共 50 条
A non-enzymatic glucose sensor based on Ni/PANI coaxial nanowire arrays
被引:7
|作者:
Wang, Hongzhi
[1
]
Qiu, Jianrui
[1
]
Sun, Shaofeng
[2
]
Zhang, Weiguo
[1
]
Yao, Suwei
[1
]
机构:
[1] Tianjin Univ, Sch Chem Engn & Technol, Dept Appl Chem, Tianjin 300350, Peoples R China
[2] Imperial Oil Co Ltd, Calgary, AB, Canada
关键词:
NANOPARTICLES;
PERFORMANCE;
COMPOSITE;
ELECTRODE;
CU;
NANOCOMPOSITES;
NANOTUBES;
D O I:
10.1007/s10854-021-05495-4
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
Ni/PANI coaxial nanowire arrays were prepared by electrochemical deposition using porous anodic alumina as a template. The samples were characterized by scanning electron microscope, transmission electron microscope, X-ray diffraction and Fourier transform infrared spectrometer. The morphology results showed that the outer diameter and wall thickness of Ni/PANI coaxial nanowires were about 100 nm and 20 nm respectively and the PANI nanotubes were completely filled with the Ni nanowires. Cyclic voltammetry (C-V) and chronoamperometry (I-t) showed that Ni/PANI coaxial nanowires can be used as good electrode materials for non-enzymatic glucose sensors. The electrode of Ni/PANI coaxial nanowires has high sensitivity (76.8 mu A mM(-1) cm(-2)), low detection limit (10 mu M) and wide linear range (0-7 mM) (R-2 = 0.982), as well as good selectivity and stability.
引用
收藏
页码:7751 / 7764
页数:14
相关论文