan, Italy
[4] Siemens AG, Hlth Care Sector, D-8520 Erlangen, Germany
[5] Saarland Univ Hosp, Clin Diagnost & Intervent Neuroradiol, Homburg, Germany
关键词
diffusion-weighted imaging (DWI); brain; cerebral ischemia; 3; T; echoplanar imaging; BLADE; PROPELLER; ACUTE STROKE; MR; MOTION; NOISE;
D O I
10.1097/RLI.0b013e3181a00d09
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare diffusion-weighted imaging (DWI) based on a fast spin echo (FSE) sequence using BLADE (PROPELLER) with conventional DWI-echoplanar imaging (EPI) techniques at 3 T and to demonstrate tire influence of hardware developments on signal-to-noise ratio (SNR) with these techniques using 12- and 32-channel head coils. Materials and Methods: Fourteen patients with brain ischemia were evaluated with DWI using EPI and FSE BLADE sequences, with a 12-channel head coil, in the axial plane and 1 additional plane (either sagittal or coronal). SNR and CNR were calculated from region-of-interest measurements. Scans were evaluated in a blinded fashion by 2 experienced neuroradiologists. SIR of both DWI techniques was evaluated in 12 healthy volunteers using different parallel imaging (PI) factors (for the EPI sequence) and both the 12- and 32-channel coils. Results: DWI-BLADE sequences acquired with tire 12-channel coil revealed a significant reduction in SNR (mean SD) of ischemic lesions (SNR(lesion) [5.0 +/- 2.5]), normal brain (SNR(brain) [3.0 +/- 1.9]), and subsequently in CNR (3.0 +/- 1.8) as compared with the DWI-EPI sequence (SNR(brain) [9.3 +/- 5.2], SNR(brain) [7.7 +/- 3.5], CNR [6.1 +/- 2.8], P < 0.001). Despite this reduction in SNR and CNR, the blinded read revealed a marked preference for the DWI-BLADE sequence, or equality between the sequences, in the majority of patients because lesion detection was degraded by susceptibility artifacts on axial DWI-EPI scans in 14% to 43%, of cases (but in no instance with the DWI-BLADE sequence). In particular, preference for the DWI-BLADE sequence or equality between the 2 techniques for lesion detection in the brain-stein and cerebellum was observed. On some DWI-BLADE scans, in the additional plane, radial-like artifacts degraded lesion detection. In volunteers, SNR was significantly improved using the 32-channel coil, irrespective of scan technique. Comparing DWI-EPI acquired with the 12-channel coil (iPAT = 2) to DWI-BLADE acquired with the 32-channel coil, comparable SNR values were obtained. The 32-channel coil also makes feasible, with DWI-EPI, an increase in the PI factor to 4, which allows for a further reduction of bulk susceptibility artifacts. However. still DWI-BLADE sequences performed better because of absence of bulk susceptibility artifacts at comparable SNR values. Conclusion: Despite lower SNR at comparable PI factors, DWI-BLADE sequences acquired using tire 12-channel coil arc preferable in most instances, as compared with DWI-EPI sequences, because of tire absence of susceptibility artifacts and subsequently improved depiction of ischemic lesions in the brainstem and cerebellum. With tire 32-channel coil, recently FDA approved, DWI-BLADE acquired with an iPAT = 2 provides comparable SNR without bulk susceptibility artifacts as compared with the DWI-EPI sequences acquired for clinical routine to date and has the potential to replace the standard DWI technique for special indications like DWI of the cerebellum and tire brainstem or in presence of metallic implants or hemorrhage.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [21] Diffusion-weighted imaging and diffusion tensor imaging in preoperative diagnostics
    Reith, W.
    RADIOLOGE, 2015, 55 (09): : 775 - 781
  • [22] Coronal Diffusion-Weighted Imaging Does Not Improve Detection of Posterior Fossa Infarcts Compared With Conventional Axial Diffusion-Weighted Imaging
    Mehan Jr, William A.
    Shin, Donghoon
    Buch, Karen
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (05) : 810 - 813
  • [23] How to perform diffusion-weighted imaging
    Bydder, GM
    Rutherford, MA
    Hajnal, JV
    CHILDS NERVOUS SYSTEM, 2001, 17 (4-5) : 195 - 201
  • [24] Diffusion-weighted MR Imaging of the Liver
    Taouli, Bachir
    Koh, Dow-Mu
    RADIOLOGY, 2010, 254 (01) : 47 - 66
  • [25] How to perform diffusion-weighted imaging
    G. M. Bydder
    M. A. Rutherford
    J. V. Hajnal
    Child's Nervous System, 2001, 17 : 195 - 201
  • [26] Diffusion-weighted imaging of the brain at 7 T with echo-planar and turbo spin echo sequences: preliminary results
    Sigmund, Eric E.
    Gutman, David
    MAGNETIC RESONANCE IMAGING, 2011, 29 (06) : 752 - 765
  • [27] Diffusion-Weighted Imaging of the Male Pelvis
    Koh, Dow-Mu
    Sohaib, Aslam
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2012, 50 (06) : 1127 - +
  • [28] Diffusion-weighted echo planar imaging of acute brain infarction: a preliminary report
    Yamada, H
    Ezuka, I
    Ikegami, Y
    Suda, T
    Kakinuma, K
    Kanazawa, T
    Higuchi, S
    NEUROLOGIA MEDICO-CHIRURGICA, 1999, 39 (13): : 913 - 921
  • [29] Imaging of the brain, including diffusion-weighted imaging in methylmalonic acidemia
    Michel, SJ
    Given, CA
    Robertson, WC
    PEDIATRIC RADIOLOGY, 2004, 34 (07) : 580 - 582
  • [30] Acute and chronic stroke: Navigated spin-echo diffusion-weighted MR imaging
    Marks, MP
    deCrespigny, A
    Lentz, D
    Enzmann, DR
    Albers, GW
    Moseley, ME
    RADIOLOGY, 1996, 199 (02) : 403 - 408