Potentiometric Determination of La(III) Using Chitosan Modified Carbon Paste Electrode with An experimental Design

被引:19
|
作者
Rajabi, Negar [1 ]
Masrournia, Mahboubeh [1 ]
Abedi, Mohamadreza [2 ]
机构
[1] Islamic Azad Univ, Dept Chem, Mashhad Branch, Mashhad, Razavi Khorasan, Iran
[2] Islamic Azad Univ, Dept Appl Chem, Quchan Branch, Quchan, Iran
来源
CHEMICAL METHODOLOGIES | 2020年 / 4卷 / 05期
关键词
Lanthanum selective electrode; Multi-walled carbon nanotubes; Chitosan; Modified carbon paste electrode; MEMBRANE-ELECTRODE; VOLTAMMETRIC SENSOR; FOLIC-ACID; LIQUID; PHARMACEUTICALS; NANOSTRUCTURE; CROWN;
D O I
10.22034/chemm.2020.109975
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, D-optimal mixture design was applied as an experimental design to screen and optimize the effect of the composition of a carbon paste on its performance. In this study, chitosan was offered as a ligand for the determination of La(III) with the carbon paste electrode. In the fabricated sensor, the greatest nernstian slope was achieved on the optimized mixture composition by experimental design: 60.00% w/w powder graphite, 1.53% w/w multi-walled carbon nanotubes (MWCNTs), 29.79% w/w paraffin oil, and 8.68% w/w chitosan. MWCNT was used for increasing the electrode response to La(III). The quadratic fitting pattern based on D-optimal model was used to find the desirability functions of the suggested design to assess the cross-interferences and the interactions between the factors. The fabricated sensor for determining the La(III) ions demonstrated a maximum nernstian slope equal to 19.70 mV.decade-1 along a linear range from 1.0x10(-6) to 1.0x10(-2) mol/L-1 and detection limit of 10(-6) mol/L-1. The designed sensor was successfully tested in the pH range of 2-9 with suitable selectivity, fast response time (about 30 s) and long lifetime (over 2 months) was obtained without any deviation. The offered electrode was used successfully as an indicator in the potentiometric titration of La(III) with EDTA. Copyright (C) 2020 by SPC (Sami Publishing Company)
引用
收藏
页码:660 / 670
页数:11
相关论文
共 50 条
  • [1] Selective determination of Cr(III) by modified carbon nanotube paste electrode: a potentiometric study
    Barati, Zahra
    Masrournia, Mahboubeh
    Es'haghi, Zarrin
    Jahani, Moslem
    Ebrahimi, Javad
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2022, 97 (05) : 1234 - 1239
  • [2] Anodic stripping voltammetric determination of mercury in water using a chitosan-modified carbon paste electrode
    Marcolino, Luiz H. Junior
    Janegitz, Bruno C.
    Lourencao, Bruna C.
    Fatibello-Filho, Orlando
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3119 - 3128
  • [3] A novel modified carbon paste electrode for potentiometric determination of mercury(II) ion
    Mashhadizadeh, Mohammad Hossein
    Talakesh, Mehrzad
    Peste, Mahnaz
    Momeni, Ahmad
    Hamidian, Houshang
    Majum, Mohammad
    ELECTROANALYSIS, 2006, 18 (22) : 2174 - 2179
  • [4] New triiodomercurate-modified carbon paste electrode for the potentiometric determination of mercury
    Abbas, MN
    Mostafa, GAE
    ANALYTICA CHIMICA ACTA, 2003, 478 (02) : 329 - 335
  • [5] Potentiometric Determination of Oxymetazoline Hydrochloride Using Modified Carbon Paste Electrodes
    Issa, Yousry M.
    Khalil, Mohamed M.
    Zayed, Sayed I. M.
    Mustafa, Naglaa
    PORTUGALIAE ELECTROCHIMICA ACTA, 2021, 39 (05) : 381 - 392
  • [6] Catalytic determination of perchlorate using a modified carbon paste electrode
    Neuhold, CG
    Kalcher, K
    Cai, XH
    Raber, G
    ANALYTICAL LETTERS, 1996, 29 (10) : 1685 - 1704
  • [7] Anodic stripping voltammetric determination of copper (II) in wastewaters using a carbon paste electrode modified with chitosan
    Janegitz, Bruno Campos
    Marcolino, Luiz Humberto, Jr.
    Fatibello-Filho, Orlando
    QUIMICA NOVA, 2007, 30 (07): : 1673 - 1676
  • [8] Electrocatalytic Determination of Carbidopa and Acetaminophen Using a Modified Carbon Nanotube Paste Electrode
    Moghaddam, Hadi Mahmoudi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (12): : 6557 - 6566
  • [9] Modified carbon paste electrode for potentiometric determination of aluminium ion in spiked real water sample
    Mohamed, Marwa ElBadry
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2016, 52 (08) : 754 - 761
  • [10] Gallamine-tetraphenylborate-modified carbon paste electrode for the potentiometric determination of gallamine triethiodide (Flaxedil)
    Abbas, MN
    Mostafa, GAE
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (04) : 819 - 826