Low-dose preview for patient-specific, task-specific technique selection in cone-beam CT

被引:28
作者
Wang, Adam S. [1 ]
Stayman, J. Webster [1 ]
Otake, Yoshito [1 ]
Vogt, Sebastian [2 ]
Kleinszig, Gerhard [2 ]
Khanna, A. Jay [3 ]
Gallia, Gary L. [4 ]
Siewerdsen, Jeffrey H. [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Siemens Healthcare XP Div, D-91052 Erlangen, Germany
[3] Johns Hopkins Univ, Dept Orthopaed Surg, Baltimore, MD 21205 USA
[4] Johns Hopkins Univ, Dept Neurosurg, Baltimore, MD 21205 USA
关键词
cone-beam CT; dose reduction; protocol optimization; quantum noise; electronic noise; image quality; iterative reconstruction; NOISE-POWER SPECTRUM; FLAT-PANEL DETECTOR; X-RAY CT; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; TRANSMISSION TOMOGRAPHY; PEDIATRIC-PATIENTS; RADIATION-THERAPY; SIMULATION TOOL; REDUCTION;
D O I
10.1118/1.4884039
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A method is presented for generating simulated low-dose cone-beam CT (CBCT) preview images from which patient-and task-specific minimum-dose protocols can be confidently selected prospectively in clinical scenarios involving repeat scans. Methods: In clinical scenarios involving a series of CBCT images, the low-dose preview (LDP) method operates upon the first scan to create a projection dataset that accurately simulates the effects of dose reduction in subsequent scans by injecting noise of proper magnitude and correlation, including both quantum and electronic readout noise as important components of image noise in flat-panel detector CBCT. Experiments were conducted to validate the LDP method in both a head phantom and a cadaveric torso by performing CBCT acquisitions spanning a wide dose range (head: 0.8-13.2 mGy, body: 0.8-12.4 mGy) with a prototype mobile C-arm system. After injecting correlated noise to simulate dose reduction, the projections were reconstructed using both conventional filtered backprojection (FBP) and an iterative, model-based image reconstruction method (MBIR). The LDP images were then compared to real CBCT images in terms of noise magnitude, noise-power spectrum (NPS), spatial resolution, contrast, and artifacts. Results: For both FBP and MBIR, the LDP images exhibited accurate levels of spatial resolution and contrast that were unaffected by the correlated noise injection, as expected. Furthermore, the LDP image noise magnitude and NPS were in strong agreement with real CBCT images acquired at the corresponding, reduced dose level across the entire dose range considered. The noise magnitude agreed within 7% for both the head phantom and cadaveric torso, and the NPS showed a similar level of agreement up to the Nyquist frequency. Therefore, the LDP images were highly representative of real image quality across a broad range of dose and reconstruction methods. On the other hand, naive injection of uncorrelated noise resulted in strong underestimation of the true noise, which would lead to overly optimistic predictions of dose reduction. Conclusions: Correlated noise injection is essential to accurate simulation of CBCT image quality at reduced dose. With the proposed LDP method, the user can prospectively select patient-specific, minimum-dose protocols (viz., acquisition technique and reconstruction method) suitable to a particular imaging task and to the user's own observer preferences for CBCT scans following the first acquisition. The method could provide dose reduction in common clinical scenarios involving multiple CBCT scans, such as image-guided surgery and radiotherapy. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:14
相关论文
共 52 条
[1]  
Barrett H. H., 2003, Foundations of Image Science
[2]  
Benson TM, 2010, IEEE NUCL SCI CONF R, P3169, DOI 10.1109/NSSMIC.2010.5874386
[3]   Addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: an example application to X-ray CT of the brain [J].
Britten, AJ ;
Crotty, M ;
Kiremidjian, H ;
Grundy, A ;
Adam, EJ .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (916) :323-328
[4]  
Chen G.-H., 2006, P SOC PHOTO-OPT INS, V6142
[5]   Geometric calibration of a mobile C-arm for intraoperative cone-beam CT [J].
Daly, M. J. ;
Siewerdsen, J. H. ;
Cho, Y. B. ;
Jaffray, D. A. ;
Irish, J. C. .
MEDICAL PHYSICS, 2008, 35 (05) :2124-2136
[6]   Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype [J].
Daly, M. J. ;
Siewerdsen, J. H. ;
Moseley, D. J. ;
Jaffray, D. A. ;
Irish, J. C. .
MEDICAL PHYSICS, 2006, 33 (10) :3767-3780
[7]   Distance-driven projection and backprojection in three dimensions [J].
De Man, B ;
Basu, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2463-2475
[8]   Ordered subsets algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :2835-2851
[9]   Monotonic algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (09) :801-814
[10]  
Fahrig R, 1997, AM J NEURORADIOL, V18, P1507