Flux measurements of NH3, N2O and CO2 using dual beam FTIR spectroscopy and the flux-gradient technique

被引:48
作者
Griffith, DWT [1 ]
Galle, B
机构
[1] Univ Wollongong, Dept Chem, Wollongong, NSW 2522, Australia
[2] Swedish Environm Res Inst, S-40258 Gothenburg, Sweden
关键词
carbon dioxide; nitrous oxide; ammonia; optical subtraction; FTIR; flux-gradient;
D O I
10.1016/S1352-2310(99)00368-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We describe the application of a dual beam Fourier transform infrared (FTIR) spectrometer and sampling system for simultaneous measurements of fluxes of several trace gases between the earth's surface and the atmosphere. The spectrometer is based on a commercial dual-output FTIR spectrometer with two long-path absorption cells, fully automated gas handling, data acquisition and quantitative spectrum analysis. The spectrometer may be operated in single or dual beam (optical subtraction) modes; the advantages and disadvantages of the two modes are tested and discussed. Measurements of fluxes of N(2)O, CO(2) and NH(3) from agricultural landscapes were made by the flux-gradient technique in two field trials in Sweden and Denmark in 1993. Fluxes of NH(3) were determined following liquid manuring of a young wheat cl-op in early summer, and N(2)O and CO(2) fluxes were measured from a recently harvested wheat stubble on an unfertilised organic soil in late summer. NH(3) fluxes of more than 5 mu gN m(-2) s(-1) (4 kg ha(-1) d(-1)) were measured a day after fertilisation, decreasing to < 0.5 mu gN m(-2) s(-1) two days later. N(2)O fluxes averaged 42 ngN m(-2) s(-1) (36 g ha(-1) d(-1)) over the six days of measurement and showed no significant diurnal or longer term variability. Minimum fluxes of 500 and 20 ngN m(-2) s(-1) for NH(3) and N(2)O, respectively, were detectable with 20 min rime resolution. The system is readily extendable to CH(4) measurement. Improvement for the future should improve the minimum detectable fluxes. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1087 / 1098
页数:12
相关论文
共 19 条
  • [1] EFFECTS OF DIFFERENTIATED APPLICATIONS OF FERTILIZER N ON LEACHING LOSSES AND DISTRIBUTION OF INORGANIC N IN THE SOIL
    BERGSTROM, L
    BRINK, N
    [J]. PLANT AND SOIL, 1986, 93 (03) : 333 - 345
  • [2] A global high-resolution emission inventory for ammonia
    Bouwman, AF
    Lee, DS
    Asman, WAH
    Dentener, FJ
    VanderHoek, KW
    Olivier, JGJ
    [J]. GLOBAL BIOGEOCHEMICAL CYCLES, 1997, 11 (04) : 561 - 587
  • [3] DOUBLE-BEAM FOURIER SPECTROSCOPY WITH INTERFEROMETRIC BACKGROUND COMPENSATION
    CHANDRASEKHAR, HR
    GENZEL, L
    KUHL, J
    [J]. OPTICS COMMUNICATIONS, 1976, 17 (01) : 106 - 110
  • [4] Nitrous oxide emission from an agricultural field: Comparison between measurements by flux chamber and micrometerological techniques
    Christensen, S
    Ambus, P
    Arah, JRM
    Clayton, H
    Galle, B
    Griffith, DWT
    Hargreaves, KJ
    Klemedtsson, L
    Lind, AM
    Maag, M
    Scott, A
    Skiba, U
    Smith, KA
    Welling, M
    Wienhold, FG
    [J]. ATMOSPHERIC ENVIRONMENT, 1996, 30 (24) : 4183 - 4190
  • [5] DENMEAD OT, 1993, ASA SPEC P, V55, P19
  • [6] FERM M, 1999, UNPUB ACTA AGR SCAND
  • [7] FOWLER D, 1989, LIFE SCI R, V47, P189
  • [8] APPLICATION OF A FOURIER-TRANSFORM IR SYSTEM FOR MEASUREMENTS OF N2O FLUXES USING MICROMETEOROLOGICAL METHODS, AN ULTRALARGE CHAMBER SYSTEM, AND CONVENTIONAL FIELD CHAMBERS
    GALLE, B
    KLEMEDTSSON, L
    GRIFFITH, DWT
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1994, 99 (D8) : 16575 - 16583
  • [9] DOUBLE-BEAM FOURIER SPECTROSCOPY WITH 2 INPUTS AND 2 OUTPUTS
    GENZEL, L
    CHANDRASEKHAR, HR
    KUHL, J
    [J]. OPTICS COMMUNICATIONS, 1976, 18 (03) : 381 - 386
  • [10] Synthetic calibration and quantitative analysis of gas-phase FT-IR spectra
    Griffith, DWT
    [J]. APPLIED SPECTROSCOPY, 1996, 50 (01) : 59 - 70