Seismic behavior of masonry-infilled precast concrete frames considering effects of opening

被引:17
作者
Wang, Lei [1 ]
Tang, Zhen-Yun [2 ]
Li, Yue [3 ]
Qian, Kai [4 ]
机构
[1] Guilin Univ Technol, Coll Civil Engn & Architecture, Guilin 541004, Peoples R China
[2] Beijing Univ Technol, Minist Educ, Key Lab Urban Secur & Disaster Engn, Beijing 100124, Peoples R China
[3] Case Western Reserve Univ, Dept Civil Engn, Cleveland, OH 44106 USA
[4] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore, Singapore
基金
芬兰科学院;
关键词
Precast concrete; Reinforced concrete; Infilled masonry wall; Seismic; Experimental study; R/C FRAMES; CONNECTIONS; DESIGN; PERFORMANCE; STRENGTH; TESTS;
D O I
10.1016/j.conbuildmat.2019.03.287
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is commonly accepted that addition of infilled masonry walls (1MW) could enhance the in-plane strength and stiffness of RC frame buildings subjected to seismic loads. However, once the 1MW walls failed, the shear force initially resisted by the IMW has to be transferred to the surrounding frames and may incur shear failure to the frames. Despite the extensive studies carried out in the past decades, studies on the structural performance of masonry infilled precast concrete (PC) frames are few. In this study, eight half-scaled single-story one bay frame were tested subjected to seismic loading, including three reinforced concrete (RC) frames and five PC frames. The investigated PC frames deviates the beam potential plastic hinge zone away from beam-to-beam connection region. The variables investigated in the tests included the types of opening in masonry infill walls and the types of cast-in-place concrete at the connections (normal concrete or steel fiber reinforced concrete). Results indicated that the investigated PC construction method has minimal effects on inelastic behavior and ductility of bare and infilled frames. However, the PC construction method may affect the crack development, especially at the interfaces in between precast and cast-in-place concrete surfaces in the region of the connection. However, the load resisting capacity and ductility was insensitive to the usage of steel fiber reinforced concrete at the connections, especially for bare frames. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:756 / 770
页数:15
相关论文
共 46 条
[1]   Behavior of masonry-infilled nonductile reinforced concrete frames [J].
Al-Chaar, G ;
Issa, M ;
Sweeney, S .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (08) :1055-1063
[2]  
[Anonymous], 2008, ENG STRUCT, DOI DOI 10.1016/J.ENGSTRUCT.2008.01.001
[3]  
[Anonymous], 1998, EV EARTHQ DEM CONCR
[4]  
[Anonymous], 2014, BUILD COD REQ STRUCT
[5]  
[Anonymous], 1991, EFFECTS DEGRADING IN
[6]  
ASCE (American Society of Civil Engineers), 2016, 716 ASCESEI
[7]   Mathematical micromodeling of infilled frames: State of the art [J].
Asteris, P. G. ;
Cotsovos, D. M. ;
Chrysostomou, C. Z. ;
Mohebkhah, A. ;
Al-Chaar, G. K. .
ENGINEERING STRUCTURES, 2013, 56 :1905-1921
[8]   A macro-modelling approach for the analysis of infilled frame structures considering the effects of openings and vertical loads [J].
Asteris, Panagiotis G. ;
Cavaleri, Liborio ;
Di Trapani, Fabio ;
Sarhosis, Vasilis .
STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2016, 12 (05) :551-566
[9]   Pseudodynamic testing of masonry infilled reinforced concrete frame [J].
Buonopane, SG ;
White, RN .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1999, 125 (06) :578-589
[10]   Development and testing of precast concrete beam-to-column connections [J].
Choi, H. -K. ;
Choi, Y. -C. ;
Choi, C. -S. .
ENGINEERING STRUCTURES, 2013, 56 :1820-1835