Individually preformed titanium mesh implants for a true-to-original repair of orbital fractures

被引:76
作者
Schoen, R. [1 ]
Metzger, M. C. [1 ]
Zizelmann, C. [1 ]
Weyer, N. [1 ]
Schmelzeisen, R. [1 ]
机构
[1] Univ Freiburg, Dept Craniomaxillofacial Surg, D-79106 Freiburg, Germany
关键词
individual preformed mesh; orbital fracture; reconstruction; navigation aided procedure; osteosynthesis template; computer-assisted surgery;
D O I
10.1016/j.ijom.2006.06.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this investigation is to present the results using preoperatively-formed titanium mesh implants for a true-to-original primary repair of extensive orbital floor and medial wall fractures. Individually preformed implants were used to repair extensive orbital floor injuries in 19 patients at the University Hospital, Freiburg. The form of the orbital floor and walls was analysed by preoperative diagnostic CT scan data. The form of the virtual reconstructed orbit was transformed into a model of the orbital cavity by a template machine. Postoperative imaging by or CT scan verified the exact 3D reconstruction of the orbital cavity 'true to original'. None of the patients demonstrated diplopia or enophthalmos postoperatively. Using individually preformed titanium mesh implants, the accuracy of the 3D orbital reconstruction was within a range of 1 nun. The reconstruction using preformed implants proved to be less time consuming, more precise and less invasive, compared to 'free hand' efforts, for the repair of orbital injuries using titanium mesh and calvarial grafts.
引用
收藏
页码:990 / 995
页数:6
相关论文
共 51 条
  • [1] ORBITAL VOLUME MEASUREMENTS IN ENOPHTHALMOS USING 3-DIMENSIONAL CT IMAGING
    BITE, U
    JACKSON, IT
    FORBES, GS
    GEHRING, DG
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1985, 75 (04) : 502 - 507
  • [2] ALLOPLAST MATERIALS IN ORBITAL REPAIR
    BROWNING, CW
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1967, 63 (5P1) : 955 - +
  • [3] Pure orbital blowout fracture: New concepts and importance of medial orbital blowout fracture
    Burm, JS
    Chung, CH
    Oh, SJ
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 103 (07) : 1839 - 1849
  • [4] BURRES SA, 1981, LARYNGOSCOPE, V91, P1881
  • [5] The accuracy of stereolithography in planning craniofacial bone replacement
    Chang, PSH
    Parker, TH
    Patrick, CW
    Miller, MJ
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2003, 14 (02) : 164 - 170
  • [6] ORBITAL BLOWOUT FACTURES - A 10-YEAR SURVEY
    CONVERSE, JM
    SMITH, B
    OBEAR, MF
    WOODSMIT.D
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1967, 39 (01) : 20 - +
  • [7] Single-step fronto-orbital resection and reconstruction with individual resection template and corresponding titanium implant:: a new method of computer-aided surgery
    Eufinger, H
    Wittkampf, ARM
    Wehmöller, M
    Zonneveld, FW
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1998, 26 (06) : 373 - 378
  • [8] Computer-assisted orbital volume measurement in the surgical correction of late enophthalmos caused by blowout fractures
    Fan, XQ
    Li, J
    Zhu, J
    Li, HS
    Zhang, DS
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 19 (03) : 207 - 211
  • [9] Safety of titanium mesh for orbital reconstruction
    Gear, AJL
    Lokeh, A
    Aldridge, JH
    Migliori, MR
    Benjamin, CI
    Schubert, W
    [J]. ANNALS OF PLASTIC SURGERY, 2002, 48 (01) : 1 - 7
  • [10] Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity
    Gellrich, NC
    Schramm, A
    Hammer, B
    Rojas, S
    Cufi, D
    Lagrèze, W
    Schmelzeisen, R
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 110 (06) : 1417 - 1429