Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions

被引:661
作者
Schneider, W [1 ]
Bortfeld, T [1 ]
Schlegel, W [1 ]
机构
[1] Deutsch Krebsforschungszentrum, Dept Med Phys, D-69120 Heidelberg, Germany
关键词
D O I
10.1088/0031-9155/45/2/314
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe a new method to convert CT numbers into mass density and elemental weights of tissues required as input for dose calculations with Monte Carlo codes such as EGS4. As a first step, we calculate the CT numbers for 71 human tissues. To reduce the effort for the necessary fits of the CT numbers to mass density and elemental weights, we establish four sections on the CT number scale, each confined by selected tissues. Within each section, the mass density and elemental weights of the selected tissues are interpolated. For this purpose, functional relationships between the CT number and each of the tissue parameters, valid for media which are composed of only two components in varying proportions, are derived. Compared with conventional data fits, no loss of accuracy is accepted when using the interpolation functions. Assuming plausible values for the deviations of calculated and measured CT numbers, the mass density can be determined with an accuracy better than 0.04 g cm(-3). The weights of phosphorus and calcium can be determined with maximum uncertainties of 1 or 2.3 percentage points (pp) respectively. Similar values can be achieved for hydrogen (0.8 pp) and nitrogen (3 pp). For carbon and oxygen weights, errors up to 14 pp can occur. The influence of the elemental weights on the results of Monte Carlo dose calculations is investigated and discussed.
引用
收藏
页码:459 / 478
页数:20
相关论文
共 23 条
[1]   AN ELECTRON-DENSITY CALIBRATION PHANTOM FOR CT-BASED TREATMENT PLANNING COMPUTERS [J].
CONSTANTINOU, C ;
HARRINGTON, JC ;
DEWERD, LA .
MEDICAL PHYSICS, 1992, 19 (02) :325-327
[2]   CT-based Monte Carlo simulation tool for dosimetry planning and analysis [J].
DeMarco, JJ ;
Solberg, TD ;
Smathers, JB .
MEDICAL PHYSICS, 1998, 25 (01) :1-11
[3]   The indirect use of CT numbers to establish material properties needed for Monte Carlo calculation of dose distributions in patients [J].
du Plessis, FCP ;
Willemse, CA ;
Lotter, MG ;
Goedhals, L .
MEDICAL PHYSICS, 1998, 25 (07) :1195-1201
[4]   Orthovoltage radiation therapy treatment planning using Monte Carlo simulation: Treatment of neuroendocrine carcinoma of the maxillary sinus [J].
Gao, WB ;
Raeside, DE .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12) :2421-2433
[5]  
HARTMANN SCL, 1997, 126732 UCRLJC
[6]   THE ELECTRON-DENSITY OF BONE FOR INHOMOGENEITY CORRECTION IN RADIOTHERAPY PLANNING USING CT NUMBERS [J].
HENSON, PW ;
FOX, RA .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (04) :351-359
[7]   ELECTRON-BEAM DOSE CALCULATIONS [J].
HOGSTROM, KR ;
MILLS, MD ;
ALMOND, PR .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) :445-459
[8]  
Jacob C., 1997, THESIS U HEIDELBERG
[9]  
JOHNS HE, 1983, PHYSICS RADIOLOGY
[10]  
Kak A.C. Slaney M., 1999, PRINCIPLES COMPUTERI