LC-MS/MS method for the determination of clodronate in human plasma

被引:12
作者
Hasan, Mahmoud [1 ,2 ]
Schumacher, Gitta [1 ]
Seekamp, Anne [1 ]
Taedken, Tobias [1 ]
Siegmund, Werner [1 ]
Oswald, Stefan [1 ]
机构
[1] Univ Med, Ctr Drug Absorpt & Transport, Dept Clin Pharmacol, Greifswald, Germany
[2] Future Univ, Dept Pharmaceut Chem, Cairo, Egypt
关键词
Clodronate; Etidronate; LC-MS/MS; Plasma; Quantification; IONIZATION MASS-SPECTROMETRY; DISODIUM CLODRONATE; RENAL-FAILURE; BISPHOSPHONATES; PHARMACOKINETICS; CHROMATOGRAPHY; TOLERABILITY; VALIDATION; URINE;
D O I
10.1016/j.jpba.2014.08.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Clodronate belongs to the class of bisphosphonates which are used for the treatment of bone disorders. Due to its high polarity it has a low and highly variable oral bioavailability which results in low plasma concentrations and requires sensitive bioanalytical methods to characterize its pharmacokinetics in human. Here, we describe for the first time the development and validation of a LC-MS/MS assay for the quantification of clodronate in human plasma. The bisphosphonate was isolated from the biological matrix by protein precipitation using perchloric acid (10%), and derivatized with trimethylorthoacetate prior sample clean-up with liquid-liquid extraction using methyl tert-butyl ether. The chromatography was performed using an isocratic elution with ammonium acetate 5 mM (85% v/v, pH 3.8) and acetonitrile (15% v/v) as mobile phase with a flow rate of 300 mu l/min on a reversed-phase column (Supelco Ascentis (R), C18) temporized at 50 C. The mass spectrometric detection was done using the API4000 triple quadruple mass spectrometer monitoring the mass/charge transitions 301.0/145 for clodronate and 305.2/137.1 for the internal standard etidronate. The analytical range was set to 5-800 ng/ml, allowing an evaluation of the plasma concentration-time profiles of clodronate for approximately 7-8 half-life (similar to 24 h). The method was validated according to current FDA/EMA guidelines on bioanalytical method validation with respect to specificity, linearity, intra- and inter-day accuracy and precision, matrix effect, recovery as well as stability. The precision of the assay was 0.6-6.9% and 0.6-8.1% for the intra-day and inter-day variability, respectively. The intra-day and inter-day accuracy (error) was 0.6-8.8% and 2.2-4.5%. The recovery of the analyte was low (2-3%) but reproducible over the entire validation range and sufficient to monitor the target concentrations in human plasma. The drug was shown to be stable in plasma at room temperature for at least 3 h (96.0 +/- 6%) and for at least 24 h when stored in the cooled autosampler at 4 degrees C (102.4 +/- 4.5%). Clodronate can also undergo up to three freeze-thaw cycles without impaired stability. Thus, the method was shown to possess sufficient specificity, sensitivity, accuracy, precision and stability to measure plasma concentrations of clodronate. Finally, the developed method was successfully applied to study the clodronate serum levels in a pharmacokinetic study in healthy volunteers. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [11] PROTEIN PRECIPITATION METHOD FOR DETERMINATION OF OXCARBAZEPINE AND ITS 10-MONOHYDROXY DERIVATIVE IN HUMAN PLASMA BY LC-MS/MS
    Margaryan, T. S.
    Zakaryan, H. A.
    Armoudjian, Y. G.
    Gevorgyan, A. M.
    Aleksanyan, A. A.
    Sargsyan, M. S.
    Harutyunyan, A. S.
    Alaverdyan, H. R.
    Mikayelyan, A., V
    [J]. NEW ARMENIAN MEDICAL JOURNAL, 2019, 13 (03): : 57 - 64
  • [12] Development of a LC-MS/MS Method for the Determination of Dasatinib in Rat Plasma
    Cao, Shan-feng
    Wang, Xiao-min
    Zheng, Liu-chuang
    Sun, Ming
    Wang, Ying-fei
    Fan, Rui-tai
    [J]. LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (03): : 542 - 546
  • [13] Uncertainty evaluation for the determination of repaglinide in human plasma by LC-MS/MS
    Li, Jian-kang
    Li, Yan
    Chen, Minchun
    Yang, Jing
    Song, Ying
    Wang, Chao
    Jia, Yan-yan
    Wen, Ai-dong
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 2013, 18 (01) : 61 - 70
  • [14] Simultaneous determination of fludarabine and clofarabine in human plasma by LC-MS/MS
    Huang, Liusheng
    Lizak, Patricia
    Dvorak, Christopher C.
    Aweeka, Francesca
    Long-Boyle, Janel
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 960 : 194 - 199
  • [15] Determination of efonidipine in human plasma by LC-MS/MS for pharmacokinetic applications
    Liu, Man
    Zhao, Hongna
    Tong, Yang
    Zhang, Dan
    Wang, Xiaolin
    Zhang, Lina
    Han, Jing
    Liu, Huichen
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 103 : 1 - 6
  • [16] An LC-MS/MS method for the determination of ofloxacin in 20 μl human plasma
    Meredith, Sandra A.
    Smith, Peter J.
    Norman, Jennifer
    Wiesner, Lubbe
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 58 : 177 - 181
  • [17] LC-MS/MS Method Development and Validation for the Determination of Nifedipine in Human Plasma
    Logoyda, Liliya S.
    [J]. BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (05): : 6220 - 6227
  • [18] Rapid and sensitive LC-MS/MS method for determination of felbamate in mouse plasma and tissues and human plasma
    Hansen, Ryan J.
    Samber, Bradley J.
    Gustafson, Daniel L.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (32): : 3432 - 3436
  • [19] Validation of LC-MS/MS method for determination of ertapenem in human plasma and urine
    Kim, Yun-Jeong
    Han, Song-Hee
    Jeon, Ji-Young
    Hwang, Min-Ho
    Im, Yong-Jin
    Chae, Soo-Wan
    Kim, Min-Gul
    [J]. ANALYTICAL SCIENCE AND TECHNOLOGY, 2012, 25 (01) : 19 - 24
  • [20] Protein Precipitation Method for Determination of Zileuton in Human Plasma by LC-MS/MS
    Armoudjian, Yeghig
    Mikayelyan, Astghik
    Zakaryan, Hasmik
    Aleksanyan, Armine
    Alaverdyan, Harutyun
    [J]. JOURNAL OF PHARMACEUTICAL INNOVATION, 2020, 15 (04) : 581 - 590