Polaroid-PET: a PET scanner with detectors fitted with Polaroid for filtering unpolarized optical photons-a Monte Carlo simulation study

被引:3
|
作者
Sanaat, Amirhossein [1 ]
Ashrafi-Belgabad, Aydin [2 ]
Zaidi, Habib [1 ,3 ,4 ,5 ]
机构
[1] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[2] Amirkabir Univ Technol, Phys & Energy Engn Dept, Tehran, Iran
[3] Univ Geneva, Geneva Univ Neuroctr, CH-1205 Geneva, Switzerland
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[5] Univ Southern Denmark, Dept Nucl Med, DK-500 Odense, Denmark
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 23期
基金
瑞士国家科学基金会;
关键词
PET; instrumentation; detectors; Polaroids; spatial resolution; RESOLUTION; ACCURACY;
D O I
10.1088/1361-6560/abaeb8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose and evaluate the performance of an improved preclinical positron emission tomography (PET) scanner design, referred to as Polaroid-PET, consisting of a detector equipped with a layer of horizontal Polaroid to filter scintillation photons with vertical polarization. This makes it possible to improve the spatial resolution of PET scanners based on monolithic crystals. First, a detector module based on a lutetium-yttrium orthosilicate monolithic crystal with 10 mm thickness and silicon photomultipliers (SiPMs) was implemented in the GEANT4 Monte Carlo toolkit. Subsequently, a layer of Polaroid was inserted between the crystal and the SiPMs. Two preclinical PET scanners based on ten detector modules with and without Polaroid were simulated. The performance of the proposed detector modules and corresponding PET scanner for the two configurations (with and without Polaroid) was assessed using standard performance parameters, including spatial resolution, sensitivity, optical photon ratio detected for positioning, and image quality. The detector module fitted with Polaroid led to higher spatial resolution (1.05 mm FWHM) in comparison with a detector without Polaroid (1.30 mm FHWM) for a point source located at the center of the detector module. From 100% of optical photons produced in the scintillator crystal, 65% and 66% were used for positioning in the detectors without and with Polaroid, respectively. Polaroid-PET resulted in higher axial spatial resolution (0.83 mm FWHM) compared to the scanner without Polaroid (1.01 mm FWHM) for a point source at the center of the field of view (CFOV). The absolute sensitivity at the CFOV was 4.37% and 4.31% for regular and Polaroid-PET, respectively. Planar images of a grid phantom demonstrated the potential of the detector with a Polaroid in distinguishing point sources located at close distances. Our results indicated that Polaroid-PET may improve spatial resolution by filtering the reflected optical photons according to their polarization state, while retaining the high sensitivity expected with monolithic crystal detector blocks.
引用
收藏
页数:12
相关论文
共 19 条
  • [11] Estimating the efficiency and purity for detecting annihilation and prompt photons for positronium imaging with J-PET using toy Monte Carlo simulation
    Das, Manish
    Mryka, Wiktor
    Beyene, Ermias Y.
    Parzych, Szymon
    Sharma, Sushil
    Stepien, Ewa
    Moskal, Pawel
    BIO-ALGORITHMS AND MED-SYSTEMS, 2023, 19 (01) : 87 - 95
  • [12] An Investigation of PET Scan Parameters for Lesion Detection With GE VISTA Small-Animal Scanner Using Monte Carlo Simulation and Multivariate Analysis
    Wu, Tung-Hsin
    Yu, Jhih-An
    Yang, Ching-Ching
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 774 - 782
  • [13] Evaluation of a 3-D Point Spread Function (PSF) Model derived from Monte Carlo Simulation for a small animal PET Scanner
    Yao, Rutao
    Ramachandra, Ranjith M.
    Panse, Ashish
    Balla, Deepika
    Yan, Jianhua
    Carson, Richard E.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [14] Characterization of the scatter component in large axial field-of-view PET scanners: a Monte Carlo simulation study
    Ghabrial, Amir
    Franklin, Daniel
    Zaidi, Habib
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [15] Toward 100 ps Coincidence Time Resolution Using Multiple Timestamps in Depth-Encoding PET Modules: A Monte Carlo Simulation Study
    LaBella, Andy
    Tavernier, Stefaan
    Woody, Craig
    Purschke, Martin
    Zhao, Wei
    Goldan, Amir H.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (05) : 679 - 686
  • [16] Imaging performance evaluation in depth-of-interaction PET with a new method of sinogram generation: A Monte Carlo simulation study
    Xia Yan
    Ma Tianyu
    Liu Yaqiang
    Sun Xishan
    Wang Shi
    Shao Yiping
    NUCLEAR SCIENCE AND TECHNIQUES, 2011, 22 (03) : 144 - 150
  • [17] Effect of Scintillator Crystal Geometry and Surface Finishing on Depth of Interaction Resolution in PET Detectors - Monte Carlo Simulation and Experimental Results using Silicon Photomultipliers
    Cuddy, Sarah
    Reznik, Alla
    Rowlands, John A.
    Taghibakhsh, Farhad
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [18] Prismatoid light guide array for enhanced gamma ray localization in PET: a Monte Carlo simulation study of scintillation photon transport
    LaBella, Andy
    Zhao, Wei
    Lubinsky, Rick
    Goldan, Amir H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (18):
  • [19] Therapy region monitoring based on PET using 478 keV single prompt gamma ray during BNCT: A Monte Carlo simulation study
    Jung, Joo-Young
    Lu, Bo
    Yoon, Do-Kun
    Hong, Key Jo
    Jang, HongSeok
    Liu, Chihray
    Suh, Tae Suk
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (04): : 562 - 567