Risk factors attributed to failure of ultrasound-guided compression for post-cardiac catheterization femoral artery pseudoaneurysms

被引:7
作者
Shatnawi, Nawaf J. [1 ]
Al-Zoubi, Nabil A. [1 ]
Jarrah, Jadallah [1 ]
Khader, Yousef [2 ]
Heis, Mowafeq [3 ]
Al-Omari, Mamoon H. [3 ]
机构
[1] Jordan Univ Sci & Technol, Dept Surg, POB 3030, Irbid 22110, Jordan
[2] Jordan Univ Sci & Technol, Dept Publ Hlth, Irbid, Jordan
[3] Jordan Univ Sci & Technol, Dept Radiol, Irbid, Jordan
来源
SAGE OPEN MEDICINE | 2019年 / 7卷
关键词
Pseudoaneurysm; ultrasound-guided compression; femoral artery; REPAIR; EXPERIENCE; DIAGNOSIS; CLOSURE;
D O I
10.1177/2050312119843705
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Femoral pseudoaneurysm is the most important access site complication following cardiac catheterization. Ultrasound-guided compression repair is a safe and effective therapeutic modality with variable failure rates and risk factors. The aim of this study was to investigate which factors were associated with a higher incidence of ultrasound-guided compression repair failure for post-cardiac catheterization femoral pseudoaneurysm. Methods: Data were retrospectively collected from medical records at King Abdullah University Hospital during the period from January 2011 to December 2016. A total of 42 patients with post-cardiac catheterization femoral pseudoaneurysm had attempted ultrasound-guided compression repair. Data regarding patients, procedure and aneurysm-related factors were evaluated by univariate analysis and multivariate logistic regression. Results: Ultrasound-guided compression repair failed in 31% of the patients. Patients with body mass index of > 28 kg/m(2), platelet count of <= 180,000/L, time lag (age of aneurysm) of >48 h following puncture time, aneurysmal neck diameter of > 4 mm and communicating tract length of <8 mm were associated with higher rate of ultrasound-guided compression repair failure in the univariate analysis. In the multivariate analysis, time lag (age of aneurysm) > 48 h (odds ratio = 5.7), body mass index > 28 kg/m(2) (odds ratio = 7.8), neck diameter > 4 mm (odds ratio = 14.4) and tract length < 8 mm (odds ratio = 18.6) were significantly associated with ultrasound-guided compression repair failure. Conclusion: Ultrasound-guided compression repair for patients with post-cardiac catheterization femoral pseudoaneurysm was successful in 69% of the patients. Risk factors for failed ultrasound-guided compression repair were as follows: delayed ultrasound-guided compression repair of >48 h, body mass index > 28 kg/m(2), wide neck diameter > 4 mm and short aneurysmal communication tract < 8 mm.
引用
收藏
页数:6
相关论文
共 29 条
  • [1] Iatrogenic femoral artery pseudoaneurysms - A review of current methods of diagnosis and treatment
    Ahmad, F.
    Turner, S. A.
    Torrie, P.
    Gibson, M.
    [J]. CLINICAL RADIOLOGY, 2008, 63 (12) : 1310 - 1316
  • [2] Evaluation of risk factors associated with femoral pseudoaneurysms after cardiac catheterization
    Ates, M
    Sahin, S
    Konuralp, C
    Gullu, U
    Cimen, S
    Kizilay, M
    Gunay, R
    Sensoz, Y
    Akcar, M
    [J]. JOURNAL OF VASCULAR SURGERY, 2006, 43 (03) : 520 - 524
  • [3] Chatterjee T, 1996, CATHETER CARDIO DIAG, V38, P335, DOI 10.1002/(SICI)1097-0304(199608)38:4<335::AID-CCD1>3.0.CO
  • [4] 2-8
  • [5] POSTANGIOGR APHIC FEMORAL-ARTERY PSEUDOANEURYSMS - FURTHER EXPERIENCE THE US-GUIDED COMPRESSION REPAIR
    COLEY, BD
    ROBERTS, AC
    FELLMETH, BD
    VALJI, K
    BOOKSTEIN, JJ
    HYE, RJ
    [J]. RADIOLOGY, 1995, 194 (02) : 307 - 311
  • [6] Ultrasound-guided compression closure of postcatheterization pseudoaneurysms during concurrent anticoagulation: A review of seventy-seven patients
    Dean, SM
    Olin, JW
    Piedmonte, M
    Grubb, M
    Young, JR
    [J]. JOURNAL OF VASCULAR SURGERY, 1996, 23 (01) : 28 - 35
  • [7] Sonographically guided compression repair of pseudoaneurysms: further experience from a single institution
    Eisenberg, L
    Paulson, EK
    Kliewer, MA
    Hudson, MP
    DeLong, DM
    Carroll, BA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (06) : 1567 - 1573
  • [8] POSTANGIOGRAPHIC FEMORAL-ARTERY INJURIES - NONSURGICAL REPAIR WITH US-GUIDED COMPRESSION
    FELLMETH, BD
    ROBERTS, AC
    BOOKSTEIN, JJ
    FREISCHLAG, JA
    FORSYTHE, JR
    BUCKNER, NK
    HYE, RJ
    [J]. RADIOLOGY, 1991, 178 (03) : 671 - 675
  • [9] Ultrasound-guided thrombin injection is the treatment of choice for femoral pseudoaneurysms
    Friedman, SG
    Pellerito, JS
    Scher, L
    Faust, G
    Burke, B
    Safa, T
    [J]. ARCHIVES OF SURGERY, 2002, 137 (04) : 462 - 464
  • [10] Heis Hussein A, 2008, Int J Surg, V6, P214, DOI 10.1016/j.ijsu.2008.03.006