Potentiometric Determination of La(III) Using Chitosan Modified Carbon Paste Electrode with An experimental Design

被引:19
|
作者
Rajabi, Negar [1 ]
Masrournia, Mahboubeh [1 ]
Abedi, Mohamadreza [2 ]
机构
[1] Islamic Azad Univ, Dept Chem, Mashhad Branch, Mashhad, Razavi Khorasan, Iran
[2] Islamic Azad Univ, Dept Appl Chem, Quchan Branch, Quchan, Iran
来源
CHEMICAL METHODOLOGIES | 2020年 / 4卷 / 05期
关键词
Lanthanum selective electrode; Multi-walled carbon nanotubes; Chitosan; Modified carbon paste electrode; MEMBRANE-ELECTRODE; VOLTAMMETRIC SENSOR; FOLIC-ACID; LIQUID; PHARMACEUTICALS; NANOSTRUCTURE; CROWN;
D O I
10.22034/chemm.2020.109975
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, D-optimal mixture design was applied as an experimental design to screen and optimize the effect of the composition of a carbon paste on its performance. In this study, chitosan was offered as a ligand for the determination of La(III) with the carbon paste electrode. In the fabricated sensor, the greatest nernstian slope was achieved on the optimized mixture composition by experimental design: 60.00% w/w powder graphite, 1.53% w/w multi-walled carbon nanotubes (MWCNTs), 29.79% w/w paraffin oil, and 8.68% w/w chitosan. MWCNT was used for increasing the electrode response to La(III). The quadratic fitting pattern based on D-optimal model was used to find the desirability functions of the suggested design to assess the cross-interferences and the interactions between the factors. The fabricated sensor for determining the La(III) ions demonstrated a maximum nernstian slope equal to 19.70 mV.decade-1 along a linear range from 1.0x10(-6) to 1.0x10(-2) mol/L-1 and detection limit of 10(-6) mol/L-1. The designed sensor was successfully tested in the pH range of 2-9 with suitable selectivity, fast response time (about 30 s) and long lifetime (over 2 months) was obtained without any deviation. The offered electrode was used successfully as an indicator in the potentiometric titration of La(III) with EDTA. Copyright (C) 2020 by SPC (Sami Publishing Company)
引用
收藏
页码:660 / 670
页数:11
相关论文
共 50 条
  • [31] Multiwall Carbon Nanotubes Modified Carbon Paste Electrode for Determination of Copper(II) by Potentiometric and Impedimetric Methods
    Mazloum-Ardakani, M.
    Mandegari, A. A.
    Masoum, S.
    Naeimi, H.
    JOURNAL OF NANOSTRUCTURES, 2012, 2 (03) : 333 - 343
  • [32] Anodic stripping voltammetric determination of copper (II) in wastewaters using a carbon paste electrode modified with chitosan
    Janegitz, Bruno Campos
    Marcolino, Luiz Humberto, Jr.
    Fatibello-Filho, Orlando
    QUIMICA NOVA, 2007, 30 (07): : 1673 - 1676
  • [33] Anodic stripping voltammetric determination of mercury in water using a chitosan-modified carbon paste electrode
    Marcolino, Luiz H. Junior
    Janegitz, Bruno C.
    Lourencao, Bruna C.
    Fatibello-Filho, Orlando
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3119 - 3128
  • [34] Pb(II) determination in natural water using a carbon nanotubes paste electrode modified with crosslinked chitosan
    Vicentini, Fernando Campanha
    Silva, Tiago Almeida
    Pellatieri, Allan
    Janegitz, Bruno C.
    Fatibello-Filho, Orlando
    Faria, Ronaldo Censi
    MICROCHEMICAL JOURNAL, 2014, 116 : 191 - 196
  • [35] A Novel Carbon Paste Electrode for Potentiometric Determination of Vanadyl Ion
    Darroudi, Abolfazl
    Eshghi, Hossein
    Rezaeian, Shima
    Chamsaz, Mahmoud
    Bakavoli, Mehdi
    Haghbeen, Kamahldin
    Hosseiny, Akram
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2015, 34 (04): : 89 - 96
  • [36] Determination of chloride (I) by potentiometric titration with carbon paste electrode
    Ren, HX
    Wang, ZH
    Liu, WX
    Li, J
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (04) : 492 - 492
  • [37] Chemically modified carbon paste electrode for the potentiometric determination of dicylomine hydrochloride in batch and in FIA conditions
    Ibrahim, H
    Issa, YM
    Abu-Shawish, HM
    ANALYTICAL SCIENCES, 2004, 20 (06) : 911 - 916
  • [38] Modified carbon paste electrode for potentiometric determination of aluminium ion in spiked real water sample
    Marwa ElBadry Mohamed
    Russian Journal of Electrochemistry, 2016, 52 : 754 - 761
  • [39] Determination of benzotriazole by potentiometric and oscillographic titration with carbon paste electrode
    Zhang, JW
    Yang, QY
    Jiang, FT
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (07) : 867 - 867
  • [40] Modified carbon paste electrode for potentiometric determination of aluminium ion in spiked real water sample
    Mohamed, Marwa ElBadry
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2016, 52 (08) : 754 - 761