Pulse-Pressure-Enhancing Controller for Better Physiologic Perfusion of Rotary Blood Pumps Based on Speed Modulation

被引:22
作者
Huang, Feng [1 ]
Ruan, Xiaodong [1 ]
Fu, Xin [1 ]
机构
[1] Zhejiang Univ, State Key Lab Fluid Power Transmiss & Control, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
physiologic control; fuzzy logic; pulse pressure; rotary blood pump; ventricular assist device; HEART-FAILURE PATIENTS; COMPUTER-SIMULATION; PULSATILE PERFUSION; ASSIST DEVICE; FLOW; SYSTEM; MODEL; RECOVERY; SENSOR;
D O I
10.1097/MAT.0000000000000059
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Sufficient pulsation is important for physiologic perfusion if adequate flow is to be guaranteed. A fuzzy control method for rotary blood pumps using active speed modulation is proposed in this article. It maintains the mean aortic pressure to provide sufficient perfusion while it simultaneously enhances the pulse pressure. The controller uses the indices extracted from the aortic pressure as feedback to determine the amplitude and offset of the rectangular speed modulation waveform, which is synchronous with the cardiac cycle. An additional algorithm is included to prevent regurgitation. The controller is tested both in a baroreflex-cardiovascular model and in a preliminary in vitro experiment. Simulation results demonstrate that the controller is able to increase the pulse pressure to approximately 20 mm Hg and at the same time maintains the mean pressure at 100 mm Hg, when heart failure occurs. It is also quite robust under various physiologic disturbances. Experimental results show that the speed modulation can be implemented in real pumps and that the controller is feasible in practice.
引用
收藏
页码:269 / 279
页数:11
相关论文
共 30 条
  • [1] Benefits of pulsatile perfusion on vital organ recovery during and after pediatric open heart surgery
    Alkan, Tijen
    Akcevin, Atif
    Uendar, Akif
    Tuerkoglu, Halil
    Paker, Tufan
    Aytac, Aydin
    [J]. ASAIO JOURNAL, 2007, 53 (06) : 651 - 654
  • [2] Non-invasive estimation of pulsatile flow and differential pressure in an implantable rotary blood pump for heart failure patients
    AlOmari, A. H.
    Savkin, A. V.
    Karantonis, D. M.
    Lim, E.
    Lovell, N. H.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2009, 30 (04) : 371 - 386
  • [3] A blood pressure sensor for long-term implantation
    Bullister, E
    Reich, S
    d'Entremont, P
    Silverman, N
    Sluetz, J
    [J]. ARTIFICIAL ORGANS, 2001, 25 (05) : 376 - 379
  • [4] Minimal sensor count approach to fuzzy logic rotary blood pump flow control
    Casas, Fernando
    Ahmed, Nisar
    Reeves, Andrew
    [J]. ASAIO JOURNAL, 2007, 53 (02) : 140 - 146
  • [5] A sensorless approach to control of a turbodynamic left ventricular assist system
    Choi, S
    Antaki, JF
    Boston, JR
    Thomas, D
    [J]. IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2001, 9 (03) : 473 - 482
  • [6] Choi SJ, 1997, P AMER CONTR CONF, P3714, DOI 10.1109/ACC.1997.609538
  • [7] Cong Peng, 2006, Conf Proc IEEE Eng Med Biol Soc, V2006, P1854
  • [8] Computer simulation of sensorless fuzzy control of a rotary blood pump to assure normal physiology
    Fu, MH
    Xu, LY
    [J]. ASAIO JOURNAL, 2000, 46 (03) : 273 - 278
  • [9] A Pulsatile Control Algorithm of Continuous-Flow Pump for Heart Recovery
    Gao, Bin
    Chang, Yu
    Gu, Kaiyun
    Zeng, Yi
    Liu, Youjun
    [J]. ASAIO JOURNAL, 2012, 58 (04) : 343 - 352
  • [10] Modeling and control of a brushless DC axial flow ventricular assist device
    Giridharan, CA
    Skliar, M
    Olsen, DB
    Pantalos, GM
    [J]. ASAIO JOURNAL, 2002, 48 (03) : 272 - 289