Insights on limits of detection, precision and accuracy in TXRF analysis of trace and major elements in environmental solid suspensions

被引:21
作者
Espinoza-Quinones, Fernando Rodolfo [1 ]
Modenes, Aparecido Nivaldo [1 ]
dos Santos, Joelmir [1 ]
Obregon, Phallcha Luizar [2 ]
de Pauli, Aline Roberta [1 ]
机构
[1] West Parana State Univ, Postgrad Program, Dept Chem Engn, Campus Toledo,Rua Fac 645, BR-85903000 Toledo, PR, Brazil
[2] Parana West State Univ, Ctr Med & Pharmaceut Sci, Campus Cascavel, BR-85819110 Cascavel, PR, Brazil
关键词
Multi-elemental analysis; Environmental solid matrices; Instrumental sensitivity; Limits of detection; Accuracy and precision; REFLECTION X-RAY; FLUORESCENCE SPECTROMETRY; MULTIELEMENTAL ANALYSIS; HEAVY-METAL; SEDIMENTS; SAMPLES; APPLICABILITY; TISSUES; SERUM; WATER;
D O I
10.1016/j.apradiso.2018.03.016
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this work, the analytical capability of the total reflection X-ray fluorescence technique with the S2 PICOFOX spectrometer was investigated. A set of certified reference materials was prepared as solid particulate for TXRF analysis. Experimental data of sensitivity, limits of detection and recovery for many elements were obtained. Good sensitivity and limits of detection with a good recovery range of around 90-110% were achieved. Thus, the TXRF technique exhibits a good analytical potential for its applicability on different materials.
引用
收藏
页码:80 / 90
页数:11
相关论文
共 41 条
[1]   Stability Monitoring of Pesticide Residues in a Chinese Cabbage Certified Reference Material [J].
Ahn, Seonghee ;
Kim, Byungjoo ;
Hwang, Eujin .
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (04) :1365-1367
[2]  
Beauchaine M, 2013, REV TXRF APPL TRACE
[3]   Analysis of human tissues by total reflection X-ray fluorescence. Application of chemometrics for diagnostic cancer recognition [J].
Benninghoff, L ;
vonCzarnowski, D ;
Denkhaus, E ;
Lemke, K .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (07) :1039-1046
[4]   Heavy metal and trace element concentrations in wheat grains: Assessment of potential non-carcinogenic health hazard through their consumption [J].
Bermudez, Gonzalo M. A. ;
Jasan, Raquel ;
Pla, Rita ;
Luisa Pignata, Maria .
JOURNAL OF HAZARDOUS MATERIALS, 2011, 193 :264-271
[5]   Total reflection X-ray fluorescence as a tool for food screening [J].
Borgese, Laura ;
Bilo, Fabjola ;
Dalipi, Rogerta ;
Bontempi, Elza ;
Depero, Laura E. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 113 :1-15
[6]   Use of epidermis for the monitoring of tissular trace elements in Mediterranean striped dolphins (Stenella coeruleoalba) [J].
Borrell, A. ;
Clusa, M. ;
Aguilar, A. ;
Drago, M. .
CHEMOSPHERE, 2015, 122 :288-294
[7]  
Bruker, 2012, S2 PIC US MAN, P118
[8]  
Bruker, 2011, S2 PIC TXRF SPECTR E
[9]  
Bruker, 2007, 426 XRF BRUK AXS MIC
[10]   ICP-OES assessment of heavy metal contamination in tropical marine sediments: A comparative study of two digestion techniques [J].
Chand, Vimlesh ;
Prasad, Surendra .
MICROCHEMICAL JOURNAL, 2013, 111 :53-61