Mass balance-based plant-wide wastewater treatment plant models -: Part 1:: Biodegradability of wastewater organics under anaerobic conditions

被引:0
作者
Wentzel, M. C. [1 ]
Ekama, G. A. [1 ]
Sotemann, S. W. [1 ]
机构
[1] Univ Cape Town, Water Res Grp, Dept Civil Engn, ZA-7701 Cape Town, South Africa
关键词
wastewater treatment; primary settling tank; anaerobic digestion; biodegradability; model validation;
D O I
暂无
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
From an experimental and theoretical investigation of the continuity of wastewater organic chemical oxygen demand ( COD) and nitrogen (N) compounds along the link connecting the primary settling tank (PST) and anaerobic digester ( AD), it was found that the primary sludge ( PS) characteristics, viz. the biodegradable and unbiodegradable soluble and particulate COD and N component concentrations, need to be calculated from mass balances around the PST so that the organic and N concentrations conform to continuity principles, and the influent unbiodegradable particulate organics determined from response of the activated sludge ( AS) system are also unbiodegradable under AD conditions.
引用
收藏
页码:269 / 275
页数:7
相关论文
共 25 条
[1]  
[Anonymous], 1995, 3 IWA
[2]  
[Anonymous], [No title captured]
[3]  
BATSTONE DJ, 2002, 9 INT WAT ASS
[4]  
Copp J., 2004, P AD2004 10 WORLD C, p1362
[5]  
COPP JB, 2003, P 76 ANNWAT ENV FED
[6]  
DOLD PL, 1980, PROG WATER TECHNOL, V12, P47
[7]  
DOLD PL, 1991, 5291 WRC
[8]  
ECKENFELDER WW, 1980, PRINCIPLES WATER QUA
[9]  
Ekama GA, 2006, WATER SA, V32, P277