Measurements of multiphoton action cross sections for multiphoton microscopy

被引:124
作者
Cheng, Li-Chung [1 ,2 ]
Horton, Nicholas G. [2 ]
Wang, Ke [3 ]
Chen, Shean-Jen [4 ,5 ]
Xu, Chris [2 ]
机构
[1] Natl Cheng Kung Univ, Dept Photon, Tainan 701, Taiwan
[2] Cornell Univ, Sch Appl & Engn Phys, Ithaca, NY 14853 USA
[3] Shenzhen Univ, Coll Optoelect Engn, Minist Educ & Guangdong Prov, Key Lab Optoelect Devices & Syst, Shenzhen 518060, Peoples R China
[4] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 701, Taiwan
[5] Natl Cheng Kung Univ, Adv Optoelect Technol Ctr, Tainan 701, Taiwan
来源
BIOMEDICAL OPTICS EXPRESS | 2014年 / 5卷 / 10期
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
2-PHOTON; BRIGHTNESS; SPECTRA;
D O I
10.1364/BOE.5.003427
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report quantitative measurements of two-, three-, and four-photon excitation action cross sections of several commonly used fluorophores and fluorescent proteins at three different excitation wavelengths of 800 nm, 1300 nm, and 1680 nm. The measured cross section values are consistent with simple quantum mechanic estimations. These values indicate that the optimum repetition rate for deep tissue 3-photon microscopy is approximately 1 to 2 MHz. We further demonstrate that it is feasible to perform 4-photon fluorescence microscopy of GFP labeled microglia in mouse brain in vivo at 1700 nm. 4-photon excitation increases the accessibility of fluorophores at the long wavelength spectral window of 1700 nm. (C)2014 Optical Society of America
引用
收藏
页码:3427 / 3433
页数:7
相关论文
共 24 条
  • [1] Two-photon fluorescence excitation cross sections of biomolecular probes from 690 to 960 nm
    Albota, MA
    Xu, C
    Webb, WW
    [J]. APPLIED OPTICS, 1998, 37 (31) : 7352 - 7356
  • [2] Infrared multiphoton microscopy: subcellular-resolved deep tissue imaging
    Andresen, Volker
    Alexander, Stephanie
    Heupel, Wolfgang-Moritz
    Hirschberg, Markus
    Hoffman, Robert M.
    Friedl, Peter
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 2009, 20 (01) : 54 - 62
  • [3] Effect of excitation wavelength on penetration depth in nonlinear optical microscopy of turbid media
    Balu, Mihaela
    Baldacchini, Tommaso
    Carter, John
    Krasieva, Tatiana B.
    Zadoyan, Ruben
    Tromberg, Bruce J.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (01)
  • [4] Two-photon excitation action cross-sections of the autofluorescent proteins
    Blab, GA
    Lommerse, PHM
    Cognet, L
    Harms, GS
    Schmidt, T
    [J]. CHEMICAL PHYSICS LETTERS, 2001, 350 (1-2) : 71 - 77
  • [5] Dynamics of the microglial/amyloid interaction indicate a role in plaque maintenance
    Bolmont, Tristan
    Haiss, Florent
    Eicke, Daniel
    Radde, Rebecca
    Mathis, Chester A.
    Klunk, William E.
    Kohsaka, Shinichi
    Jucker, Mathias
    Calhoun, Michael E.
    [J]. JOURNAL OF NEUROSCIENCE, 2008, 28 (16) : 4283 - 4292
  • [6] Wavelength dependent damage in biological multi-photon confocal microscopy:: A micro-spectroscopic comparison between femtosecond Ti:sapphire and Cr:forsterite laser sources
    Chen, IH
    Chu, SW
    Sun, CK
    Cheng, PC
    Lin, BL
    [J]. OPTICAL AND QUANTUM ELECTRONICS, 2002, 34 (12) : 1251 - 1266
  • [7] Absolute Two-Photon Absorption Spectra and Two-Photon Brightness of Orange and Red Fluorescent Proteins
    Drobizhev, M.
    Tillo, S.
    Makarov, N. S.
    Hughes, T. E.
    Rebane, A.
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2009, 113 (04) : 855 - 859
  • [8] Drobizhev M, 2011, NAT METHODS, V8, P393, DOI [10.1038/NMETH.1596, 10.1038/nmeth.1596]
  • [9] Characterization of photodamage in coherent anti-Stokes Raman scattering microscopy
    Fu, Y
    Wang, HF
    Shi, RY
    Cheng, JX
    [J]. OPTICS EXPRESS, 2006, 14 (09): : 3942 - 3951
  • [10] Horton NG, 2013, NAT PHOTONICS, V7, P205, DOI [10.1038/nphoton.2012.336, 10.1038/NPHOTON.2012.336]