2D-GRAPPA-operator for faster 3D parallel MRI

被引:71
作者
Blaimer, Martin
Breuer, Felix A.
Mueller, Matthias
Seiberlich, Nicole
Ebel, Dmitry
Heidemann, Robin M.
Griswold, Mark A.
Jakob, Peter M.
机构
[1] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Cleveland, OH 44106 USA
关键词
3D MRI; phased array; parallel imaging; GRAPPA; GRAPPA-operator;
D O I
10.1002/mrm.21071
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
When using parallel MRI (pMRI) methods in combination with three-dimensional (3D) imaging, it is beneficial to subsample the k-space along both phase-encoding directions because one can then take advantage of coil sensitivity variations along two spatial dimensions. This results in an improved reconstruction quality and therefore allows greater scan time reductions as compared to subsampling along one dimension. In this work we present a new approach based on the generalized autocalibrating partially parallel acquisitions (GRAPPA) technique that allows Fourier-domain reconstructions of data sets that are subsampled along two dimensions. The method works by splitting the 2D reconstruction process into two separate 1D reconstructions. This approach is compared with an extension of the conventional GRAPPA method that directly regenerates missing data points of a 2D subsampled k-space by performing a linear combination of acquired data points. In this paper we describe the theoretical background and present computer simulations and in vivo experiments.
引用
收藏
页码:1359 / 1364
页数:6
相关论文
共 19 条
  • [1] Breuer F, 2005, P 13 ANN M ISMRM MIA
  • [2] BREUER F, 2004, P 21 ANN M ESMRMB CO
  • [3] Generalized SMASH imaging
    Bydder, M
    Larkman, DJ
    Hajnal, JV
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) : 160 - 170
  • [4] Cashen T, 2005, P 13 ANN M ISMRM MIA
  • [5] The SENSE ghost: Field-of-view restrictions for SENSE imaging
    Goldfarb, JW
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (06) : 1046 - 1051
  • [6] Parallel magnetic resonance imaging using the GRAPPA operator formalism
    Griswold, MA
    Blaimer, M
    Breuer, F
    Heidemann, RM
    Mueller, M
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) : 1553 - 1556
  • [7] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210
  • [8] Field-of-view limitations in parallel imaging
    Griswold, MA
    Kannengiesser, S
    Heidemann, RM
    Wang, JM
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) : 1118 - 1126
  • [9] GRISWOLD MA, 2004, P 2 INT WORKSH PAR M
  • [10] VD-AUTO-SMASH imaging
    Heidemann, RM
    Griswold, MA
    Haase, A
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) : 1066 - 1074