Scanning of parallel-plate ionization chamber and diamond detector for measurements of water-dose profiles in the vicinity of a narrow x-ray microbeam

被引:0
作者
Nariyama, Nobuteru [1 ]
机构
[1] Japan Synchrotron Radiat Res Inst, Light Source Div, Kouto 1-1-1, Sayo, Hyogo 6795198, Japan
关键词
diamond detector; GafChromic film; ionization chamber; Monte Carlo; x-ray microbeam; HIGH-ENERGY PHOTON; REFERENCE DOSIMETRY; RADIATION-THERAPY; BEAMS; PERTURBATION; FIELDS;
D O I
10.1002/mp.12596
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Scanning of dosimeters facilitates dose distribution measurements with fine spatial resolutions. This paper presents a method of conversion of the scanning results to water-dose profiles and provides an experimental verification. Methods: An Advanced Markus chamber and a diamond detector were scanned at a resolution of 6 mu m near the beam edges during irradiation with a 25-mu m-wide white narrow x-ray beam from a synchrotron radiation source. For comparison, GafChromic films HD-810 and HD-V2 were also irradiated. The conversion procedure for the water dose values was simulated with Monte Carlo photon-electron transport code as a function of the x-ray incidence position. This method was deduced from nonstandard beam reference-dosimetry protocols used for high-energy x-rays. Results: Among the calculated nonstandard beam correction factors, P-wall, which is the ratio of the absorbed dose in the sensitive volume of the chamber with water wall to that with a polymethyl methacrylate wall, was found to be the most influential correction factor in most conditions. The total correction factor ranged from 1.7 to 2.7 for the Advanced Markus chamber and from 1.15 to 1.86 for the diamond detector as a function of the x-ray incidence position. The water dose values obtained with the Advanced Markus chamber and the HD-810 film were in agreement in the vicinity of the beam, within 35% and 18% for the upper and lower sides of the beam respectively. The beam width obtained from the diamond detector was greater, and the doses out of the beam were smaller than the doses of the others. Conclusions: The comparison between the Advanced Markus chamber and HD-810 revealed that the dose obtained with the scanned chamber could be converted to the water dose around the beam by applying nonstandard beam reference-dosimetry protocols. (C) 2017 American Association of Physicists in Medicine.
引用
收藏
页码:6654 / 6660
页数:7
相关论文
共 18 条
[1]   A new formalism for reference dosimetry of small and nonstandard fields [J].
Alfonso, R. ;
Andreo, P. ;
Capote, R. ;
Huq, M. Saiful ;
Kilby, W. ;
Kjaell, P. ;
Mackie, T. R. ;
Palmans, H. ;
Rosser, K. ;
Seuntjens, J. ;
Ullrich, W. ;
Vatnitsky, S. .
MEDICAL PHYSICS, 2008, 35 (11) :5179-5186
[2]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[3]  
[Anonymous], PROG NUCL SCI TECH
[4]   Ionization chamber-based reference dosimetry of intensity modulated radiation beams [J].
Bouchard, H ;
Seuntjens, J .
MEDICAL PHYSICS, 2004, 31 (09) :2454-2465
[5]   Detector dose response in megavoltage small photon beams. I. Theoretical concepts [J].
Bouchard, Hugo ;
Seuntjens, Jan ;
Duane, Simon ;
Kamio, Yuji ;
Palmans, Hugo .
MEDICAL PHYSICS, 2015, 42 (10) :6033-6047
[6]   Ionization chamber gradient effects in nonstandard beam configurations [J].
Bouchard, Hugo ;
Seuntjens, Jan ;
Carrier, Jean-Francois ;
Kawrakow, Iwan .
MEDICAL PHYSICS, 2009, 36 (10) :4654-4663
[7]   Wall correction factors, Pwall, for thimble ionization chambers [J].
Buckley, LA ;
Rogers, DWO .
MEDICAL PHYSICS, 2006, 33 (02) :455-464
[8]   Dosimetric characterization of a synthetic single crystal diamond detector in clinical radiation therapy small photon beams [J].
Ciancaglioni, I. ;
Marinelli, Marco ;
Milani, E. ;
Prestopino, G. ;
Verona, C. ;
Verona-Rinati, G. ;
Consorti, R. ;
Petrucci, A. ;
De Notaristefani, F. .
MEDICAL PHYSICS, 2012, 39 (07) :4493-4501
[9]   The influence of small field sizes, penumbra, spot size and measurement depth on perturbation factors for microionization chambers [J].
Crop, F. ;
Reynaert, N. ;
Pittomvils, G. ;
Paelinck, L. ;
De Wagter, C. ;
Vakaet, L. ;
Thierens, H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :2951-2969
[10]   Small fields:: Nonequilibrium radiation dosimetry [J].
Das, Indra J. ;
Ding, George X. ;
Ahnesjo, Anders .
MEDICAL PHYSICS, 2008, 35 (01) :206-215