Performance evaluation of ground water-source heat pump system with a fresh air pre-conditioner using ground water

被引:25
作者
Wang, Zhanwei [1 ]
Wang, Lin [1 ]
Ma, Aihua [1 ]
Liang, Kunfeng [1 ]
Song, Zun [1 ]
Feng, Lianwei [1 ]
机构
[1] Henan Univ Sci & Technol, Inst Refrigerat & Air Conditioning, Luoyang 471023, Peoples R China
基金
中国国家自然科学基金;
关键词
Ground water-source heat pump; Pre-conditioner; Energy-saving; Fresh air; Ground water; Energy cascade utilization; ENERGY; QUALITY; INDOOR;
D O I
10.1016/j.enconman.2019.03.061
中图分类号
O414.1 [热力学];
学科分类号
摘要
From the perspective of cascade utilization of low-grade energy stored in the ground water, a new type of ground water-source heat pump (GWHP) system with a fresh air pre-conditioner using the ground water (abbreviated to GWHP-FAP) is proposed in this paper. For the GWHP-FAP, the ground water will be firstly used to cool/heat the fresh air in a pre-conditioner, and then enters the condenser/evaporator of heat pump (HP) unit for the secondary utilization. Thus the low-grade energy stored in the ground water is maximally used, and the energy consumption of the whole HP system and buildings is reduced. The working principle and the air treatment schemes of the GWHP-FAP are described in detail in this paper. To evaluate the performance of the GWHP-FAP, an office building is taken as an example to apply the system, and six typical cities distributed in three different climatic areas in China, i.e., Beijing, Zhengzhou, Wuhan, Chengdu, Changde, Guangzhou, are selected to preliminarily discuss the applicability. The results show that the energy saving performance of the GWHP-FAP is very good. The GWHP-FAP compared with the conventional GWHP, its seasonal energy saving rates are respectively 39.2%, 34.2%, 30.1%, 36.7%, 28.4% and 16.6% for the six typical cities during the cooling mode.
引用
收藏
页码:250 / 261
页数:12
相关论文
共 36 条
[1]  
American Society of Heating, 2008, ASHRAE HDB SYST EQ C
[2]  
[Anonymous], 2012, 507322012 GB MIN HOU
[3]  
ANSI/ASHRAE, 2013, 6212013 ANSIASHRAE
[4]  
Ardehali MM, 2008, ENERG ENG, V105, P44
[5]  
Building energy conservation research center Tsinghua university, 2015, 2015 ANN REP CHIN BU
[6]   Ground source heat pumps as high efficient solutions for building space conditioning and for integration in smart grids [J].
Carvalho, Anabela D. ;
Moura, Pedro ;
Vaz, Gilberto C. ;
de Almeida, Anibal T. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 103 :991-1007
[7]   A holistic passive design approach to optimize indoor environmental quality of a typical residential building in Hong Kong [J].
Chen, Xi ;
Yang, Hongxing ;
Sun, Ke .
ENERGY, 2016, 113 :267-281
[8]  
China Meteorological Administration Tsinghua University, 2005, SPEC MET DAT SET AN
[9]   Some perceptions on typical weather year- from the observations of Hong Kong and Macau [J].
Chow, TT ;
Chan, ALS ;
Fong, KF ;
Lin, Z .
SOLAR ENERGY, 2006, 80 (04) :459-467
[10]   Techno-economic evaluation of multiple energy piles for a ground-coupled heat pump system [J].
Cui, Yuanlong ;
Zhu, Jie ;
Meng, Fanran .
ENERGY CONVERSION AND MANAGEMENT, 2018, 178 :200-216