Gadoxetate Disodium-Enhanced MR Cholangiography for Evaluation of Biliary-Enteric Anastomoses: Added Value Beyond Conventional T2-Weighted Images

被引:4
|
作者
Boraschi, Piero [1 ]
Donati, Francescamaria [1 ]
Pacciardi, Federica [1 ]
Cervelli, Rosa [1 ]
Gigoni, Roberto [1 ]
Porcu, Luca [2 ]
Torri, Valter [2 ]
机构
[1] Pisa Univ Hosp, Dept Diagnost Imaging, Via Paradisa 2, I-56124 Pisa, Italy
[2] Ist Ric Farmacol Mario Negri, Lab Methodol Clin Res, Milan, Italy
关键词
biliary-enteric anastomosis; biliary tract; cholangiography; gadopentetate dimeglumine; gadoxetate disodium; MRI; GD-EOB-DTPA; MAGNETIC-RESONANCE CHOLANGIOGRAPHY; ORTHOTOPIC LIVER-TRANSPLANTATION; CHOLANGIOPANCREATOGRAPHY; SYSTEM; LEAKS;
D O I
10.2214/AJR.18.20626
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to evaluate image quality and reader confidence in MR cholangiography of bile ducts using conventional T2-weighted MR cholangiography alone in comparison with T2-weighted MR cholangiography and gadoxetate disodium-enhanced MR cholangiography in a series of patients with biliary-enteric anastomosis (BEA). SUBJECTS AND METHODS. Fifty patients with BEA and clinically and sonographically suspected complications underwent 1.5-1 MRI. After acquisition of T1- and T2-weighted images, conventional MR cholangiography was performed using 3D fast relaxation fast spin-echo (FRFSE) and single-shot fast spin-echo (SSFSE) T2-weighted sequences (image set 1). In each patient, a 3D fat-suppressed Liver Acquisition with Volume Acceleration (LAVA) sequence was performed before and 15, 20, 25, 30, and 40 minutes after IV administration of 0.1 mL/kg of gadoxetate disodium (Primovist) (image set 2). Two radiologists in consensus evaluated image quality in the anatomic segments of the biliary tract and recorded diagnostic confidence scores for image set 1 alone and image sets 1 and 2 together. MRI findings were compared with postsurgical specimen if surgery was performed, conventional cholangiography, or 12 months of imaging follow-up. RESULTS. A significant improvement in image quality for visualization of all biliary segments was found using gadoxetate disodium-enhanced MR cholangiography in comparison with T2-weighted MR cholangiography alone. Readers judged diagnostic confidence of image set 1 alone and image sets 1 and 2 together as very confident in three and 37 cases, confident in 30 and 11, not confident in 14 and one, and not confident at all in three and 1, respectively. Concordance between image set 1 alone and image sets 1 and 2 together and the reference standard results was present in 23 of 50 cases (46%) and 47 of 50 cases (94%), respectively (p < 0.0001). CONCLUSION. Gadoxetate disodium-enhanced MR cholangiography can improve image quality for visualization of the biliary tract and further enhanced the diagnostic performance of conventional T2-weighted MR cholangiography in the evaluation of patients with BEA.
引用
收藏
页码:W123 / W133
页数:11
相关论文
共 11 条
  • [1] Respiratory-triggered Three-dimensional T2-weighted MR Cholangiography after Injection of Gadoxetate Disodium: Is It Still Reliable?
    Ringe, Kristina I.
    Gupta, Rajan T.
    Brady, Christopher M.
    Massey, Christopher M.
    Hahn, Andreas
    Galanski, Michael
    Merkle, Elmar M.
    Lotz, Joachim
    RADIOLOGY, 2010, 255 (02) : 451 - 458
  • [2] Intrahepatic diffuse periportal enhancement patterns on hepatobiliary phase gadoxetate disodium-enhanced liver MR images: Do they correspond to periportal hyperintense patterns on T2-weighted images?
    Onishi, Hiromitsu
    Theisen, Daniel
    Zachoval, Reinhart
    Reiser, Maximilian F.
    Zech, Christoph J.
    MEDICINE, 2019, 98 (11)
  • [3] The Impact of Gd-Eob-Dtpa-Enhanced MR Cholangiography in Biliary Diseases: Comparison with T2-Weighted MR Cholangiopancreatography
    Ozmen, Evrim
    Algin, Oktay
    Evrimler, Sehnaz
    Arslan, Halil
    BALKAN MEDICAL JOURNAL, 2016, 33 (03) : 275 - 282
  • [4] Additional values of high-resolution gadoxetic acid-enhanced MR cholangiography for evaluating the biliary anatomy of living liver donors: Comparison with T2-weighted MR cholangiography and conventional gadoxetic acid-enhanced MR cholangiography
    Kang, Hyo-Jin
    Lee, Jeong Min
    Yoon, Jeong Hee
    Joo, Ijin
    Chang, Won
    Suh, Kyung-Suk
    Lee, Kwang-Woong
    Yi, Nam-Joon
    Han, Joon Koo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (01) : 152 - 159
  • [5] Non-invasive detection of biliary leaks using Gd-EOB-DTPA-enhanced MR cholangiography: comparison with T2-weighted MR cholangiography
    Kantarci, Mecit
    Pirimoglu, Berhan
    Karabulut, Nevzat
    Bayraktutan, Ummugulsum
    Ogul, Hayri
    Ozturk, Gurkan
    Aydinli, Bulent
    Kizrak, Yesim
    Eren, Suat
    Yilmaz, Sinan
    EUROPEAN RADIOLOGY, 2013, 23 (10) : 2713 - 2722
  • [6] Non-invasive detection of biliary leaks using Gd-EOB-DTPA-enhanced MR cholangiography: comparison with T2-weighted MR cholangiography
    Mecit Kantarcı
    Berhan Pirimoglu
    Nevzat Karabulut
    Ummugulsum Bayraktutan
    Hayri Ogul
    Gurkan Ozturk
    Bulent Aydinli
    Yesim Kizrak
    Suat Eren
    Sinan Yilmaz
    European Radiology, 2013, 23 : 2713 - 2722
  • [7] 3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors
    Larry Cai
    Benjamin M. Yeh
    Antonio C. Westphalen
    John Roberts
    Zhen J. Wang
    Abdominal Radiology, 2017, 42 : 842 - 850
  • [8] 3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors
    Cai, Larry
    Yeh, Benjamin M.
    Westphalen, Antonio C.
    Roberts, John
    Wang, Zhen J.
    ABDOMINAL RADIOLOGY, 2017, 42 (03) : 842 - 850
  • [9] MRI Assessment of Biliary Ductal Obstruction: Is There Added Value of T1-Weighted Gadolinium-Ethoxybenzyl-Diethylenetriamine Pentaacetic Acid-Enhanced MR Cholangiography?
    Reiner, Caecilia S.
    Merkle, Elmar M.
    Bashir, Mustafa R.
    Walle, Nicholas L.
    Nazeer, Hamid K.
    Gupta, Rajan T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (01) : W49 - W56
  • [10] Diagnostic value of dynamic contrast-enhanced MRI for unilocular cystic-type ameloblastomas with homogeneously bright high signal intensity on T2-weighted or STIR MR images
    Hisatomi, Miki
    Yanagi, Yoshinobu
    Konouchi, Hironobu
    Matsuzaki, Hidenobu
    Takenobu, Toshihiko
    Unetsubo, Teruhisa
    Asaumi, Jun-ichi
    ORAL ONCOLOGY, 2011, 47 (02) : 147 - 152