Nexfin Noninvasive Continuous Blood Pressure Validated Against Riva-Rocci/Korotkoff

被引:168
作者
Schattenkerk, Daan W. Eeftinck [2 ]
van Lieshout, Johannes J. [2 ,3 ]
van den Meiracker, Anton H. [4 ]
Wesseling, Karel R. [1 ]
Blanc, Stephane [1 ]
Wieling, Wouter [2 ]
van Montfrans, Gert A. [2 ]
Settels, Jos J. [1 ]
Wesseling, Karel H. [1 ]
Westerhof, Berend E. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, BMEYE BV, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Internal Med, NL-1105 AZ Amsterdam, Netherlands
[3] AMC Ctr Heart Failure Res, Lab Clin Cardiovasc Physiol, Amsterdam, Netherlands
[4] Erasmus Univ, Erasmus Med Ctr, Dept Internal Med, Rotterdam, Netherlands
关键词
FINGER ARTERIAL-PRESSURE; SOCIETY-OF-HYPERTENSION; RECONSTRUCTION; CUFF; VARIABILITY; GUIDELINES; FINAPRES; EXERCISE;
D O I
10.1038/ajh.2008.368
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND The Finapres methodology offers continuous measurement of blood pressure (BP) in a noninvasive manner. The latest development using this methodology is the Nexfin monitor. The present study evaluated the accuracy of Nexfin noninvasive arterial pressure (NAP) compared with auscultatory BP measurements (Riva-Rocci/Korotkoff, RRK). METHODS In supine subjects NAP was compared to RRK, performed by two observers using an electronic stethoscope with double earpieces. Per subject, three NAP-RRK differences were determined for systolic and diastolic BP, and bias and precision of differences were expressed as median (25th, 75th percentiles). Within-subject precision was defined as the (25th, 75th percentiles) after removing the average individual difference. RESULTS A total of 312 data sets of NAP and RRK for systolic and diastolic BP from 104 subjects (aged 18-95 years, 54 males) were compared. RRK systolic BP was 129 (115,150), and diastolic BP was 80 (72,89), NAP-RRK differences were 5.4 (-1.7, 11.0) mm Hg and -2.5 (-7.6, 2.3) mm Hg for systolic and diastolic BP, respectively; within-subject precisions were (-2.2, 2.3) and (-1.6, 1.5) mm Hg, respectively. CONCLUSION Nexfin provides accurate measurement of BP with good within-subject precision when compared to RRK.
引用
收藏
页码:378 / 383
页数:6
相关论文
共 38 条
[1]  
*AAMI, 2002, AM NAT STAND MAN EL
[2]   Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger [J].
Bogert, LWJ ;
van Lieshout, JJ .
EXPERIMENTAL PHYSIOLOGY, 2005, 90 (04) :437-446
[3]   Reconstruction of brachial pressure from finger arterial pressure during orthostasis [J].
Bogert, LWJ ;
Harms, MPM ;
Pott, F ;
Secher, NH ;
Wesseling, KH ;
van Lieshout, JJ .
JOURNAL OF HYPERTENSION, 2004, 22 (10) :1873-1880
[4]   THE RELIABILITY OF NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT IN PATIENTS WITH BOTH HYPERTENSION AND VASCULAR-DISEASE [J].
BOS, WJW ;
IMHOLZ, BPM ;
VANGOUDOEVER, J ;
WESSELING, KH ;
VANMONTFRANS, GA .
AMERICAN JOURNAL OF HYPERTENSION, 1992, 5 (08) :529-535
[5]   PSEUDOHYPERTENSION AND THE MEASUREMENT OF BLOOD-PRESSURE [J].
BOS, WJW ;
VANGOUDOEVER, J ;
WESSELING, KH ;
RONGEN, GAPJM ;
HOEDEMAKER, G ;
LENDERS, JWM ;
VANMONTFRANS, GA .
HYPERTENSION, 1992, 20 (01) :26-31
[6]   INFLUENCE OF SHORT-TERM BLOOD-PRESSURE VARIABILITY ON BLOOD-PRESSURE DETERMINATIONS [J].
BOS, WJW ;
VANGOUDOEVER, J ;
VANMONTFRANS, GA ;
WESSELING, KH .
HYPERTENSION, 1992, 19 (06) :606-609
[7]   Reconstruction of brachial artery pressure from noninvasive finger pressure measurements [J].
Bos, WJW ;
vanGoudoever, J ;
vanMontfrans, GA ;
vandenMeiracker, AH ;
Wesseling, KH .
CIRCULATION, 1996, 94 (08) :1870-1875
[8]   Guidelines on management (diagnosis and treatment) of syncope [J].
Brignole, M ;
Alboni, P ;
Benditt, D ;
Bergfeldt, L ;
Blanc, JJ ;
Thomsen, PEB ;
van Dijk, JG ;
Fitzpatrick, A ;
Hohnloser, S ;
Janousek, J ;
Kapoor, W ;
Kenny, RA ;
Kulakowski, P ;
Moya, A ;
Raviele, A ;
Sutton, R ;
Theodorakis, G ;
Wieling, W .
EUROPEAN HEART JOURNAL, 2001, 22 (15) :1256-1306
[9]  
ELVANTASPINAR A, 2003, J HYPERTENS, P21
[10]   NONINVASIVE BLOOD-PRESSURE MONITORING DURING HEAD-UP TILT USING THE PENAZ PRINCIPLE [J].
FRIEDMAN, DB ;
JENSEN, FB ;
MATZEN, S ;
SECHER, NH .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (07) :519-522