Methods for the Real-World Evaluation of Fall Detection Technology: A Scoping Review

被引:43
作者
Broadley, Robert W. [1 ]
Klenk, Jochen [2 ,3 ]
Thies, Sibylle B. [1 ]
Kenney, Laurence P. J. [1 ]
Granat, Malcolm H. [1 ]
机构
[1] Univ Salford, Sch Hlth Sci, Salford M6 6PU, Lancs, England
[2] Robert Bosch Krankenhaus, Dept Clin Gerontol, D-70376 Stuttgart, Germany
[3] Ulm Univ, Inst Epidemiol & Med Biometry, D-89081 Ulm, Germany
关键词
accidental falls; fall detection; real-world; signal analysis; performance measures; wearable sensors; non-wearable sensors; accelerometers; cameras; RISK-FACTORS; DETECTION DEVICE; OLDER-ADULTS; SENSOR; FEAR; PERFORMANCE; SIGNALS; HOME;
D O I
10.3390/s18072060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Falls in older adults present a major growing healthcare challenge and reliable detection of falls is crucial to minimise their consequences. The majority of development and testing has used laboratory simulations. As simulations do not cover the wide range of real-world scenarios performance is poor when retested using real-world data. There has been a move from the use of simulated falls towards the use of real-world data. This review aims to assess the current methods for real-world evaluation of fall detection systems, identify their limitations and propose improved robust methods of evaluation. Twenty-two articles met the inclusion criteria and were assessed with regard to the composition of the datasets, data processing methods and the measures of performance. Real-world tests of fall detection technology are inherently challenging and it is clear the field is in its infancy. Most studies used small datasets and studies differed on how to quantify the ability to avoid false alarms and how to identify non-falls, a concept which is virtually impossible to define and standardise. To increase robustness and make results comparable, larger standardised datasets are needed containing data from a range of participant groups. Measures that depend on the definition and identification of non-falls should be avoided. Sensitivity, precision and F-measure emerged as the most suitable robust measures for evaluating the real-world performance of fall detection systems.
引用
收藏
页数:28
相关论文
共 49 条
[1]   Validation of accuracy of SVM-based fall detection system using real-world fall and non-fall datasets [J].
Aziz, Omar ;
Klenk, Jochen ;
Schwickert, Lars ;
Chiari, Lorenzo ;
Becker, Clemens ;
Park, Edward J. ;
Mori, Greg ;
Robinovitch, Stephen N. .
PLOS ONE, 2017, 12 (07)
[2]  
Baker M, 2016, NATURE, V533, P452, DOI 10.1038/533452a
[3]  
Becker C, 2012, Z GERONTOL GERIATR, V45, P707, DOI 10.1007/s00391-012-0403-6
[4]  
Bloch F., 2011, Annals of Physical and Rehabilitation Medicine, V54, P391, DOI 10.1016/j.rehab.2011.07.962
[5]  
Bourke AK, 2016, IEEE ENG MED BIO, P3712, DOI 10.1109/EMBC.2016.7591534
[6]   Real-World Accuracy and Use of a Wearable Fall Detection Device by Older Adults [J].
Chaudhuri, Shomir ;
Oudejans, Daan ;
Thompson, Hilaire J. ;
Demiris, George .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2015, 63 (11) :2415-2416
[7]   Fall Detection Devices and Their Use With Older Adults : A Systematic Review [J].
Chaudhuri, Shomir ;
Thompson, Hilaire ;
Demiris, George .
JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2014, 37 (04) :178-196
[8]   Enhanced characterization of an accelerometer-based fall detection algorithm using a repository [J].
Chen, Kuang-Hsuan ;
Hsu, Yu-Wei ;
Yang, Jing-Jung ;
Jaw, Fu-Shan .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2017, 45 (04) :382-391
[9]   A Biomechanical Analysis of Ventral Furrow Formation in the Drosophila Melanogaster Embryo [J].
Conte, Vito ;
Ulrich, Florian ;
Baum, Buzz ;
Munoz, Jose ;
Veldhuis, Jim ;
Brodland, Wayne ;
Miodownik, Mark .
PLOS ONE, 2012, 7 (04)
[10]  
Davis J., 2006, ICML 06, DOI 10.1145/1143844.1143874