Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II)

被引:16
作者
Moyo, Mambo [1 ]
Okonkwo, Jonathan O. [1 ]
Agyei, Nana M. [2 ]
机构
[1] Tshwane Univ Technol, Dept Environm Water & Earth Sci, ZA-0001 Pretoria, South Africa
[2] Univ Limpopo, Dept Chem, ZA-0204 Medunsa, South Africa
关键词
Maize tassel; Carbon paste; Cu(II); Voltammetry; Electrochemical sensor; SMZ-CPE; COPPER; LEAD; PRECONCENTRATION; FLUORESCENCE; REMOVAL; CADMIUM; SENSOR; IONS; IRON;
D O I
10.1007/s10661-014-3739-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The preparation and application of a practical electrochemical sensor for environmental monitoring and assessment of heavy metal ions in samples is a subject of considerable interest. In this paper, a carbon paste electrode modified with maize tassel for the determination of Cu(II) has been proposed. Scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) were used to study morphology and identify the functional groups on the modified electrode, respectively. First, Cu(II) was adsorbed on the carbon paste electrode surface at open circuit and voltammetric techniques were used to investigate the electrochemical performances of the sensor. The electrochemical sensor showed an excellent electrocatalytic activity towards Cu(II) at pH 5.0 and by increasing the amount of maize tassel biomass, a maximum response at 1:2.5 (maize tassel:carbon paste; w/w) was obtained. The electrocatalytic redox current of Cu(II) showed a linear response in the range (1.23 mu M to 0.4 mM) with the correlation coefficient of 0.9980. The limit of detection and current-concentration sensitivity were calculated to be 0.13 (+/- 0.01) mu M and 0.012 (+/- 0.001) mu A/mu M, respectively. The sensor gave good recovery of Cu(II) in the range from 96.0 to 98.0 % when applied to water samples.
引用
收藏
页码:4807 / 4817
页数:11
相关论文
共 42 条
[1]   Phytochelatin modified electrode surface as a sensitive heavy-metal ion biosensor [J].
Adam, V ;
Zehnalek, J ;
Petrlova, J ;
Potesil, D ;
Sures, B ;
Trnkova, L ;
Jelen, F ;
Vitecek, J ;
Kizek, R .
SENSORS, 2005, 5 (1-2) :70-84
[2]   A novel microbial biosensor based on Circinella sp modified carbon paste electrode and its voltammetric application [J].
Alpat, Senol ;
Alpat, Sibel Kilinc ;
Cadirci, Bilge Hilal ;
Yasa, Ihsan ;
Telefoncu, Azmi .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (01) :175-181
[3]   Development of a novel carbon paste electrode containing a natural zeolite for the voltammetric determination of copper [J].
Alpat, SK ;
Yuksel, U ;
Akcay, H .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (02) :130-134
[4]  
[Anonymous], 1987, ANALYST, V112, P199
[5]  
Cesarino I., 2007, ECLET QUIM, V32, P29
[6]   Determination of trace level cadmium in SRM 3280 Multivitamin/Multielement Tablets via isotope dilution inductively coupled plasma mass spectrometry [J].
Christopher, Steven J. ;
Thompson, Robert Q. .
TALANTA, 2013, 116 :18-25
[7]   DETERMINATION OF VERY LOW CONCENTRATIONS OF COPPER, IRON AND LEAD IN HYDROCARBON FUELS BY ATOMIC FLUORESCENCE SPECTROMETRY [J].
COTTON, DH ;
JENKINS, DR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1970, B 25 (06) :283-&
[8]   Recent developments in stripping analysis on microelectrodes [J].
Daniele, Salvatore ;
Baldo, M. Antonietta ;
Bragato, Carlo .
CURRENT ANALYTICAL CHEMISTRY, 2008, 4 (03) :215-228
[9]  
Devnani H., 2013, ENVIRON MONIT ASSESS, P1
[10]   Determination of lead(II) in aqueous solution using carbon nanotubes paste electrodes modified with Amberlite IR-120 [J].
do Nascimento, Marilene Elisa ;
Martelli, Patricia Benedini ;
Furtado, Clascidia Aparecida ;
Santos, Adelina P. ;
Cappa de Oliveira, Luiz Fernando ;
Gorgulho, Honoria de Fatima .
MICROCHIMICA ACTA, 2011, 173 (3-4) :485-493