Access to magnetic resonance imaging of patients withmagnetic resonance-conditional pacemaker and implantable cardioverter-defibrillator systems: results from the Really ProMRI study

被引:27
作者
Celentano, Eduardo [1 ,2 ]
Caccavo, Vincenzo [3 ]
Santamaria, Matteo [4 ]
Baiocchi, Claudia [5 ]
Melissano, Donato [6 ]
Pisano, Ennio [7 ]
Gallo, Paolo [8 ]
Polcino, Antonio [9 ]
Arena, Giuseppe [10 ]
Patane, Santina [11 ]
Senatore, Gaetano [12 ]
Licciardello, Giovanni [13 ]
Padeletti, Luigi [14 ]
Vado, Antonello [15 ]
Giorgi, Davide [16 ]
Pecora, Domenico [17 ]
Stella, Prospero [18 ]
Anaclerio, Matteo [19 ]
Guastaferro, Ciro [20 ]
Giovannini, Tiziana [21 ]
Giacopelli, Daniele [22 ]
Gargaro, Alessio [22 ]
Maglia, Giampiero [23 ]
机构
[1] Fdn Cardimed, Pomigliano Darco, Italy
[2] CDC IOS MF Grp, Pomigliano Darco, Italy
[3] Osped EE Miulli Acquaviva Fonti, Bari, Italy
[4] Fdn G Paolo II, Campobasso, Italy
[5] Policlin Le Scotte, Siena, Italy
[6] POF Ferrari, Lecce, Italy
[7] PO Vito Fazzi, Lecce, Italy
[8] CDC Villa Fiori, Naples, Italy
[9] AOG Rummo, Benevento, Italy
[10] Nuovo Osped Apuano Marina, Massa, Italy
[11] PO Papardo, AOOR Papardo Piemonte, PO Papardo, Messina, Italy
[12] Osped Cirie, Turin, Italy
[13] PO Muscatello, Augusta, Siracusa, Italy
[14] AOU Careggi, Florence, Italy
[15] Osped S Croce & Carlo, Cuneo, Italy
[16] Osped Campo Marte, Lucca, Italy
[17] Fdn Poliambulanza, Brescia, Italy
[18] Osped Santa Maria Misericordia, Naples, Italy
[19] Policlin Consorziale, Bari, Italy
[20] OORR Area Stabiese, Naples, Italy
[21] Nuovo Osped Prato, Prato, Italy
[22] BIOTRONIK Italia SpA, Milan, Italy
[23] AO Pugliese Ciaccio, Catanzaro, Italy
来源
EUROPACE | 2018年 / 20卷 / 06期
关键词
Magnetic resonance imaging; Cardiac implantable electronic devices; Pacemaker; Implantable cardioverter-defibrillator; MR-conditional devices; SCANNING CONDITIONS; ELECTRONIC DEVICES; CLINICAL SAFETY; THORACIC SPINE; MRI; RISKS;
D O I
10.1093/europace/eux118
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The Really ProMRI study evaluates magnetic resonance imaging (MRI) access for patients with cardiac implantable electronic devices (CIEDs) as well as the performance of magnetic resonance (MR)-conditional leads when undergoing MRI. Methods and results Patients either with an MR-conditional pacemaker or implantable defibrillator (ICD) system or with at least a component (device or one or more leads) from an MR-conditional system, were asked to fill in a questionnaire when they were referred to a MR scan. The rate of prescription, denial, or execution of MR examinations was evaluated in a 1-year follow-up visit. In total, 555 patients [median age (interquartile range) 72.2 (62.2-78.6); 72% male] were enrolled, 49% (270) with a pacemaker, 51% (285) with an ICD system. Five-hundred and ten patients completed the follow-up period. A total of 37 MRI referrals were reported in 35 patients, with a consequent event rate of 7.0/100 patient-years (CI, 4.9-9.7). Fourteen were denied, while 23 [66%; (CI, 48-81%)] were performed. The number of patients with MR referrals was not statistically different between pacemaker and ICD groups (21 vs. 14; P = 0.178). The rate of scans performed was higher in the pacemaker subjects (19/23 vs. 4/14, P = 0.003), while it was similar between patients with or without a complete MR-conditional system (19/30 vs. 4/7, P = 0.606). Conclusion In this study, we reported a 7.0/100 patient-year's event rate of MR prescriptions in CIED patients. Many examinations were denied, despite MR-conditional systems, especially in ICD patients. Regulatory and cultural changes are needed to allow wider access to MR imaging in CIED patients with MR-conditional systems.
引用
收藏
页码:1001 / 1009
页数:9
相关论文
共 26 条
[1]   Not All Pacemakers Are Created Equal: MRI Conditional Pacemaker and Lead Technology [J].
