In vitro assays for the diagnosis of IgE-mediated disorders

被引:132
作者
Hamilton, RG [1 ]
Adkinson, NF [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Div Clin Immunol & Allergy, Baltimore, MD 21218 USA
关键词
IgE antibody; diagnosis; serologic assays; basophil; histamine; sulfidoleukotriene; CD63; CD203c; allergy;
D O I
10.1016/j.jaci.2004.06.046
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Advances in technology have provided new laboratory tools for the quantitation of allergen-specific IgE antibodies in serum and on the surface of basophils. This review examines the evolution from qualitative IgE antibody assays of the late 1960s to the present-day, third-generation, automated and quantitative allergen-specific IgE assays. The latest technology trend is toward microarrays in which crude or purified native and recombinant allergens can be spotted in microdot arrays on silica chips to permit extensive panels of specific IgE measurements to be performed with small quantities of serum. Although these technologies hold promise, their diagnostic performance requires further assessment once their technical details have been optimized. Potential abuses of this newer IgE antibody technology include the use of allergosorbent specificities (eg, especially food and drugs) that lack validation, application of IgE antibody measurements in the diagnosis of non-IgE-dependent disorders (eg, aspirin sensitivity), and modification of IgE antibody assays to measure food-specific IgG antibody for which there is no clinical indication. Basophil mediator release assays have evolved to include flow cytometric methods that can quantitatively detect the presence of cell surface-bound allergen-specific IgE antibodies. Assays for histamine and leukotriene C-4 released after in vitro basophil activation are now more accurate and standardized. Current analytic methods for IgE antibodies provide more quantitative and reproducible measurements of IgE than ever before, although still with less sensitivity that traditional skin testing. The current challenge is to translate the quantitative IgE antibody results into a more accurate diagnosis of allergic disease.
引用
收藏
页码:213 / 225
页数:13
相关论文
共 64 条
  • [1] RADIOALLERGOSORBENT TEST - USES AND ABUSES
    ADKINSON, NF
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1980, 65 (01) : 1 - 4
  • [3] ADKINSON NF, 1983, ALLERGY PRINCIPLES P, pCH3
  • [4] WILL DNA CHIP SPEED GENOME INITIATIVE
    BARINAGA, M
    [J]. SCIENCE, 1991, 253 (5027) : 1489 - 1489
  • [5] BENNICH H, 1969, J IMMUNOL, V102, P826
  • [6] In vivo sensitization to purified Hevea brasiliensis proteins in health care workers sensitized to natural rubber latex
    Bernstein, DI
    Biagini, RE
    Karnani, R
    Hamilton, R
    Murphy, K
    Bernstein, C
    Arija, S
    Berendts, B
    Yeang, HY
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2003, 111 (03) : 610 - 616
  • [7] Studies of cell adhesion and flow cytometric analyses of degranulation, surface phenotype, and viability using human eosinophils, basophils, and mast cells
    Bochner, BS
    Sterbinsky, SA
    Saini, SA
    Columbo, M
    MacGlashan, DW
    [J]. METHODS, 1997, 13 (01) : 61 - 68
  • [8] Road signs guiding leukocytes along the inflammation superhighway
    Bochner, BS
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2000, 106 (05) : 817 - 828
  • [9] Marked improvement of the basophil activation test by detecting CD203c instead of CD63
    Boumiza, R
    Monneret, G
    Forissier, MF
    Savoye, J
    Gutowski, MC
    Powell, WS
    Bienvenu, J
    [J]. CLINICAL AND EXPERIMENTAL ALLERGY, 2003, 33 (02) : 259 - 265
  • [10] The basophil activation marker defined by antibody 97A6 is identical to the ectonucleotide pyrophosphatase/phosphodiesterase 3
    Bühring, HJ
    Seiffert, M
    Giesert, C
    Marxer, A
    Kanz, L
    Valent, P
    Sano, K
    [J]. BLOOD, 2001, 97 (10) : 3303 - 3305