Numerical investigation of slender reinforced concrete and steel-concrete composite columns at normal and high temperatures using sectional analysis and moment-curvature approach

被引:15
作者
Stefan, Radek [1 ]
Sura, Josef [1 ]
Prochazka, Jaroslav [1 ]
Kohoutkova, Alena [1 ]
Wald, Frantisek [2 ]
机构
[1] Czech Tech Univ, Fac Civil Engn, Dept Concrete & Masonry Struct, Thakurova 7, Prague 16629 6, Czech Republic
[2] Czech Tech Univ, Fac Civil Engn, Dept Steel & Timber Struct, Thakurova 7, Prague 16629 6, Czech Republic
关键词
Slender columns; Concrete; Composite columns; Fire; Sectional analysis; Moment-curvature approach; Numerical analysis; FIRE RESISTANCE; NONLINEAR-ANALYSIS; TUBULAR COLUMNS; ZONE METHOD; BEHAVIOR; BEAMS; CALCULATE; ELEMENT; DESIGN; MODEL;
D O I
10.1016/j.engstruct.2019.03.071
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the paper, a numerical procedure for investigation of slender reinforced concrete columns and steel-concrete composite columns at normal and high temperatures is presented. The procedure is based on sectional analysis and moment-curvature approach. Its applicability is illustrated on validation examples in which the results obtained by the simulations are compared with the test data given in literature. It is shown that the procedure provides sufficiently accurate results. The procedure was implemented in an in-house MATLAB code. The code is employed for the calculation of the examples presented in the paper. The code was also included in freely available scientific computer programs. The procedure is applicable for normal and high temperature conditions and for columns of symmetrical cross-sections of any type and shape. It is applicable in connection with any type of temperature-time curve, heat transfer model, and material models.
引用
收藏
页码:285 / 305
页数:21
相关论文
共 84 条
[1]   RECALCULATION OF LABORATORY TESTS WITH THE EXTENDED ZONE METHOD [J].
Achenbach, Marcus ;
Morgenthal, Guido .
APPLICATIONS OF STRUCTURAL FIRE ENGINEERING, 2017,
[2]   Extension of the Zone Method of Eurocode 2 for reinforced concrete columns subjected to standard fire [J].
Achenbach, Marcus ;
Morgenthal, Guido .
JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2016, 7 (02) :82-96
[3]   Proposal of a new method in EN1994-1-2 for the fire design of concrete-filled steel tubular columns [J].
Albero, V. ;
Espinos, A. ;
Romero, M. L. ;
Hospitaler, A. ;
Bihina, G. ;
Renaud, C. .
ENGINEERING STRUCTURES, 2016, 128 :237-255
[4]  
Allen DE, 1974, 416 NAT RES COUNC CA
[5]  
Anderberg Y., 2008, Proceedings of the Fifth International Conference on Structures in Fire (SiF'08), P253
[6]  
[Anonymous], THESIS
[7]  
[Anonymous], 2004, EN 1992-1-2: Eurocode 2: Design of Concrete Structures - Part 1-2: General Rules - Structural Fire Design
[8]  
[Anonymous], 2005, Eurocode 3: Design of Steel Structures, Part 1-2: General Rules - Structural Fire Design
[9]  
[Anonymous], 2002, EN 1991-1-2
[10]  
[Anonymous], 2015, MATLAB VERS 8 6 0 R2