Ahmed, Fozia Z. ;
Morris, Gwilym M. ;
Allen, Stuart ;
Khattar, Rajdeep ;
Mamas, Mamas ;
Zaidi, Amir .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (09) :1059-1065
[2]  
[Anonymous], 2018, Magnetic resonance imaging (MRI) exams (indicator, DOI [DOI 10.1787/1D89353F-EN, 10.1787/1d89353f-en]
[3]   Clinical safety of the Iforia implantable cardioverter-defibrillator system in patients subjected to thoracic spine and cardiac 1.5-T magnetic resonance imaging scanning conditions [J].
Awad, Khaled ;
Griffin, John ;
Crawford, Thomas C. ;
Cox, S. Lane ;
Ferrick, Kevin ;
Mazur, Alexander ;
Pena, Rafael E. ;
Lloyd, Steven G. ;
Michalski, Justin ;
Johnson, Whitney ;
Bailey, William M. .
HEART RHYTHM, 2015, 12 (10) :2155-2161
[4]   Clinical safety of the ProMRI pacemaker system in patients subjected to thoracic spine and cardiac 1.5-T magnetic resonance imaging scanning conditions [J].
Bailey, William M. ;
Mazur, Alexander ;
McCotter, Craig ;
Woodard, Pamela K. ;
Rosenthal, Lawrence ;
Johnson, Whitney ;
Mela, Theofanie .
HEART RHYTHM, 2016, 13 (02) :464-471
[5]   2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy [J].
Brignole, Michele ;
Auricchio, Angelo ;
Baron-Esquivias, Gonzalo ;
Bordachar, Pierre ;
Boriani, Giuseppe ;
Breithardt, Ole-A ;
Cleland, John ;
Deharo, Jean-Claude ;
Delgado, Victoria ;
Elliott, Perry M. ;
Gorenek, Bulent ;
Israel, Carsten W. ;
Leclercq, Christophe ;
Linde, Cecilia ;
Mont, Llus ;
Padeletti, Luigi ;
Sutton, Richard ;
Vardas, Panos E. ;
Zamorano, Jose Luis ;
Achenbach, Stephan ;
Baumgartner, Helmut ;
Bax, Jeroen J. ;
Bueno, Hctor ;
Dean, Veronica ;
Deaton, Christi ;
Erol, Cetin ;
Fagard, Robert ;
Ferrari, Roberto ;
Hasdai, David ;
Hoes, Arno W. ;
Kirchhof, Paulus ;
Knuuti, Juhani ;
Kolh, Philippe ;
Lancellotti, Patrizio ;
Linhart, Ales ;
Nihoyannopoulos, Petros ;
Piepoli, Massimo F. ;
Ponikowski, Piotr ;
Sirnes, Per Anton ;
Tamargo, Juan Luis ;
Tendera, Michal ;
Torbicki, Adam ;
Wijns, William ;
Windecker, Stephan ;
Kirchhof, Paulus ;
Blomstrom-Lundqvist, Carina ;
Badano, Luigi P. ;
Aliyev, Farid ;
Bnsch, Dietmar ;
Baumgartner, Helmut .
EUROPACE, 2013, 15 (08) :1070-1118
[6]   Determining the Risks of Magnetic Resonance Imaging at 1.5 Tesla for Patients With Pacemakers and Implantable Cardioverter Defibrillators [J].
Cohen, Jennifer D. ;
Costa, Heather S. ;
Russo, Robert J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (11) :1631-1636
[7]   Complete loss of ICD programmability after magnetic resonance imaging [J].
Fiek, M ;
Remp, T ;
Reithmann, C ;
Steinbeck, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (07) :1002-1004
[8]   Full-Body MRI in Patients With an Implantable Cardioverter-Defibrillator Primary Results of a Randomized Study [J].
Gold, Michael R. ;
Sommer, Torsten ;
Schwitter, Juerg ;
Al Fagih, Ahmed ;
Albert, Timothy ;
Merkely, Bela ;
Peterson, Michael ;
Ciuffo, Allen ;
Lee, Sung ;
Landborg, Lynn ;
Cerkvenik, Jeffrey ;
Kanal, Emanuel .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (24) :2581-2588
[9]   "Power-on resets" in cardiac implantable electronic devices during magnetic resonance imaging [J].
Higgins, John V. ;
Sheldon, Seth H. ;
Watson, Robert E., Jr. ;
Dalzell, Connie ;
Acker, Nancy ;
Cha, Yong-Mei ;
Asirvatham, Samuel J. ;
Kapa, Suraj ;
Felmlee, Joel P. ;
Friedman, Paul A. .
HEART RHYTHM, 2015, 12 (03) :540-544