Structural health monitoring of a steel stringer bridge with area sensing

被引:19
作者
Zhang, Jian [1 ,2 ]
Hong, Wan [2 ]
Tang, Yongsheng [2 ]
Yang, Caiqian [2 ]
Wu, Gang [1 ,2 ]
Wu, Zhishen [1 ,2 ]
机构
[1] Southeast Univ, Minist Educ, Key Lab C&PC Struct, Nanjing, Jiangsu, Peoples R China
[2] Southeast Univ, Int Inst Urban Syst Engn, Nanjing, Jiangsu, Peoples R China
基金
美国国家科学基金会;
关键词
long-gauge; area sensor; macro-strain; dynamic measurement; structural health monitoring; SUSPENSION BRIDGE; AMBIENT VIBRATION; IDENTIFICATION; SYSTEM; DAMAGE;
D O I
10.1080/15732479.2013.787103
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The Federal Highway Administration Long-term Bridge Performance Programme initiated an International Bridge Study by selecting a steel stringer bridge as a benchmark structure for structural health monitoring. As a part of this programme, the authors studied the application of the Long-Gauge Fibre Bragg Grating (LG-FBG) sensors on this bridge. This paper aims at illustrating the LG-FBG-related state-of-the-art technologies by taking the bridge as the test bed. (1) The concept of the LG-FBG sensor for area sensing is presented. Most fibre optic sensors measure point strains for local monitoring. In contrast, the developed LG-FBG area sensor has a long gauge (e.g. 1-2m), and it can be connected to each other to make a sensor array for distributed strain measuring; (2) spectral analyses of the macro-strain time histories are performed to identify structural frequencies, and the results are compared with those estimated from acceleration measurements; (3) the neutral axis position of the girder of the investigated bridge is estimated from the recorded macro-strain time histories, and the results are compared with those from static truck tests and (4) a modal macro-strain-based damage index is applied for damage detection of the steel stringer bridge.
引用
收藏
页码:1049 / 1058
页数:10
相关论文
共 20 条
[1]   AMBIENT VIBRATION STUDIES OF GOLDEN GATE BRIDGE .1. SUSPENDED STRUCTURE [J].
ABDELGHAFFAR, AM ;
SCANLAN, RH .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1985, 111 (04) :463-482
[2]   Modal macro-strain flexibility methods for damage localization in flexural structures using long-gage FBG sensors [J].
Adewuyi, A. P. ;
Wu, Z. S. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2011, 18 (03) :341-360
[3]  
Ansari F., 2012, J INTEL MAT SYST STR, V18, P879
[4]  
ASCE, 2012, STRUCT ID CONSTR FAC
[5]  
Brownjohn J.M.W., 2009, INT C EXP VIBR AN CI, P93
[6]   Parameter estimation for multiple-input multiple-output modal analysis of large structures [J].
Catbas, FN ;
Brown, DL ;
Aktan, AE .
JOURNAL OF ENGINEERING MECHANICS, 2004, 130 (08) :921-930
[7]   Dynamic testing of Alfred Zampa Memorial Bridge [J].
Conte, Joel P. ;
He, Xianfei ;
Moaveni, Babak ;
Masri, Sami F. ;
Caffrey, John P. ;
Wahbeh, Mazen ;
Tasbihgoo, Farzad ;
Whang, Daniel H. ;
Elgamal, Ahmed .
JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (06) :1006-1015
[8]  
Jeffrey A., 2009, EVALUATION BRIDGE PE
[9]   Multi-stage identification scheme for detecting damage in cablestayed Kap Shui Mun Bridge [J].
Ko, JM ;
Sun, ZG ;
Ni, YQ .
ENGINEERING STRUCTURES, 2002, 24 (07) :857-868
[10]   Development of distributed long-gage fiber optic sensing system for structural health monitoring [J].
Li, Suzhen ;
Wu, Zhishen .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2007, 6 (02) :133-143