Potentiometric Determination of La(III) Using Chitosan Modified Carbon Paste Electrode with An experimental Design

被引:19
|
作者
Rajabi, Negar [1 ]
Masrournia, Mahboubeh [1 ]
Abedi, Mohamadreza [2 ]
机构
[1] Islamic Azad Univ, Dept Chem, Mashhad Branch, Mashhad, Razavi Khorasan, Iran
[2] Islamic Azad Univ, Dept Appl Chem, Quchan Branch, Quchan, Iran
来源
CHEMICAL METHODOLOGIES | 2020年 / 4卷 / 05期
关键词
Lanthanum selective electrode; Multi-walled carbon nanotubes; Chitosan; Modified carbon paste electrode; MEMBRANE-ELECTRODE; VOLTAMMETRIC SENSOR; FOLIC-ACID; LIQUID; PHARMACEUTICALS; NANOSTRUCTURE; CROWN;
D O I
10.22034/chemm.2020.109975
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, D-optimal mixture design was applied as an experimental design to screen and optimize the effect of the composition of a carbon paste on its performance. In this study, chitosan was offered as a ligand for the determination of La(III) with the carbon paste electrode. In the fabricated sensor, the greatest nernstian slope was achieved on the optimized mixture composition by experimental design: 60.00% w/w powder graphite, 1.53% w/w multi-walled carbon nanotubes (MWCNTs), 29.79% w/w paraffin oil, and 8.68% w/w chitosan. MWCNT was used for increasing the electrode response to La(III). The quadratic fitting pattern based on D-optimal model was used to find the desirability functions of the suggested design to assess the cross-interferences and the interactions between the factors. The fabricated sensor for determining the La(III) ions demonstrated a maximum nernstian slope equal to 19.70 mV.decade-1 along a linear range from 1.0x10(-6) to 1.0x10(-2) mol/L-1 and detection limit of 10(-6) mol/L-1. The designed sensor was successfully tested in the pH range of 2-9 with suitable selectivity, fast response time (about 30 s) and long lifetime (over 2 months) was obtained without any deviation. The offered electrode was used successfully as an indicator in the potentiometric titration of La(III) with EDTA. Copyright (C) 2020 by SPC (Sami Publishing Company)
引用
收藏
页码:660 / 670
页数:11
相关论文
共 50 条
  • [41] Gallamine-tetraphenylborate-modified carbon paste electrode for the potentiometric determination of gallamine triethiodide (Flaxedil)
    Abbas, MN
    Mostafa, GAE
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (04) : 819 - 826
  • [42] Chemically Modified Carbon Paste Electrode for the Potentiometric Determination of Dicylomine Hydrochloride in Batch and in FIA Conditions
    H. Ibrahim
    Y. M. Issa
    Hazem M. Abu-Shawish
    Analytical Sciences, 2004, 20 : 911 - 916
  • [43] The electrochemical oxidation of pentachlorophenol and its sensitive determination at chitosan modified carbon paste electrode
    Xu, Junhui
    Wang, Yazhen
    Qiu, Hongxin
    Zhang, Yumin
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (06) : 531 - 536
  • [44] The electrochemical oxidation of pentachlorophenol and its sensitive determination at chitosan modified carbon paste electrode
    Junhui Xu
    Yazhen Wang
    Hongxin Qiu
    Yumin Zhang
    Russian Journal of Electrochemistry, 2014, 50 : 531 - 536
  • [45] Determination of Atomoxetine Hydrochloride in Biological Fluids Using Potentiometric Carbon Paste Electrode Modified by TiO2 Nanoparticles
    Abu Shawish, Hazem M.
    Tamous, Hassan
    Saadeh, Salman M.
    Tbaza, Ahmad
    ACTA CHIMICA SLOVENICA, 2018, 65 (04) : 811 - 822
  • [46] Determination of Trihexyphenidyl hydrochloride drug in tablets and urine using a potentiometric carbon paste electrode
    Abu Shawish, Hazem M.
    Elhabiby, Mahmoud
    Abu Aziz, Hadeel S.
    Saadeh, Salman M.
    Tbaza, Ahmad
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 235 : 18 - 26
  • [47] Potentiometric Determination of Chlorpromazine HCl Using Carbon Paste Electrode in Pure and Pharmaceutical Preparations
    Frag, Eman Y. Z.
    Zayed, M. A.
    Omar, M. M.
    Elashery, Sally E. A.
    Mohamed, Gehad G.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (01): : 650 - 662
  • [48] Differential Pulse Voltammetric Determination of Montelukast in Tablets and Human Plasma by Using Chitosan Modified Carbon Paste Electrode
    Yildiz, Gulcemal
    Aydogmus, Zeynep
    Kauffmann, Jean-Michel
    ELECTROANALYSIS, 2013, 25 (07) : 1796 - 1802
  • [49] A VOLTAMMETRIC TECHNIQUE USING A MODIFIED CARBON PASTE ELECTRODE FOR THE DETERMINATION OF ACLONIFEN
    Novotny, Vit
    Barek, Jiri
    ECOLOGICAL CHEMISTRY AND ENGINEERING S-CHEMIA I INZYNIERIA EKOLOGICZNA S, 2015, 22 (03): : 451 - 458
  • [50] Determination of Gold by Stripping Voltammetry Using a Modified Carbon Paste Electrode
    A. M. Gevorgyan
    V. V. Vanyukov
    S. V. Vakhnenko
    Journal of Analytical Chemistry, 2002, 57 : 253 - 254