The combined concentric-ring and sector-vortex phased array for MRI guided ultrasound surgery

被引:38
作者
Fjield, T
Hynynen, K
机构
[1] Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston
关键词
D O I
10.1109/58.655641
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
MRI guided ultrasound surgery requires small surgical equipment volumes to facilitate the treatment of larger patients in the limited space of a conventional MRI magnet. In addition, large focal volumes are required to reduce the treatment time of large tumors. The concentric-ring array is capable of moving the focus in one dimension, and previous studies have shown that a circular array composed of radial sectors is capable of producing enlarged focal volumes. These two array designs may be combined to create an array that is capable of both enlarging the focus and moving the focus along the axis of the array. Simulations were performed to predict the performance and capabilities of various combined array designs by using numerical routines to calculate the acoustic power field, temperature distribution, and accumulated thermal dose. The results shown predict that the combined array can create necrosed tissue volumes over 30 times larger than the concentric-ring array while maintaining focal range. The simulation results were verified with an experimental array consisting of 13 rings and 4 sectors. In addition, simulations were performed where multiple focal patterns were cycled in the time domain to create an optimized heating pattern characterized by uniform thermal dose over the volume of the lesion. Such heating patterns resulted in a 40 degrees C lower maximum temperature compared to single mode sonications while producing the same necrosed tissue volume, and yielded a rate of necrosis of 26.4 cm(3)/h.
引用
收藏
页码:1157 / 1167
页数:11
相关论文
共 19 条
[1]   TRANSIENT FIELDS OF CONCAVE ANNULAR ARRAYS [J].
ARDITI, M ;
FOSTER, FS ;
HUNT, JW .
ULTRASONIC IMAGING, 1981, 3 (01) :37-61
[2]   EFFECTS OF PHYSICAL PARAMETERS ON HIGH-TEMPERATURE ULTRASOUND HYPERTHERMIA [J].
BILLARD, BE ;
HYNYNEN, K ;
ROEMER, RB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (04) :409-420
[3]   DESIGN AND EXPERIMENTAL EVALUATION OF ARM INTRACAVITARY ULTRASOUND PHASED-ARRAY SYSTEM FOR HYPERTHERMIA [J].
BUCHANAN, MT ;
HYNYNEN, K .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (12) :1178-1187
[4]   CONCENTRIC-RING AND SECTOR-VORTEX PHASED-ARRAY APPLICATORS FOR ULTRASOUND HYPERTHERMIA [J].
CAIN, CA ;
UMEMURA, S .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :542-551
[5]   FOCUSED US SYSTEM FOR MR IMAGING-GUIDED TUMOR ABLATION [J].
CLINE, HE ;
HYNYNEN, K ;
WATKINS, RD ;
ADAMS, WJ ;
SCHENCK, JF ;
ETTINGER, RH ;
FREUND, WR ;
VETRO, JP ;
JOLESZ, FA .
RADIOLOGY, 1995, 194 (03) :731-737
[6]   THE EFFECT OF VARIOUS PHYSICAL PARAMETERS ON THE SIZE AND SHAPE OF NECROSED TISSUE VOLUME DURING ULTRASOUND SURGERY [J].
DAMIANOU, C ;
HYNYNEN, K .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 95 (03) :1641-1649
[7]  
DOHUU JP, 1981, P IEEE ULTR S, P705
[8]   Ultrasound surgery using multiple sonications - Treatment time considerations [J].
Fan, XB ;
Hynynen, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (04) :471-482
[9]   A parametric study of the concentric-ring transducer design for MRI guided ultrasound surgery [J].
Fjield, T ;
Fan, XB ;
Hynynen, K .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 100 (02) :1220-1230
[10]   THE THRESHOLD FOR THERMALLY SIGNIFICANT CAVITATION IN DOG THIGH MUSCLE INVIVO [J].
HYNYNEN, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :157-169