The impact of body position on intra-abdominal pressure measurement: A multicenter analysis

被引:96
|
作者
Cheatham, Michael L. [1 ]
De Waele, Jan J. [2 ]
De Laet, Inneke [3 ]
De Keulenaer, Bart [4 ]
Widder, Sandy [5 ]
Kirkpatrick, Andrew W. [6 ,7 ]
Cresswell, Adrian B. [8 ,9 ]
Malbrain, Manu [10 ]
Bodnar, Zsolt [11 ]
Mejia-Mantilla, Jorge H. [12 ]
Reis, Richard [13 ]
Parr, Michael [14 ]
Schulze, Robert [15 ]
Puig, Sonia [16 ]
机构
[1] Orlando Reg Med Ctr Inc, Dept Surg Educ, Orlando, FL USA
[2] Ghent Univ Hosp, Surg Intens Care Unit, B-9000 Ghent, Belgium
[3] Ziekenhuis Netwerk Antwerpen, Intens Care Unit, Antwerp, Belgium
[4] Fremantle Hosp, Intens Care Unit, Fremantle, WA, Australia
[5] Univ Calgary, Dept Surg, Calgary, AB, Canada
[6] Foothills Med Ctr, Dept Crit Care Med, Calgary, AB, Canada
[7] Foothills Med Ctr, Dept Surg, Calgary, AB, Canada
[8] Kings Coll Hosp London, Liver Transplant Surg Serv, London, England
[9] Kings Coll Hosp London, Liver ITU Inst Liver Studies, London, England
[10] Ziekenhuis Netwerk Antwerpen, Intens Care Unit, Antwerp, Belgium
[11] Kenezy Teaching Hosp, Dept Surg, Debrecen, Hungary
[12] Univ Valle, Cali, Colombia
[13] Bratislava Univ, Dept Surg, Bratislava, Slovakia
[14] Liverpool Hosp, Intens Care Unit, Sydney, NSW, Australia
[15] SUNY Downstate Kings Cty Hosp, Dept Surg, Brooklyn, NY USA
[16] Hosp Mar, Barcelona, Spain
关键词
intra-abdominal pressure; intra-abdominal hypertension; abdominal compartment syndrome; intravesicular pressure; intensive care; monitoring; ABDOMINAL COMPARTMENT SYNDROME; INTERNATIONAL-CONFERENCE; CLINICAL EXAMINATION; HYPERTENSION; EXPERTS;
D O I
10.1097/CCM.0b013e3181a021fa
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Elevated intra-abdominal pressure (IAP) is a frequent cause of morbidity and mortality among the critically ill. IAP is most commonly measured using the intravesicular or "bladder" technique. The impact of changes in body position on the accuracy of IAP measurements, such as head of bed elevation to reduce the risk of ventilator-associated pneumonia, remains unclear. Design: Prospective, cohort study. Setting: Twelve international intensive care units. Patients: One hundred thirty-two critically ill medical and surgical patients at risk for intra-abdominal hypertension and abdominal compartment syndrome. Interventions: Triplicate intravesicular pressure measurements were performed at least 4 hours apart with the patient in the supine, 15 degrees, and 30 degrees head of bed elevated positions. The zero reference point was the mid-axillary line at the iliac crest. Measurements and Main Results. Mean IAP values at each head of bed position were significantly different (p < 0.0001). The bias between IAP(supine) and IAP(15)degrees was 1.5 mm Hg (1.3-1.7). The bias between IAP(supine) and IAP(30)degrees was 3.7 mm Hg (3.4-4.0). Conclusions: Head of bed elevation results in clinically significant increases in measured IAP. Consistent body positioning from one IAP measurement to the next is necessary to allow consistent trending of IAP for accurate clinical decision making. Studies that involve IAP measurements should describe the patient's body position so that these values may be properly interpreted. (Grit Care Med 2009; 37:2187-2190)
引用
收藏
页码:2187 / 2190
页数:4
相关论文
共 50 条
  • [41] Noninvasive intra-abdominal pressure measurement
    Braun, Georg
    Schaefer, Kristina
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2022, 117 (08) : 658 - 666
  • [42] What is the Relationship among Patients' Position and Intra-abdominal Pressure and Mean Arterial Pressure?
    Moghaddam, Yusef Haghighi
    Hosseinnejhad, Elnaz
    Hasanloei, Mohammad Amin Valizade
    Rasouli, Javad
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2019, 29 (06)
  • [43] Effect of increased intra-abdominal pressure and decompressive laparotomy on aerated lung volume distribution
    Zhou, Jian-cang
    Xu, Qiu-ping
    Pan, Kong-han
    Mao, Chen
    Jin, Chong-wu
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2010, 11 (05): : 378 - 385
  • [44] Influence of semi-recumbent position on intra-abdominal pressure as measured by bladder pressure
    Vasquez, Donald G.
    Berg-Copas, Gina M.
    Wetta-Hall, Ruth
    JOURNAL OF SURGICAL RESEARCH, 2007, 139 (02) : 280 - 285
  • [45] Role of intra-abdominal pressure measurement in patients with acute abdomen requiring exploratory laparotomy
    Pathania, Sumit
    Gupta, Arun Kumar
    Gupta, Nikhil
    Agrawal, Himanshu
    Durga, C. K.
    POLISH JOURNAL OF SURGERY, 2022, 94 (05) : 40 - 45
  • [46] The Increase of Intra-Abdominal Pressure Can Affect Intraocular Pressure
    Ece, Ilhan
    Vatansev, Celalettin
    Kucukkartallar, Tevfik
    Tekin, Ahmet
    Kartal, Adil
    Okka, Andmehmet
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [47] Direct measurement of intra-abdominal pressure with a solid microtranducer
    Pracca F.F.
    Biestro A.A.
    Moraes L.
    Puppo C.B.
    Calvo S.M.
    Gorrasi J.
    Cancela M.
    Journal of Clinical Monitoring and Computing, 2007, 21 (3) : 167 - 170
  • [48] INTRAPERITONEAL PRESSURE AND INTRA-ABDOMINAL PRESSURE: ARE THEY THE SAME?
    Al-Hwiesh, Abdullah
    Al-Mueilo, Sameer
    Saeed, Ibrahiem
    Al-Muhanna, Fahd A.
    PERITONEAL DIALYSIS INTERNATIONAL, 2011, 31 (03): : 315 - 319
  • [49] Non-invasive measurement of intra-abdominal pressure: a preliminary study
    van Ramshorst, G. H.
    Lange, J. F.
    Goossens, R. H. M.
    Agudelo, N. L.
    Kleinrensink, G. J.
    Verwaal, M.
    Flipsen, S. F. J.
    Hop, W. C. J.
    Wauben, L. S. G. L.
    Jeekel, J.
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (08) : N41 - N47
  • [50] Semicontinuous intra-abdominal pressure measurement using an intragastric Compliance catheter
    De Waele, Jan J.
    Berrevoet, F.
    Reyntjens, K.
    Pletinckx, P.
    De laet, I.
    Hoste, E.
    INTENSIVE CARE MEDICINE, 2007, 33 (07) : 1297 - 1300