Adaptive-optics ultrahigh-resolution optical coherence tomography

被引:313
作者
Hermann, B [1 ]
Fernández, EJ
Unterhuber, A
Sattmann, H
Fercher, AF
Drexler, W
Prieto, PM
Artal, P
机构
[1] Med Univ Vienna, Christian Doppler Lab, Dept Phys Med, Vienna, Austria
[2] Univ Murcia, Dept Fis, Lab Opt, Murcia, Spain
关键词
D O I
10.1364/OL.29.002142
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Merging of ultrahigh-resolution optical coherence tomography (UHR OCT) and adaptive optics (AO), resulting in high axial (3 mum) and improved transverse resolution (5-10 mum) is demonstrated for the first time to our knowledge in in vivo retinal imaging. A compact (300 mm X 300 mm) closed-loop AO system, based on a real-time Hartmann-Shack wave-front sensor operating at 30 Hz and a 37-actuator membrane deformable mirror, is interfaced to an UHR OCT system, based on a commercial OCT instrument, employing a compact Ti:sapphire laser with 130-nm bandwidth. Closed-loop correction of both ocular and system aberrations results in a residual uncorrected wave-front rms of 0.1 mum for a 3.68-mm pupil diameter. When this level of correction is achieved, OCT images are obtained under a static mirror configuration. By use of AO, an improvement of the transverse resolution of two to three times, compared with UHR OCT systems used so far, is obtained. A significant signal-to-noise ratio improvement of up to 9 dB in corrected compared with uncorrected OCT tomograms is also achieved. (C) 2004 Optical Society of America.
引用
收藏
页码:2142 / 2144
页数:3
相关论文
共 13 条
[1]   HIGH-RESOLUTION IMAGING OF THE LIVING HUMAN FOVEA - MEASUREMENT OF THE INTERCENTER CONE DISTANCE BY SPECKLE INTERFEROMETRY [J].
ARTAL, P ;
NAVARRO, R .
OPTICS LETTERS, 1989, 14 (20) :1098-1100
[2]   Compensation of corneal aberrations by the internal optics in the human eye [J].
Artal, Pablo ;
Guirao, Antonio ;
Berrio, Esther ;
Williams, David R. .
JOURNAL OF VISION, 2001, 1 (01) :1-8
[3]   In vivo ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Kärtner, FX ;
Pitris, C ;
Boppart, SA ;
Li, XD ;
Ippen, EP ;
Fujimoto, JG .
OPTICS LETTERS, 1999, 24 (17) :1221-1223
[4]   Ultrahigh-resolution ophthalmic optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Ghanta, RK ;
Kärtner, FX ;
Schuman, JS ;
Fujimoto, JG .
NATURE MEDICINE, 2001, 7 (04) :502-507
[5]   Ultrahigh-resolution optical coherence tomography [J].
Drexler, W .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) :47-74
[6]   Membrane deformable mirror for adaptive optics:: performance limits in visual optics [J].
Fernández, EJ ;
Artal, P .
OPTICS EXPRESS, 2003, 11 (09) :1056-1069
[7]   Closed-loop adaptive optics in the human eye [J].
Fernández, EJ ;
Iglesias, I ;
Artal, P .
OPTICS LETTERS, 2001, 26 (10) :746-748
[8]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[9]   Supernormal vision and high-resolution retinal imaging through adaptive optics [J].
Liang, JZ ;
Williams, DR ;
Miller, DT .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) :2884-2892
[10]   Coherence gating and adaptive optics in the eye [J].
Miller, DT ;
Qu, JL ;
Jonnal, RS ;
Thorn, K .
COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VII, 2003, 4956 :65-72