Use of cloud point extraction methodology for the determination of PAHs priority pollutants in water samples by high-performance liquid chromatography with fluorescence detection and wavelength programming

被引:101
作者
Ferrer, R [1 ]
Beltran, JL [1 ]
Guiteras, J [1 ]
机构
[1] UNIV BARCELONA,DEPT QUIM ANALIT,E-08028 BARCELONA,SPAIN
关键词
cloud point; PAHs; fluorimetry; high-performance liquid chromatography;
D O I
10.1016/0003-2670(96)00176-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The cloud point extraction methodology has been used to develop a new procedure for the preconcentration of polycyclic aromatic hydrocarbons in water samples (bottled and network supply). Triton X-114 was used as extractant agent. The procedure, consisting of three steps (preconcentration into the surfactant, clean-up and concentration of the eluate), allows good detection limits to be reached (from nanograms per liter to even sub-nanograms per liter in some cases). Determination was carried out by HPLC, with fluorimetric detection and wavelength programming.
引用
收藏
页码:199 / 206
页数:8
相关论文
共 22 条
  • [1] BARROSO SR, 1993, ANAL CHIM ACTA, V283, P304
  • [2] Determination of polycyclic aromatic hydrocarbons by HPLC with spectrofluorimetric detection and wavelength programming
    Beltran, JL
    Ferrer, R
    Guiteras, J
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (03) : 477 - 488
  • [3] Bjorseth A., 1983, HDB POLYCYCLIC AROMA
  • [4] DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN SURFACE-WATER BY COLUMN LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION, USING ONLINE MICELLE-MEDIATED SAMPLE PREPARATION
    BROUWER, ER
    HERMANS, ANJ
    LINGEMAN, H
    BRINKMAN, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) : 45 - 57
  • [5] COMPARISON OF VARIOUS EXTRACTION AND CLEANUP METHODS FOR THE DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN SEWAGE SLUDGE-AMENDED SOILS
    CODINA, G
    VAQUERO, MT
    COMELLAS, L
    BROTOPUIG, F
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 673 (01) : 21 - 29
  • [6] CLOUD POINT METHODOLOGY - A NEW APPROACH FOR PRECONCENTRATION AND SEPARATION IN HYDRODYNAMIC SYSTEMS OF ANALYSIS
    CORDERO, BM
    PAVON, JLP
    PINTO, CG
    LAESPADA, EF
    [J]. TALANTA, 1993, 40 (11) : 1703 - 1710
  • [7] EASTWOOD D, 1994, ANALUSIS, V22, P305
  • [8] DETERMINATION OF SOME SELECTED POLYCYCLIC AROMATIC-HYDROCARBONS IN ENVIRONMENTAL-SAMPLES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    GARCIA, AL
    GONZALEZ, EB
    ALONSO, JIG
    SANZMEDEL, A
    [J]. CHROMATOGRAPHIA, 1992, 33 (5-6) : 225 - 230
  • [9] APPLICATION OF FOURIER TRANSFORMATION IN HIGH-RESOLUTION GAS-CHROMATOGRAPHIC TRACE ANALYSIS
    HEVESI, T
    KRUPCIK, J
    BENICKA, E
    REPKA, D
    GARAJ, J
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1990, 9 (04) : 132 - 135
  • [10] A CRITICAL-REVIEW OF SURFACTANT-MEDIATED PHASE SEPARATIONS (CLOUD-POINT EXTRACTIONS) - THEORY AND APPLICATIONS
    HINZE, WL
    PRAMAURO, E
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1993, 24 (02) : 133 - 177