Atraumatic Delayed Orbital Hematoma Sixteen Years After Orbital Floor Fracture Repair With Porous Polyethylene Implant

被引:7
|
作者
Slentz, Dane Harper [1 ]
Rajjoub, Lamise [2 ]
Domanski, Mark [3 ]
机构
[1] Univ Michigan, WK Kellogg Eye Ctr, Dept Ophthalmol & Visual Sci, Ann Arbor, MI 48109 USA
[2] George Washington Univ, Sch Med & Hlth Sci, Dept Ophthalmol, Washington, DC 20052 USA
[3] Inova Fairfax Hosp, Div Plast Surg, Fairfax, VA USA
关键词
Atraumatic delayed orbital hematoma; orbital floor fracture; porous polyethylene implant;
D O I
10.1097/SCS.0000000000005139
中图分类号
R61 [外科手术学];
学科分类号
摘要
Porous alloplastic materials such as titanium mesh and porous polyethylene allow for the ingrowth of fibrovascular tissues into the implant; stabilizing the implant and reducing the risk of extrusion and extrusion-related complications (such as hematoma formation). The literature contains 2 specific reports of delayed atraumatic orbital hematomas occurring 8 months and 3 years after orbital floor reconstruction with porous polyethylene implants. In this study, an atraumatic orbital hematoma occurring 16 years after orbital floor reconstruction with a porous polyethylene implant was presented. The hematoma was evacuated and the implant was removed without replacement of a secondary implant. The remaining fibrovascular tissue on the underside of the implant provided enough support of the orbital soft tissues to achieve excellent anatomic and physiologic outcomes.
引用
收藏
页码:539 / 540
页数:2
相关论文
共 24 条
  • [1] Delayed-Onset Orbital Abscess After Orbital Blowout Fracture Repair Using Porous Polyethylene Implant
    Han, Kwang Eon
    Ahn, Jung Hyo
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (06) : e588 - e590
  • [2] Porous Polyethylene Implant Associated With Delayed Orbital Complications and Osteomyelitis After Orbital Reconstruction
    Suh, Su Youn
    Yeom, Jeong A.
    Ahn, Jung Hyo
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (07) : 1910 - 1911
  • [3] INFERIOR RECTUS MUSCLE ENTRAPPED BY TEFLON IMPLANT AFTER ORBITAL FLOOR FRACTURE REPAIR
    MAURIELLO, JA
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 6 (03): : 218 - 220
  • [4] The Role of Postoperative Imaging after Orbital Floor Fracture Repair
    Carpenter, David
    Shammas, Ronnie
    Honeybrook, Adam
    Brown, C. Scott
    Chapurin, Nikita
    Woodard, Charles R.
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2018, 11 (02) : 96 - 101
  • [5] Porous Polyethylene Implants in Orbital Floor Reconstruction
    I-Chan Lin
    Shu-Lang Liao
    Luke L-K Lin
    Japanese Journal of Ophthalmology, 2006, 50 : 187 - 188
  • [6] Porous polyethylene implants in orbital floor reconstruction
    Lin, IC
    Liao, SL
    Lin, LLK
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2006, 50 (02) : 187 - 188
  • [7] Feasibility Study for Transnasal Endoscopic Repair of Orbital Floor Fracture With Alloplastic Implant
    Engle, Robert D.
    Chaskes, Mark
    Wladis, Edward
    Pinheiro-Neto, Carlos D.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2016, 125 (12): : 970 - 975
  • [8] Quantitative assessment of increase in orbital volume after orbital floor fracture reconstruction using a bioabsorbable implant
    Hyun Young Park
    Tae Hyung Kim
    Jin Sook Yoon
    JaeSang Ko
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 3027 - 3036
  • [9] Quantitative assessment of increase in orbital volume after orbital floor fracture reconstruction using a bioabsorbable implant
    Park, Hyun Young
    Kim, Tae Hyung
    Yoon, Jin Sook
    Ko, JaeSang
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (09) : 3027 - 3036
  • [10] Repair of blowout orbital floor fracture by periosteal suturing
    Noda, Mika
    Noda, Kousuke
    Ideta, Shinji
    Nakamura, Yasuhisa
    Ishida, Susumu
    Inoue, Makoto
    Tsubota, Kazuo
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (04): : 364 - 369