Using labelled internal standards to improve needle trap micro-extraction technique prior to gas chromatography/mass spectrometry

被引:23
作者
Biagini, Denise [1 ]
Lomonaco, Tommaso [1 ]
Ghimenti, Silvia [1 ]
Onor, Massimo [2 ]
Bellagambi, Francesca G. [1 ]
Salvo, Pietro [3 ]
Di Francesco, Fabio [1 ]
Fuoco, Roger [1 ]
机构
[1] Univ Pisa, Dept Chem & Ind Chem, Via Giuseppe Moruzzi 13, Pisa, Italy
[2] CNR, Inst Chem Organometall Cpds, Via Giuseppe Moruzzi 3, Pisa, Italy
[3] CNR, Inst Clin Physiol, Via Giuseppe Moruzzi 3, Pisa, Italy
关键词
Volatile organic compounds; Breath analysis; Needle trap micro-extraction; Labelled internal standards; GC-MS; VOLATILE ORGANIC-COMPOUNDS; BREATH ANALYSIS; MASS-SPECTROMETRY; SAMPLING METHODS; EXHALED BREATH; AIR; DIAGNOSIS; EXPOSURE; DEVICE; BLOOD;
D O I
10.1016/j.talanta.2019.03.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
When working with humid gaseous samples, the amount of water vapour collected in a needle trap along with volatile analytes may vary from sample to sample and decrease during the storage. This has a major impact on desorption efficiency and recovery. We propose the addition of a labelled internal standards to nullify the effect of variable humidity on the analytical performance of needle trap micro-extraction combined with gas chromatography mass spectrometry. Triple-bed (Divinylbenzene/Carbopack X/Carboxen 1000) and single-bed (Tenax GR) needles were tested with standard gaseous mixtures prepared at different relative humidity levels (85%, 50% and 10%). The standard mixtures contained twenty-five analytes representative of breath and ambient air constituents, including hydrocarbons, ketones, aldehydes, aromatics, and sulphurs, in the concentration range 0.1-700 ppbv. The two needles showed different behaviours, as recovery was independent of humidity for single-beds, whereas a low recovery (10-20%) was observed when triple-beds trapped very volatile compounds at low humidity (e.g. pentane and ethanol, 10% relative humidity. Triple-beds showed an almost quantitative recovery (> 90%) of all the analytes at 50% and 85% relative humidity. This big difference was probably due to the reduced action of water vapour pressure during the desorption step. The addition of D-6-acetone and D-8-toluene to the sorbent material before gas sampling and the normalization of raw data nullified this effect, thereby lowering the variations of analyte recovery at different humidity levels down to 20%. Internal standards were also exploited to limit within 10-20% alterations in peak areas of very volatile compounds during needle storage at room temperature. This variation may results from a loss of water vapour either retained from the sorbent material and/or condensed on triple-bed needle walls. After normalization, the inter- and infra-day precision were halved to 5% and 10% in the case of single-beds, respectively, and to 15% and 20% with three beds. The addition of an internal standard to the sorbent helps to keep the overall analytical procedure under control and improves the reliability of needle trap micro-extraction for the analysis of volatile organic compounds at ultra-trace levels.
引用
收藏
页码:145 / 155
页数:11
相关论文
共 50 条
  • [21] Direct analysis of free-base nicotine in tobacco leaf by headspace solid-phase micro-extraction combined with gas chromatography/mass spectrometry
    Tang, Li
    Yang, Haowei
    He, Liang
    Wang, Meng
    Zhu, Baokun
    Liao, Tougen
    ACCREDITATION AND QUALITY ASSURANCE, 2019, 24 (05) : 341 - 349
  • [22] A method to detect diphenylamine contamination of apple fruit and storages using headspace solid phase micro-extraction and gas chromatography/mass spectroscopy
    Song, Jun
    Forney, Charles F.
    Jordan, Michael A.
    FOOD CHEMISTRY, 2014, 160 : 255 - 259
  • [23] Efficient sampling and determination of airborne N-nitrosamines by needle trap device coupled with gas chromatography-mass spectrometry
    Chen, Xiao
    Yang, Shenghong
    Hu, Qingkun
    Cheng, Hu
    Chen, Zhuo
    Ouyang, Gangfeng
    MICROCHEMICAL JOURNAL, 2018, 139 : 480 - 486
  • [24] Supercritical fluid extraction combined on-line with cold-trap gas chromatography mass spectrometry
    Fuoco, R
    Ceccarini, A
    Onor, M
    Lottici, S
    ANALYTICA CHIMICA ACTA, 1997, 346 (01) : 81 - 86
  • [25] Determination of Multiresidue Pesticides in Green Tea by Using a Modified QuEChERS Extraction and Ion-Trap Gas Chromatography/Mass Spectrometry
    Steiniger, David
    Lu, Guiping
    Butler, Jessie
    Phillips, Eric
    Fintschenko, Yolanda
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (04) : 1169 - 1179
  • [26] Research on determination of BTEX in human whole blood using purge and trap-gas chromatography-mass spectrometry combined with isotope internal standard
    Zhao, Liangyuan
    Qin, Xiaojiang
    Hou, Xiaomin
    Li, Yanhua
    Zhang, Kun
    Gong, Wei
    Nie, Jisheng
    Wang, Tong
    MICROCHEMICAL JOURNAL, 2019, 145 : 308 - 312
  • [27] CHARACTERIZATION OF OIL BY MICRO-SOLID-PHASE EXTRACTION AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    Yang, Baijuan
    Yu, Zhigang
    Yao, Peng
    Jiang, Fenghua
    Chen, Junhui
    ANALYTICAL LETTERS, 2015, 48 (15) : 2493 - 2506
  • [28] Gas chromatography mass spectrometry determination of acaricides from honey after a new fast ultrasonic-based solid phase micro-extraction sample treatment
    Rial-Otero, R.
    Gaspar, E. M.
    Moura, I.
    Capelo, J. L.
    TALANTA, 2007, 71 (05) : 1906 - 1914
  • [29] Determination of volatile organic compounds in pen inks by a dynamic headspace needle trap device combined with gas chromatography-mass spectrometry
    Zang, Xiaohuan
    Liang, Weiqian
    Chang, Qingyun
    Wu, Tong
    Wang, Chun
    Wang, Zhi
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1513 : 27 - 34
  • [30] Measurement of trihalomethanes in potable and recreational waters using solid phase micro extraction with gas chromatography-mass spectrometry
    Stack, MA
    Fitzgerald, G
    O'Connell, S
    James, KJ