Robust water-fat separation for multi-echo gradient-recalled echo sequence using convolutional neural network

被引:15
作者
Cho, JaeJin [1 ]
Park, HyunWook [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, 291 Daehak Ro, Daejeon 34141, South Korea
关键词
convolutional neural network; multi-echo gradient-recalled echo; water-fat separation; PHASE; FIELDS;
D O I
10.1002/mrm.27697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To accurately separate water and fat signals for bipolar multi-echo gradient-recalled echo sequence using a convolutional neural network (CNN). Methods: A CNN architecture was designed and trained using the relationship between multi-echo images from the bipolar multi-echo gradient-recalled echo sequence and artifact-free water-fat-separated images. The artifact-free water-fat-separated images for training the CNN were obtained from multiple signals with different TEs by using iterative decomposition of water and fat with echo asymmetry and the least-squares estimation method, in which multiple signals at different TEs were acquired using a single-echo gradient-recalled echo sequence. We also proposed a data augmentation method using a synthetic field inhomogeneity to generate multi-echo signals, including various bipolar multi-echo gradient-recalled echo artifacts so that the CNN could prevent overfitting and increase the separation accuracy. We trained the CNN using in vivo knee images and tested it using in vivo knee, head, and ankle images. Results: In vivo imaging results showed that the proposed CNN could separate water-fat images accurately. Although the proposed CNN was trained using only in vivo knee images, the proposed CNN could also separate water-fat images of different imaging regions. The proposed data augmentation method could prevent overfitting even with a limited number of training data sets and make the method robust to magnetic field inhomogeneities. Conclusion: The proposed CNN could obtain water-fat-separated images from the multi-echo images acquired from the bipolar multi-echo gradient-recalled echo sequence, which included artifacts from the bipolar gradients.
引用
收藏
页码:476 / 484
页数:9
相关论文
共 28 条
  • [1] Abadi M, 2016, ACM SIGPLAN NOTICES, V51, P1, DOI [10.1145/2951913.2976746, 10.1145/3022670.2976746]
  • [2] [Anonymous], 2014, 14091556 ARXIV
  • [3] [Anonymous], P 25 SCI M ISMRM HON
  • [4] Ba J., 2014, 14126980 ARXIV
  • [5] TEMPORAL AND SPATIAL-ANALYSIS OF FIELDS GENERATED BY EDDY CURRENTS IN SUPERCONDUCTING MAGNETS - OPTIMIZATION OF CORRECTIONS AND QUANTITATIVE CHARACTERIZATION OF MAGNET GRADIENT SYSTEMS
    BOESCH, C
    GRUETTER, R
    MARTIN, E
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (02) : 268 - 284
  • [6] Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction
    Chen, NK
    Wyrwicz, AM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (06) : 1247 - 1253
  • [7] Deep, Big, Simple Neural Nets for Handwritten Digit Recognition
    Ciresan, Dan Claudiu
    Meier, Ueli
    Gambardella, Luca Maria
    Schmidhuber, Juergen
    [J]. NEURAL COMPUTATION, 2010, 22 (12) : 3207 - 3220
  • [8] SIMPLE PROTON SPECTROSCOPIC IMAGING
    DIXON, WT
    [J]. RADIOLOGY, 1984, 153 (01) : 189 - 194
  • [9] Elimination of Nyquist ghosting caused by read-out to phase-encode gradient cross-terms in EPI
    Grieve, SM
    Blamire, AM
    Styles, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) : 337 - 343
  • [10] Addressing phase errors in fat-water imaging using a mixed magnitude/complex fitting method
    Hernando, D.
    Hines, C. D. G.
    Yu, H.
    Reeder, S. B.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) : 638 - 644