Real-time monitoring of spinal cord blood flow with a novel sensor mounted on a cerebrospinal fluid drainage catheter in an animal model

被引:5
|
作者
Hayatsu, Yukihiro [1 ]
Kawamoto, Shunsuke [1 ]
Matsunaga, Tadao [2 ]
Haga, Yoichi [3 ]
Saiki, Yoshikatsu [1 ]
机构
[1] Tohoku Univ, Dept Cardiovasc Surg, Grad Sch Med, Sendai, Miyagi 9808574, Japan
[2] Tohoku Univ, Micro Syst Integrat Ctr, Sendai, Miyagi 9808574, Japan
[3] Tohoku Univ, Grad Sch Biomed Engn, Sendai, Miyagi 9808574, Japan
来源
关键词
AORTIC-ANEURYSM REPAIR; REDUCES PARAPLEGIA; LIFE EXPECTANCY; THORACIC AORTA; PERFUSION; OPERATIONS; SURGERY; INJURY; PAPAVERINE; PROTECTION;
D O I
10.1016/j.jtcvs.2014.04.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of our study was to develop a novel monitoring system for spinal cord blood flow (SCBF) to test the efficacy of the SCBF sensor in an animal model. Methods: The sensor system consisted of 2 optical fibers, a pedestal for fiber fixation, and a mirror for the laser reflection and was incorporated into a cerebrospinal fluid drainage catheter. In vivo studies were performed in a swine model (n = 10) to measure SCBF during spinal cord ischemia induced by clamping the descending thoracic aorta and supra-aortic neck vessels, when necessary. A temporary low cardiac output model was also created by inflow clamping of the inferior vena cava to analyze the quantitative changes in SCBF during this maneuver. Results: The developed SCBF monitoring catheter placed intrathecally could detect SCBF in all the swine. The SCBF after aortic crossclamping at the fourth intercostal level exhibited diverse changes reproducibly among the swine, with a >25% reduction in SCBF in 5 pigs, an increase in 3, and no significant changes in 2. Consistent reductions were recorded during inferior vena cava occlusion. The mean SCBF decreased by 32% after inferior vena cava occlusion when the cardiac output had decreased by 27%. Conclusions: We have developed a novel SCBF sensor that could detect real-time changes in spinal cord perfusion in a swine model. The device holds promise to detect imminent ischemia or ensure acceptable blood perfusion in the spinal cord and could further enhance our understanding of spinal cord circulation.
引用
收藏
页码:1726 / 1731
页数:6
相关论文
共 50 条
  • [21] A miniaturized piezoresistive flow sensor for real-time monitoring of intravenous infusion
    Hagihghi, Reza
    Razmjou, Amir
    Orooji, Yasin
    Warkiani, Majid E.
    Asadnia, Mohsen
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2020, 108 (02) : 568 - 576
  • [22] Detrimental effects of cerebrospinal fluid pressure elevation on spinal cord perfusion: first-time direct detection in a large animal model
    Haunschild, Josephina
    von Aspern, Konstantin
    Khachatryan, Zara
    Bianchi, Edoardo
    Friedheim, Till
    Wipper, Sabine
    Trepte, Constantin J.
    Ossmann, Susann
    Borger, Michael A.
    Etz, Christian D.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (02) : 286 - 293
  • [23] Blood and cerebrospinal fluid flow oscillations measured with real-time phase-contrast MRI: breathing mode matters
    Maria Marcella Laganà
    Sonia Di Tella
    Francesca Ferrari
    Laura Pelizzari
    Marta Cazzoli
    Noam Alperin
    Ning Jin
    Domenico Zacà
    Giuseppe Baselli
    Francesca Baglio
    Fluids and Barriers of the CNS, 19
  • [24] EFFECTS OF THORACIC AORTIC OCCLUSION AND CEREBROSPINAL-FLUID DRAINAGE ON REGIONAL SPINAL-CORD BLOOD-FLOW IN DOGS - CORRELATION WITH NEUROLOGIC OUTCOME
    BOWER, TC
    MURRAY, MJ
    GLOVICZKI, P
    YAKSH, TL
    HOLLIER, LH
    PAIROLERO, PC
    JOURNAL OF VASCULAR SURGERY, 1989, 9 (01) : 135 - 144
  • [25] Development of modified laser Doppler flowmetry device for real-time monitoring of esophageal mucosal blood flow: a preclinical assessment with an animal model
    Kawarai, Shun-Ichi
    Katahira, Shintaro
    Miyatake, Midori
    Itagaki, Kota
    Tsuruoka, Noriko
    Haga, Yoichi
    Saiki, Yoshikatsu
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (03) : 284 - 292
  • [26] MONITORING OF SPINAL CORD BLOOD FLOW DURING ORTHOPEDIC SURGERY IN AN OVINE MODEL
    Busch, David R.
    Lin, Wei
    Kovarovic, Brandon J.
    Cutrone, Alissa
    Tatka, Jakub
    Yodh, Arjun G.
    Barsi, James
    Floyd, Thomas F.
    ANESTHESIA AND ANALGESIA, 2018, 126 (04): : 751 - 751
  • [27] Blood and cerebrospinal fluid flow oscillations measured with real-time phase-contrast MRI: breathing mode matters
    Lagana, Maria Marcella
    Di Tella, Sonia
    Ferrari, Francesca
    Pelizzari, Laura
    Cazzoli, Marta
    Alperin, Noam
    Jin, Ning
    Zaca, Domenico
    Baselli, Giuseppe
    Baglio, Francesca
    FLUIDS AND BARRIERS OF THE CNS, 2022, 19 (01)
  • [28] Real-time imaging of respiratory effects on cerebrospinal fluid flow in small diameter passageways
    Toger, Johannes
    Andersen, Mads
    Haglund, Olle
    Kylkilahti, Tekla Maria
    Lundgaard, Iben
    Bloch, Karin Markenroth
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (02) : 770 - 786
  • [29] Minimally Invasive Real-Time Monitoring for Rapid and Sensitive Diagnosis of Spinal Cord Injury
    Wang, Chengcheng
    Wang, Cai
    Wang, Minyue
    Wang, Mengyue
    Ni, Qingbin
    Sun, Jingyi
    Sun, Baoliang
    Wang, Ying
    ACS SENSORS, 2024, 9 (10): : 5058 - 5068
  • [30] Real-Time Assessment of Spinal Cord Microperfusion in a Porcine Model of Ischemia/Reperfusion
    Behem, Christoph R.
    Friedheim, Till
    Wipper, Sabine H.
    Pinnschmidt, Hans O.
    Graessler, Michael F.
    Gaeth, Catharina
    Holthusen, Hannes
    Rapp, Adina
    Suntrop, Timo
    Haunschild, Josephina
    Etz, Christian D.
    Trepte, Constantin J. C.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (166): : 1 - 19