Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography

被引:79
作者
Santana, Cesar A. [1 ]
Garcia, Ernest V. [1 ]
Faber, Tracy L. [1 ]
Sirineni, Gopi K. R. [1 ]
Esteves, Fabio P. [1 ]
Sanyal, Rupan [1 ]
Halkar, Raghuveer [1 ]
Ornelas, Mario [1 ]
Verdes, Liudmila [1 ]
Lerakis, Stamatios [2 ]
Ramos, Julie J. [2 ]
Aguade-Bruix, Santiago [3 ]
Cuellar, Hugo [4 ]
Candell-Riera, Jaume [5 ]
Raggi, Paolo [1 ,2 ]
机构
[1] Emory Univ, Dept Radiol, Atlanta, GA 30322 USA
[2] Emory Univ, Div Cardiol, Atlanta, GA 30322 USA
[3] Vall Hebron Univ Hosp, Dept Nucl Med, Barcelona, Spain
[4] Vall Hebron Univ Hosp, Dept Radiol, Barcelona, Spain
[5] Vall Hebron Univ Hosp, Dept Cardiol, Barcelona, Spain
关键词
Myocardial perfusion imaging; SPECT; PET imaging; computed tomography (CT); coronary artery disease; diagnostic and prognostic application; ARTERY-DISEASE; AMERICAN-COLLEGE; VALIDATION; SPECT; CT;
D O I
10.1007/s12350-008-9019-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the incremental diagnostic value of fusion images of coronary computed tomography angiography (CTA) and myocardial perfusion imaging (MPI) over MPI alone or MPI and CTA side-by-side to identify obstructive coronary artery disease (CAD > 50% stenosis) using invasive coronary angiography (ICA) as the gold standard. 50 subjects (36 men; 56 +/- A 11 years old) underwent rest-stress MPI and CTA within 12-26 days of each other. CTAs were performed with multi-detector CT-scanners (31 on 64-slice; and 19 on 16-slice). 37 patients underwent ICA while 13 subjects did not because of low (< 5%) pre-test likelihood (LLK) of disease. Three blinded readers scored the images in sequential sessions using (1) MPI alone (2) MPI and CTA side-by-side, (3) fused CTA/MPI images. One or more critical stenoses during ICA were found in 28 patients and non-critical stenoses were found in 9 patients. MPI, side-by-side MPI-CTA, and fused CTA/MPI showed the same normalcy rate (NR:13/13) in LLK subjects. The fusion technique performed better than MPI and MPI and CTA side-by-side for the presence of CAD in any vessel (overall area under the curve (AUC) for fused images: 0.89; P = .005 vs MPI, P = .04 vs side-by-side MPI-CTA) and for localization of CAD to the left anterior descending coronary artery (AUC: 0.82, P < .001 vs MPI; P = .007 vs side-by-side MPI-CTA). There was a non-significant trend for better detection of multi-vessel disease with fusion. Using ICA as the gold standard, fusion imaging provided incremental diagnostic information compared to MPI alone or side-by-side MPI-CTA for the diagnosis of obstructive CAD and for localization of CAD to the left anterior descending coronary artery.
引用
收藏
页码:201 / 211
页数:11
相关论文
共 11 条
[1]   Reduction of truncation artifacts in fan beam transmission imaging using a spatially varying gamma prior [J].
Case, JA ;
Pan, TS ;
King, MA ;
Luo, DS ;
Penney, BC ;
Rabin, MSZ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (06) :2260-2265
[2]   Comparison among tomographic radionuclide ventriculography algorithms for computing left and right ventricular normal limits [J].
De Bondt, Pieter ;
Nichols, Kenneth J. ;
De Winter, Olivier ;
De Sutter, Johan ;
Vanderheyden, Marc ;
Akinboboye, Olakunle O. ;
Diercix, Rudi Andre .
JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (05) :675-684
[3]   ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
FORRESTER, JS .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) :1350-1358
[4]  
Faber TL, 2004, J NUCL MED, V45, P745
[5]   Cardiac image fusion from stand-alone SPECT and CT: Clinical experience [J].
Gaemperli, Oliver ;
Schepis, Tiziano ;
Valenta, Ines ;
Husmann, Lars ;
Scheffel, Hans ;
Duerst, Victor ;
Eberli, Franz R. ;
Luscher, Thomas F. ;
Alkadhi, Hatem ;
Kaufmann, Philipp A. .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (05) :696-703
[6]   Quantitative Tc-99m attenuation-corrected sestamibi SPECT: Development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese population [J].
Grossman, GB ;
Garcia, EV ;
Bateman, TM ;
Heller, GV ;
Johnson, LL ;
Folks, RD ;
Cullom, SJ ;
Galt, JR ;
Case, JA ;
Santana, CA ;
Halkar, RK .
JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (03) :263-272
[7]   Minimizing artifacts resulting from respiratory and cardiac motion by optimization of the transmission scan in cardiac PET/CT [J].
Nye, Jonathon A. ;
Esteves, Fabio ;
Votaw, John R. .
MEDICAL PHYSICS, 2007, 34 (06) :1901-1906
[8]   Integrated single-photon emission computed tomography and computed tomography coronary angiography for the assessment of hemodynamically significant coronary artery lesions [J].
Rispler, Shmuel ;
Keidar, Zohar ;
Ghersin, Eduard ;
Roguin, Ariel ;
Soil, Adrian ;
Dragu, Robert ;
Litmanovich, Diana ;
Frenkel, Alex ;
Aronson, Doron ;
Engel, Ahuva ;
Beyar, Rafael ;
Israel, Ora .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (10) :1059-1067
[9]   ACC AHA guidelines for coronary angiography - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography) [J].
Scanlon, PJ ;
Faxon, DP ;
Audet, AM ;
Carabello, B ;
Dehmer, GJ ;
Eagle, KA ;
Legako, RD ;
Leon, DF ;
Murray, JA ;
Nissen, SE ;
Pepine, CJ ;
Watson, RM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) :1756-1816
[10]   CT of coronary artery disease [J].
Schoepf, UJ ;
Becker, CR ;
Ohnesorge, BM ;
Yucel, EK .
RADIOLOGY, 2004, 232 (01) :18-37