An ultrasensitive non-enzymatic amperometric glucose sensor based on a Cu-coated nanoporous gold film involving co-mediating

被引:64
作者
Guo, Man-man [1 ]
Wang, Peng-shu [1 ]
Zhou, Chao-hui [1 ]
Xia, Yue [1 ]
Huang, Wei [1 ]
Li, Zelin [1 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Natl & Local Joint Engn Lab New Petrochem Mat & F, Key Lab Chem Biol & Tradit Chinese Med Res,Minist, Changsha 410081, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Non-enzymatic sensor; Glucose; Nanoporous gold film; Cu coating; Electron mediator; Co-mediating; ELECTROCATALYTIC ACTIVITY; ELECTROCHEMICAL DETECTION; TRICHLOROACETIC-ACID; FACILE FABRICATION; NANOPARTICLES; SURFACE; BIOSENSORS; AU; AG; PRECIPITATION;
D O I
10.1016/j.snb.2014.07.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we constructed an ultrasensitive non-enzymatic amperometric glucose sensor based on a Cu-coated nanoporous gold film (Cu/NPGF) for the first time, which comprised two pairs of electron mediators, Cu(II)/Cu(III) and Au/Au(I). The nanoporous gold film with high roughness (R=136) was prepared by anodic potential step and the very thin Cu coating into/on the nanoporous Au was electrodeposited at constant current. In comparison with electrodeposited Cu on a smooth gold surface and with the nanoporous Au, the prepared Cu/NPGF showed significantly enhanced electrocatalytic activity for the oxidation of glucose around 0.1 V due to its nanoporous structure and the pronounced co-mediating of Cu(II)/Cu(III) and Au/Au(I), as well as their coupling Cu(III) + Au = Cu(II)+Au(I). The Cu functionalized NPGF electrode also exhibited an extraordinary performance in sensing glucose with a wide linear range (2 mu M-8.11 mM), short response time (3 s), ultrasensitivity (3643 mu AmM-1 cm(-2)), low detection limit (0.59 mu M), good anti-interference and anti-toxicity, long-term stability (over 3 weeks), and satisfactory quantification of glucose concentration in human serum. We expect that functionalization of nanoporous gold films will provide a new platform for electrochemical sensors. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:388 / 395
页数:8
相关论文
共 74 条
[1]   Wide Linear-Range Detecting Nonenzymatic Glucose Biosensor Based on CuO Nanoparticles Inkjet-Printed on Electrodes [J].
Ahmad, Rafiq ;
Vaseem, Mohammad ;
Tripathy, Nirmalya ;
Hahn, Yoon-Bong .
ANALYTICAL CHEMISTRY, 2013, 85 (21) :10448-10454
[2]   A Nafion-free non-enzymatic amperometric glucose sensor based on copper oxide nanoparticles-graphene nanocomposite [J].
Alizadeh, Taher ;
Mirzagholipur, Shabnam .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 :438-447
[3]  
[Anonymous], 1937, IND ENG CHEM ANAL ED, DOI DOI 10.1021/AC50105A015
[4]   Electrochemistry at nanoporous interfaces: new opportunity for electrocatalysis [J].
Bae, Je Hyun ;
Han, Ji-Hyung ;
Chung, Taek Dong .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2012, 14 (02) :448-463
[5]   Enzyme-free glucose sensor based on a three-dimensional gold film electrode [J].
Bai, Yu ;
Yang, Weiwei ;
Sun, Ying ;
Sun, Changqing .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) :471-476
[6]   Bifunctional Au-Fe3O4 nanopartides for protein separation [J].
Bao, Jie ;
Chen, Wei ;
Liu, Taotao ;
Zhu, Yulin ;
Jin, Peiyuan ;
Wang, Leyu ;
Liu, Junfeng ;
Wei, Yongge ;
Li, Yadong .
ACS NANO, 2007, 1 (04) :293-298
[7]  
BROOKS SL, 1987, BIOSENSORS, V3, P45
[8]  
Burke L.D., ELECTROCHIM ACTA, V37
[9]   MEDIATION OF OXIDATION REACTIONS AT NOBLE-METAL ANODES BY LOW-LEVELS OF INSITU GENERATED HYDROXY SPECIES [J].
BURKE, LD ;
ODWYER, KJ .
ELECTROCHIMICA ACTA, 1989, 34 (12) :1659-1664
[10]   Photoluminescence properties of spark-processed CuO [J].
Chang, SS ;
Lee, HJ ;
Park, HJ .
CERAMICS INTERNATIONAL, 2005, 31 (03) :411-415