Reference values for indoor air pollutant concentrations in new, residential buildings in Finland

被引:113
作者
Jarnstrom, H.
Saarela, K.
Kalliokoski, P.
Pasanen, A. -L.
机构
[1] Univ Kuopio, Dept Environm Sci, FIN-70211 Kuopio, Finland
[2] Kuopio Reg Inst Occupat Hlth, FIN-70701 Kuopio, Finland
基金
芬兰科学院;
关键词
indoor air; VOC; formaldehyde; ammonia; reference values; new buildings;
D O I
10.1016/j.atmosenv.2006.06.021
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Eight buildings, representing the present construction practice in Finland, were investigated to create numeric reference data for indoor air quality (IAQ) in new residential buildings. Low-emitting materials according to the "Finnish Classification of Building Materials" were used in all the buildings. The airborne volatile organic compounds (VOCs), formaldehyde, and ammonia concentrations as well as temperature, relative humidity, and the air exchange rate were determined in the newly finished buildings and after 6 and 12 months. Target values for the indoor air concentrations were not generally reached in newly finished buildings. The lowest concentration levels were measured in buildings with mechanical supply and exhaust air systems. Formaldehyde concentrations fulfilled best the target values. The TVOC concentration usually reached the S2/S3-class values within 6 months. However, the ammonia concentration remained above the S3 limit during the whole first year. The concentrations of ammonia and formaldehyde showed seasonal variations, i.e., higher concentrations were measured in summer. The concentrations of individual VOCs generally decreased most strongly during the first 6 months and the final mean concentration levels were generally less than 15 mu g m(-3). As the occupancy period got longer, the VOCs originating from the construction phase were increasingly replaced by new ones. Reference values based on means and on 95 percentiles are presented to facilitate interpretation of the results of measurements done to ensure that proper construction practices have been applied or to investigate IAQ problems. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:7178 / 7191
页数:14
相关论文
共 39 条
[1]   TVOC and health in non-industrial indoor environments - Report from a Nordic scientific consensus meeting at Langholmen in Stockholm, 1996 [J].
Andersson, K ;
Bakke, JV ;
Bjorseth, O ;
Bornehag, CG ;
Clausen, G ;
Hongslo, JK ;
Kjellman, M ;
Kjaergaard, S ;
Levy, F ;
Molhave, L ;
Skerfving, S ;
Sundell, J .
INDOOR AIR, 1997, 7 (02) :78-91
[2]  
[Anonymous], 2004, IARC MON EV CARC RIS
[3]  
Bornehag CG, 2000, P HLTH BUILD 2000 ES, V1, P437
[4]  
*BOVERKET, 2002, BOV BYGGR 2002
[5]   Volatile organic pollutants in new and established buildings in Melbourne, Australia [J].
Brown, SK .
INDOOR AIR, 2002, 12 (01) :55-63
[6]   VOC concentrations measured in personal samples and residential indoor, outdoor and workplace microenvironments in EXPOLIS-Helsinki, Finland [J].
Edwards, RD ;
Jurvelin, J ;
Saarela, K ;
Jantunen, M .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (27) :4531-4543
[7]  
*ERHV BYGG, 1995, BYGN ERHV ET
[8]  
FiSIAQ (Finnish Society of Indoor Air Quality and Climate), 2001, CLASS IND CLIM 2000
[9]  
*GUND VERK BAUUND, 2001, GUID SUST BUILD
[10]   Volatile organic compound concentrations and emission rates in new manufactured and site-built houses [J].
Hodgson, AT ;
Rudd, AF ;
Beal, D ;
Chandra, S .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2000, 10 (03) :178-192