A new type of variable-frequency radio-frequency quadrupole (RFQ) linac has been constructed as a new preinjector for the RIKEN heavy-ion linac (RILAC). The RFQ resonator, based on a folded-coaxial structure with a movable shorting plate, is compact even in a low frequency region below 20 MHz. It accelerates ions with mass-to-charge ratios of 5.3 to 26.4 in the energy range up to 450 keV per charge, by varying its resonant frequency from 17.4 to 39.0 MHz. Moreover, the power loss is small in the low frequency region; the rf power consumption in cw mode is 7 kW at 17.4 MHz, and it increases to 30 kW at 39.0 MHz at the maximum intervane voltage of 36.8 kV. We initiated this project in 1991, and installed the new preinjector consisting of an electron cyclotron resonance ion source of 18 GHz and this RFQ in 1996. Since the installation, the beam intensity has become larger by more than 1 order of magnitude than that formerly obtained with the Cockcroft-Walton preinjector. Recently, the maximum power of the beam extracted from the RILAC and that from the ring cyclotron has reached 560 W and 2 kW, respectively. (C) 1999 American Institute of Physics. [S0034-6748(99)02812-9].
引用
收藏
页码:4523 / 4531
页数:9
相关论文
共 23 条
[1]   Construction and beam tests of a 25.5 MHz split coaxial RFQ for radioactive nuclei [J].
Arai, S ;
Imanishi, A ;
Niki, K ;
Okada, M ;
Takeda, Y ;
Tojyo, E ;
Tokuda, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 390 (1-2) :9-24
[2]  
BATYGIN Y, 1994, 28 RIKEN, P172
[3]  
Crandall K.R., 1979, P 8 PART ACC C NEW Y, P205
[4]  
*CST GMBH, 1991, MAFIA COLL MAFIA US
[5]  
*CST GMBH, 1994, MAFIA COLL MAFIA US
[6]   THE RADIOFREQUENCY SYSTEM OF THE RIKEN RING CYCLOTRON [J].
FUJISAWA, T ;
OGIWARA, K ;
KOHARA, S ;
OIKAWA, Y ;
YOKOYAMA, I ;
NAGASE, M ;
CHIBA, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (01) :1-11
[7]  
IKEZAWA E, 1991, P 8 S ACC SCI TECHN, P73
[8]  
INABE N, 1994, 28 RIKEN, P166
[9]   IMPROVEMENT OF FREQUENCY VARIABILITY OF THE FOLDED-COAXIAL RADIOFREQUENCY QUADRUPOLE LINAC BY INSTALLING A DETACHABLE STEM IN ITS RESONATOR [J].
KAMIGAITO, O ;
GOTO, A ;
MIYAZAWA, Y ;
CHIBA, T ;
HEMMI, M ;
KASE, M ;
KOHARA, S ;
YANG, Y .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1995, 34 (10) :5799-5800
[10]   DESIGN OF A NEW-TYPE OF VARIABLE-FREQUENCY RADIOFREQUENCY QUADRUPOLE LINAC WITH A FOLDED-COAXIAL RESONATOR [J].
KAMIGAITO, O ;
GOTO, A ;
MIYAZAWA, Y ;
CHIBA, T ;
HEMMI, M ;
KASE, M ;
YANO, Y .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1994, 33 (4A) :L537-L540