Assessing sample attenuation parameters for use in low-energy efficiency transfer in gamma-ray spectrometry

被引:2
|
作者
Bruggeman, M. [1 ]
Verheyen, L. [1 ]
Vidmar, T. [1 ]
Liu, B. [2 ]
机构
[1] Studiectr Kernenergie, Boeretang 200, B-2400 Mol, Belgium
[2] Ecoles Mines Nantes, Rue Alfred Kastler 4, F-44300 Nantes, France
关键词
Gamma-ray spectrometry; Efficiency transfer; EFFTRAN; Attenuation correction; Attenuation coefficients; Gamma-ray self-attenuation; Transmission measurement; SEDIMENT SAMPLES; PB-210;
D O I
10.1016/j.apradiso.2015.11.077
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
We present a numerical fitting method for transmission data that outputs an equivalent sample composition. This output is used as input to a generalised efficiency transfer model based on the EFFTRAN software integrated in a LIMS. The procedural concept allows choosing between efficiency transfer with a predefined sample composition or with an experimentally determined composition based on a transmission measurement. The method can be used for simultaneous quantification of low-energy gamma emitters like Pb-210, Am-241, Th-234 in typical environmental samples. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:547 / 550
页数:4
相关论文
共 50 条
  • [1] Intercomparison of efficiency transfer software for gamma-ray spectrometry
    Lépy, MC
    Altzitzoglou, T
    Arnold, D
    Bronson, F
    Noy, RC
    Décombaz, M
    De Corte, F
    Edelmaier, R
    Peraza, EH
    Klemola, S
    Korun, M
    Kralik, M
    Neder, H
    Plagnard, J
    Pommé, S
    de Sanoit, J
    Sima, O
    Ugletveit, F
    Van Velzen, L
    Vidmar, T
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (04) : 493 - 503
  • [2] Crystal rounding and the efficiency transfer method in gamma-ray spectrometry
    Vidmar, Tim
    Gasparro, Joel
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (11) : 2057 - 2061
  • [3] EFFTRAN - A Monte Carlo efficiency transfer code for gamma-ray spectrometry
    Vidmar, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 550 (03) : 603 - 608
  • [4] Propagation of the uncertainties of sample position to the uncertainty of the counting efficiency in gamma-ray spectrometry
    Korun, M
    APPLIED RADIATION AND ISOTOPES, 2002, 57 (03) : 415 - 425
  • [5] Propagation of uncertainties in sample properties to the uncertainty of the counting efficiency in gamma-ray spectrometry
    Korun, M
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (05) : 685 - 691
  • [6] A low-energy set-up for gamma-ray spectrometry of NORM tailored to the needs of a secondary smelting facility
    Lutter, G.
    Schreurs, I. Vandael
    Croymans, T.
    Schroeyers, W.
    Schreurs, S.
    Hult, M.
    Marissens, G.
    Stroh, H.
    Tzika, F.
    APPLIED RADIATION AND ISOTOPES, 2017, 126 : 296 - 299
  • [7] Comparison of gamma-ray coincidence and low-background gamma-ray singles spectrometry
    Konki, J.
    Greenlees, P. T.
    Jakobsson, U.
    Jones, P.
    Julin, R.
    Juutinen, S.
    Ketelhut, S.
    Hauschild, K.
    Kontro, R.
    Leppanen, A. -P.
    Lopez-Martens, A.
    Mattila, A.
    Nieminen, P.
    Nyman, M.
    Perajarvi, K.
    Peura, P.
    Rahkila, P.
    Ruotsalainen, P.
    Saren, J.
    Scholey, C.
    Sorri, J.
    Toivonen, H.
    Turunen, J.
    Uusitalo, J.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (02) : 392 - 396
  • [8] On within sample homogeneity testing using gamma-ray spectrometry
    Suvaila, Rares
    Stancu, Elena
    Sima, Octavian
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2144 - 2148
  • [9] Use of airborne gamma-ray spectrometry for kaolin exploration
    Tourlière, B
    Perrin, J
    Le Berre, P
    Pasquet, JF
    JOURNAL OF APPLIED GEOPHYSICS, 2003, 53 (2-3) : 91 - 102
  • [10] A METHOD OF EFFICIENCY CALIBRATION FOR DISK SOURCES IN GAMMA-RAY SPECTROMETRY
    Radu, Daniela
    Stanga, Doru
    Sima, Octavian
    ROMANIAN REPORTS IN PHYSICS, 2009, 61 (02) : 203 - 213