Effect of a contact lens on mouse retinal in vivo imaging: Effective focal length changes and monochromatic aberrations

被引:34
作者
Zhang, Pengfei [1 ]
Mocci, Jacopo [2 ]
Wahl, Daniel J. [3 ]
Meleppat, Ratheesh Kumar [1 ]
Manna, Suman K. [1 ]
Quintavalla, Martino [2 ]
Muradore, Riccardo [4 ]
Sarunic, Marinko, V [3 ]
Bonora, Stefano [2 ]
Pugh Jr, Edward N. [1 ,5 ]
Zawadzki, Robert J. [1 ,5 ]
机构
[1] Univ Calif Davis, Dept Cell Biol & Human Anat, UC Davis Eye Pod Small Anim Ocular Imaging Lab, 4320 Tupper Hall, Davis, CA 95616 USA
[2] CNR, Inst Photon & Nanotechnol, Via Trasea 7, I-35131 Padua, Italy
[3] Simon Fraser Univ, Engn Sci, Burnaby, BC V5A 1S6, Canada
[4] Univ Verona, Dept Comp Sci, Verona, Italy
[5] Univ Calif Davis, Dept Ophthalmol & Vis Sci, UC Davis Eye Ctr, 4860 Y St,Suite 2400, Sacramento, CA 95817 USA
关键词
Contact lens; Effective focal length; Mouse eye aberration; Adaptive optics; Scanning laser ophthalmoscope; OPTICAL COHERENCE TOMOGRAPHY; ADAPTIVE-OPTICS; RESOLUTION; EYE; MODELS; RAT; OCT;
D O I
10.1016/j.exer.2018.03.027
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
For in vivo mouse retinal imaging, especially with Adaptive Optics instruments, application of a contact lens is desirable, as it allows maintenance of cornea hydration and helps to prevent cataract formation during lengthy imaging sessions. However, since the refractive elements of the eye (cornea and lens) serve as the objective for most in vivo retinal imaging systems, the use of a contact lens, even with 0 Dpt. refractive power, can alter the system's optical properties. In this investigation we examined the effective focal length change and the aberrations that arise from use of a contact lens. First, focal length changes were simulated with a Zemax mouse eye model. Then ocular aberrations with and without a 0 Dpt. contact lens were measured with a Shack-Hartmann wavefront sensor (SHWS) in a customized AO-SLO system. Total RMS wavefront errors were measured for two groups of mice (14-month, and 2.5-month-old), decomposed into 66 Zernike aberration terms, and compared. These data revealed that vertical coma and spherical aberrations were increased with use of a contact lens in our system. Based on the ocular wavefront data we evaluated the effect of the contact lens on the imaging system performance as a function of the pupil size. Both RMS error and Strehl ratios were quantified for the two groups of mice, with and without contact lenses, and for different input beam sizes. These results provide information for determining optimum pupil size for retinal imaging without adaptive optics, and raise critical issues for design of mouse optical imaging systems that incorporate contact lenses.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 40 条
  • [1] Computational adaptive optics for broadband optical interferometric tomography of biological tissue
    Adie, Steven G.
    Graf, Benedikt W.
    Ahmad, Adeel
    Carney, P. Scott
    Boppart, Stephen A.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (19) : 7175 - 7180
  • [2] Artal P, 2001, J VIS, V1
  • [3] Variational analysis of the mouse and rat eye optical parameters
    Bawa, Gurinder
    Tkatchenko, Tatiana V.
    Avrutsky, Ivan
    Tkatchenko, Andrei V.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2013, 4 (11): : 2585 - 2595
  • [4] Time Course of Cold Cataract Development in Anesthetized Mice
    Bermudez, Maria A.
    Vicente, Ana F.
    Romero, Maria C.
    Arcos, Miguel D.
    Abalo, Jose M.
    Gonzalez, Francisco
    [J]. CURRENT EYE RESEARCH, 2011, 36 (03) : 278 - 284
  • [5] In vivo fluorescent imaging of the mouse retina using adaptive optics
    Biss, David P.
    Sumorok, Daniel
    Burns, Stephen A.
    Webb, Robert H.
    Zhou, Yaopeng
    Bifano, Thomas G.
    Cote, Daniel
    Veilleux, Israel
    Zamiri, Parisa
    Lin, Charles P.
    [J]. OPTICS LETTERS, 2007, 32 (06) : 659 - 661
  • [6] Wavefront correction and high-resolution in vivo OCT imaging with an objective integrated multi-actuator adaptive lens
    Bonora, Stefano
    Jian, Yifan
    Zhang, Pengfei
    Zam, Azhar
    Pugh, Edward N., Jr.
    Zawadzki, Robert J.
    Sarunic, Marinko V.
    [J]. OPTICS EXPRESS, 2015, 23 (17): : 21931 - 21941
  • [7] AN ANALYTIC, GRADIENT INDEX SCHEMATIC LENS AND EYE FOR THE RAT WHICH PREDICTS ABERRATIONS FOR FINITE PUPILS
    CAMPBELL, MCW
    HUGHES, A
    [J]. VISION RESEARCH, 1981, 21 (07) : 1129 - 1148
  • [8] Castejón-Mochón JF, 2002, VISION RES, V42, P1611, DOI 10.1016/S0042-6989(02)00085-8
  • [9] Fabricating customized hydrogel contact lens
    Childs, Andre
    Li, Hao
    Lewittes, Daniella M.
    Dong, Biqin
    Liu, Wenzhong
    Shu, Xiao
    Sun, Cheng
    Zhang, Hao F.
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [10] Clemens Alt, 2012, IN VIVO TRACKING HEM