Effect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes

被引:86
作者
Can, Berrin Zeliha [1 ]
Boncukcuoglu, Recep [2 ]
Yilmaz, Alper Erdem [2 ]
Fil, Baybars Ali [2 ,3 ]
机构
[1] Eighth Reg Directorate State Hydraul Works DSI, Erzurum, Turkey
[2] Ataturk Univ, Fac Engn, Dept Environm Engn, Erzurum, Turkey
[3] Balikesir Univ, Fac Engn, Dept Environm Engn, Balikesir, Turkey
来源
JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING | 2014年 / 12卷
关键词
Arsenic removal; Electrocoagulation; Wastewater treatment; Iron electrode; WASTE-WATER TREATMENT; AQUEOUS-SOLUTIONS; REVERSE-OSMOSIS; DRINKING-WATER; GROUNDWATER; WASTEWATERS; SULFATE;
D O I
10.1186/2052-336X-12-95
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Arsenic contamination of drinking water is a global problem that will likely become more apparent in future years as scientists and engineers measure the true extent of the problem. Arsenic poisoning is preventable though as there are several methods for easily removing even trace amounts of arsenic from drinking water. In the present study, electrocoagulation was evaluated as a treatment technology for arsenic removal from aqueous solutions. The effects of parameters such as initial pH, current density, initial concentration, supporting electrolyte type and stirring speed on removal efficiency were investigated. It has been observed that initial pH was highly effective on the arsenic removal efficiency. The highest removal efficiency was observed at initial pH = 4. The obtained experimental results showed that the efficiency of arsenic removal increased with increasing current density and decreased with increasing arsenic concentration in the solution. Supporting electrolyte had not significant effects on removal, adding supporting electrolyte decreased energy consumption. The effect of stirring speed on removal efficiency was investigated and the best removal efficiency was at the 150 rpm. Under the optimum conditions of initial pH 4, current density of 0.54 mA/cm(2), stirring speed of 150 rpm, electrolysis time of 30 minutes, removal was obtained as 99.50%. Energy consumption in the above conditions was calculated as 0.33 kWh/m(3). Electrocoagulation with iron electrodes was able to bring down 50 mg/L arsenic concentration to less than 10 mu g/L at the end of electrolysis time of 45 minutes with low electrical energy consumption as 0.52 kWh/m(3).
引用
收藏
页数:10
相关论文
共 42 条
[1]  
Alimoradzadeh R, 2012, IRAN J ENVIRON HEALT, V9, DOI [10.1186/1735-2746-9-12, 10.1186/1735-2746-9-38]
[2]   Arsenic(V) removal from aqueous solutions using an anion exchanger derived from coconut coir pith and its recovery [J].
Anirudhan, T. S. ;
Unnithan, Maya R. .
CHEMOSPHERE, 2007, 66 (01) :60-66
[3]   Removal of arsenic from ground water by manganese dioxide-coated sand [J].
Bajpai, S ;
Chaudhuri, M .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1999, 125 (08) :782-784
[4]   Removal of arsenic from aqueous solution using electrocoagulation [J].
Balasubramanian, N. ;
Kojima, Toshinori ;
Basha, C. Ahmed ;
Srinivasakannan, C. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) :966-969
[5]   Removal of arsenic and sulphate from the copper smelting industrial effluent [J].
Basha, C. Ahmed ;
Selvi, S. Josephine ;
Ramasamy, E. ;
Chellammal, S. .
CHEMICAL ENGINEERING JOURNAL, 2008, 141 (1-3) :89-98
[6]  
Benefield LD, 1982, PROCESSES CHEM WATER
[7]   Electrochemical technologies in wastewater treatment [J].
Chen, GH .
SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 38 (01) :11-41
[8]  
Chowdhury Z., 2002, IMPLEMENTATION ARS 1
[9]  
Edwards M, 1994, CHEM ARSENIC REMOVAL
[10]   Evaluation of iron and manganese-coated pumice application for the removal of as(v) from aqueous solutions [J].
Far, Leila Babaie ;
Souri, Bubak ;
Heidari, Masoumeh ;
Khoshnavazi, Roshan .
IRANIAN JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE & ENGINEERING, 2012, 9