Image Retake Analysis in Digital Radiography Using DICOM Header Information

被引:36
作者
Prieto, C. [1 ]
Vano, E. [1 ,2 ]
Ten, J. I. [3 ]
Fernandez, J. M. [1 ]
Iniguez, A. I. [3 ]
Arevalo, N. [3 ]
Litcheva, A. [3 ]
Crespo, E. [3 ]
Floriano, A. [1 ]
Martinez, D. [1 ]
机构
[1] San Carlos Univ Hosp, Med Phys Serv, Madrid 20840, Spain
[2] Univ Complutense, Sch Med, Dept Radiol, E-28040 Madrid, Spain
[3] San Carlos Univ Hosp, Serv Radiol, Madrid 20840, Spain
关键词
Diagnostic image quality; Digital Imaging and Communications in Medicine (DICOM); image analysis; COMPARATIVE REJECT ANALYSIS; CONVENTIONAL FILM-SCREEN; QUALITY;
D O I
10.1007/s10278-008-9135-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A methodology to automatically detect potential retakes in digital imaging, using the Digital Imaging and Communications in Medicine (DICOM) header information, is presented. In our hospital, neither the computed radiography workstations nor the picture archiving and communication system itself are designed to support reject analysis. A system called QCOnline, initially developed to help in the management of images and patient doses in a digital radiology department, has been used to identify those images with the same patient identification number, same modality, description, projection, date, cassette orientation, and image comments. The pilot experience lead to 6.6% and 1.9% repetition rates for abdomen and chest images. A thorough analysis has shown that the real repetitions were 3.3% and 0.9% for abdomen and chest images being the main cause of the discrepancy being the wrong image identification. The presented methodology to automatically detect potential retakes in digital imaging using DICOM header information is feasible and allows to detect deficiencies in the department performance like wrong identifications, positioning errors, wrong radiographic technique, bad image processing, equipment malfunctions, artefacts, etc. In addition, retake images automatically collected can be used for continuous training of the staff.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 16 条
[1]   REJECT ANALYSIS - A PILOT PROGRAM FOR IMAGE QUALITY MANAGEMENT [J].
ARVANITIS, TN ;
PARIZEL, PM ;
DEGRYSE, HR ;
DESCHEPPER, AMA .
EUROPEAN JOURNAL OF RADIOLOGY, 1991, 12 (03) :171-176
[2]  
BOONE JM, 2002, 74 AAPM
[3]  
*BRIT I RAD, 1998, QUAL ASS DIAGN XRAY
[4]  
Dunn M.A., 1998, Radiography, V4, P29, DOI DOI 10.1016/S1078-8174(98)80027-8
[5]   The DIMOND project and its impact on radiation protection [J].
Faulkner, K .
RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) :3-6
[6]   QUALITY-CONTROL OF STORAGE PHOSPHOR DIGITAL RADIOGRAPHY SYSTEMS [J].
FREEDMAN, M ;
STELLER, D ;
JAFROUDI, H ;
MUN, SK .
JOURNAL OF DIGITAL IMAGING, 1995, 8 (02) :67-74
[7]  
GADEHOLT G, 1989, EUR J RADIOL, V9, P137
[8]  
Hardy M., 2001, RADIOGRAPHY, V7, P159
[9]  
Honea Rosemary, 2002, J Digit Imaging, V15 Suppl 1, P41, DOI 10.1007/s10278-002-5028-7
[10]  
International Commission on Radiological Protection, 2004, Ann ICRP, V34, P1