Three-dimensional cerebral contrast-enhanced magnetic resonance venography at 3.0 Tesla - Initial results using highly accelerated parallel acquisition

被引:27
作者
Nael, Kambiz
Fenchel, Michael
Salamon, Noriko
Duckwiler, Gary R.
Laub, Gerhard
Finn, J. Paul
Villablanca, J. Pablo
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[2] Univ Tubingen, Tubingen, Germany
[3] Siemens Med Solut, Los Angeles, CA USA
关键词
3D cerebral venography; contrast-enhanced MR venography; high magnetic field; 3.0; Tesla; parallel acquisition techniques;
D O I
10.1097/01.rli.0000236992.21065.04
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objective of this study was to evaluate a high spatial resolution 3-dimensional (3D) contrast-enhanced magnetic resonance (CE-MR) venography protocol for evaluation of intracranial venous system using highly accelerated parallel imaging at 3.0 T. Materials and Methods: Ten patients (4 male, 6 female; age, 38-76 years) with suspected cerebrovascular disease were prospectively studied on a 32-channel 3.0 T MR system. After a single intravenous contrast injection, high spatial resolution 3D CE-MR angiography of the entire supraaortic arteries was performed followed immediately by 3D cerebral CE-MR venography. By using a fast 3D gradient-recalled-echo sequence with elliptic centric k-space ordering and highly accelerated parallel acquisition (acceleration factor 3 and 2 in phase and slice encoding direction, respectively), 3D cerebral CE-MR venograpby was acquired with voxel dimensions of 0.7 X 0.7 X 0.8 mm(3) in 24 seconds. Image evaluation was performed independently by 2 neuroradiologists for overall image quality, presence of noise, and artifacts. The image quality of 30 venous segments was evaluated in each subject using a I to 4 scoring scale. In 2 patients, catheter angiography was available for correlation. Statistical analysis of data was performed by using Wilcoxon rank sum test and kappa coefficient. Results: All studies were determined to be of diagnostic image quality by both observers. The majority (90%) of cerebral venous segments were evaluated to be of diagnostic image quality (median, 3; range, 3-4) by both readers and with excellent interobserver agreement (kappa = 0.86; 95% confidence interval, 0.79-0.93). One meningiorna invading the superior sagittal sinus and one superior sagittal sinus fistula were detected subsequently confirmed by conventional angiography. Conclusion: High spatial resolution 3D cerebral CE-MR venography is feasible and promising. Using a 32-channel 3.0 T system combined with multichannel array coils effectively supports highly accelerated parallel imaging, enabling subsequent acquisition of both high spatial resolution CE-MR angiography and CE-MR venography after a single contrast injection without impairing the image quality. More extensive clinical studies are warranted to establish the range of applications and confirm the accuracy of this technique.
引用
收藏
页码:763 / 768
页数:6
相关论文
共 26 条
[1]  
Ayanzen RH, 2000, AM J NEURORADIOL, V21, P74
[2]   Signal-to-noise ratio and parallel Imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla [J].
de Zwart, JA ;
Ledden, PJ ;
van Gelderen, P ;
Bodurka, J ;
Chu, RX ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :22-26
[3]  
Fain SB, 1999, MAGNET RESON MED, V42, P1106, DOI 10.1002/(SICI)1522-2594(199912)42:6<1106::AID-MRM15>3.0.CO
[4]  
2-Q
[5]   Intracranial venous system: Gadolinium-enhanced three-dimensional MR venography with auto-trigered elliptic centric-ordered sequence - Initial experience [J].
Farb, RI ;
Scott, JN ;
Willinsky, RA ;
Montanera, W ;
Wright, GA ;
terBrugge, KG .
RADIOLOGY, 2003, 226 (01) :203-209
[6]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[7]  
Huston J, 2001, RADIOLOGY, V218, P138
[8]   APPLICATION OF HIERARCHICAL KAPPA-TYPE STATISTICS IN ASSESSMENT OF MAJORITY AGREEMENT AMONG MULTIPLE OBSERVERS [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (02) :363-374
[9]  
Liang LX, 2002, AM J NEURORADIOL, V23, P1739
[10]   MR angiography of the intracranial venous system [J].
Liauw, L ;
van Buchem, MA ;
Spilt, A ;
de Bruïne, FT ;
van den Berg, R ;
Hermans, J ;
Wasser, MNJM .
RADIOLOGY, 2000, 214 (03) :678-682