LC-MS/MS method for the determination of clodronate in human plasma

被引:12
作者
Hasan, Mahmoud [1 ,2 ]
Schumacher, Gitta [1 ]
Seekamp, Anne [1 ]
Taedken, Tobias [1 ]
Siegmund, Werner [1 ]
Oswald, Stefan [1 ]
机构
[1] Univ Med, Ctr Drug Absorpt & Transport, Dept Clin Pharmacol, Greifswald, Germany
[2] Future Univ, Dept Pharmaceut Chem, Cairo, Egypt
关键词
Clodronate; Etidronate; LC-MS/MS; Plasma; Quantification; IONIZATION MASS-SPECTROMETRY; DISODIUM CLODRONATE; RENAL-FAILURE; BISPHOSPHONATES; PHARMACOKINETICS; CHROMATOGRAPHY; TOLERABILITY; VALIDATION; URINE;
D O I
10.1016/j.jpba.2014.08.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Clodronate belongs to the class of bisphosphonates which are used for the treatment of bone disorders. Due to its high polarity it has a low and highly variable oral bioavailability which results in low plasma concentrations and requires sensitive bioanalytical methods to characterize its pharmacokinetics in human. Here, we describe for the first time the development and validation of a LC-MS/MS assay for the quantification of clodronate in human plasma. The bisphosphonate was isolated from the biological matrix by protein precipitation using perchloric acid (10%), and derivatized with trimethylorthoacetate prior sample clean-up with liquid-liquid extraction using methyl tert-butyl ether. The chromatography was performed using an isocratic elution with ammonium acetate 5 mM (85% v/v, pH 3.8) and acetonitrile (15% v/v) as mobile phase with a flow rate of 300 mu l/min on a reversed-phase column (Supelco Ascentis (R), C18) temporized at 50 C. The mass spectrometric detection was done using the API4000 triple quadruple mass spectrometer monitoring the mass/charge transitions 301.0/145 for clodronate and 305.2/137.1 for the internal standard etidronate. The analytical range was set to 5-800 ng/ml, allowing an evaluation of the plasma concentration-time profiles of clodronate for approximately 7-8 half-life (similar to 24 h). The method was validated according to current FDA/EMA guidelines on bioanalytical method validation with respect to specificity, linearity, intra- and inter-day accuracy and precision, matrix effect, recovery as well as stability. The precision of the assay was 0.6-6.9% and 0.6-8.1% for the intra-day and inter-day variability, respectively. The intra-day and inter-day accuracy (error) was 0.6-8.8% and 2.2-4.5%. The recovery of the analyte was low (2-3%) but reproducible over the entire validation range and sufficient to monitor the target concentrations in human plasma. The drug was shown to be stable in plasma at room temperature for at least 3 h (96.0 +/- 6%) and for at least 24 h when stored in the cooled autosampler at 4 degrees C (102.4 +/- 4.5%). Clodronate can also undergo up to three freeze-thaw cycles without impaired stability. Thus, the method was shown to possess sufficient specificity, sensitivity, accuracy, precision and stability to measure plasma concentrations of clodronate. Finally, the developed method was successfully applied to study the clodronate serum levels in a pharmacokinetic study in healthy volunteers. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [21] Simple and rapid LC-MS/MS method for determination of Piribedil in human plasma
    Alshishani, Anas
    Hasan, Inas
    Ghanayem, Fatima
    Al-khasawneh, Sewar
    Abu Dayah, Alaa
    [J]. PHARMACIA, 2022, 69 (03) : 615 - 620
  • [22] Determination of fentanyl in human plasma and fentanyl and norfentanyl in human urine using LC-MS/MS
    Huynh, NH
    Tyrefors, N
    Ekman, L
    Johansson, M
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (05) : 1095 - 1100
  • [23] A simple LC-MS/MS method for determination of sitafloxacin in human urine
    Wang, Yuanyuan
    Liu, Yang
    Zhang, Hongwen
    Wang, Yongqing
    Liu, Yun
    Wang, Libin
    Ou, Ning
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 967 : 219 - 224
  • [24] Determination of Anagrelide in Human Plasma by a Validated LC-MS/MS Method
    Svinarov, D.
    Kasabova, L.
    Kostova, K.
    [J]. THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 722 - 722
  • [25] Determination of Meropenem in Rabbit Plasma by LC-MS/MS
    Lin, Guanyang
    Zhang, Haiyan
    Xue, Feng
    Li, Wenjuan
    Liu, Naihua
    Chen, Lianguo
    Wang, Xianqin
    Xu, Renai
    Ma, Jianshe
    [J]. LATIN AMERICAN JOURNAL OF PHARMACY, 2011, 30 (10): : 1895 - 1900
  • [26] Determination and validation of aprepitant in rat plasma using LC-MS/MS
    Erdogar, Nazli
    Recber, Tuba
    B Iskit, Alper
    Bilensoy, Erem
    Kir, Sedef
    Nemutlu, Emirhan
    [J]. BIOANALYSIS, 2021, 13 (05) : 363 - 372
  • [27] Quantitative determination of tiopronin in human plasma by LC-MS/MS without derivatization
    Yuan, Bo
    Zhai, Nannan
    Jiang, Xue
    Jin, Yi
    Liu, Chunling
    Li, Chibing
    Xu, Haiyan
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (07) : 839 - 843
  • [28] Development and Validation of New LC-MS/MS Method for the Determination of armodafinil in Human Plasma
    Ramesh, Devi
    Ramakrishna, Singirikonda
    Habibuddin, Mohammad
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2012, 8 (03) : 295 - 305
  • [29] Determination of pethidine in human plasma by LC-MS/MS
    Wang, Xianqin
    Xiang, Zheng
    Cai, Xiaojun
    Wu, Haiya
    Wang, Xuebao
    Li, Junwei
    Zhang, Meiling
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (07) : 833 - 837
  • [30] Determination of lercanidipine in human plasma by LC-MS/MS
    Jang, Moon-Sun
    La, Sookie
    Chang, Kyu Young
    Kang, Seung Woo
    Han, Sang Beom
    Lee, Kyung Ryul
    Lee, Hee Joo
    [J]. ANALYTICAL SCIENCE AND TECHNOLOGY, 2008, 21 (01) : 34 - 40